ZE33 Water Heater Gas Leakage and Incomplete Combustion Detection Module


Description:


Water heater gas leakage and incomplete combustion detection module using electrochemical carbon monoxide sensor and combustible gas sensor developed a special detection of gas water heater incomplete combustion and gas leakage module. It uses the electrochemical principle to detect carbon monoxide gas produced by incomplete combustion in the air, and has good selectivity and stability.

Application:

Detection and alarm of gas leakage and incomplete combustion of household gas water heater.

Features:

The module has sound and light alarm output, and PWM digital signal output mode.

Specifications:

ModelZE33RecoveryTime≤30 s
Detection GasCO, CH4Detection RangeCO:0~500ppm CH4:0~5000ppm
Interfering gasAlcohol, etc.Alarm concentrationCO: Alarm 1: 250±50ppm Alarm 2:350±50ppm CH4:8%±3% LEL
OutputPWM
Alarm modeAudible and visual alarmWorking Temperature-10℃~55℃
Working Voltage5V DCWorking Humidity15%-90%RH (non-condensing)
Preheat TimeCO 30s/CH4 3minStorage Temperature-10℃~55℃
Response Time≤60 sLifespan5 years (in air)