Add to Cart
H2S-B1 H2S-BH H2S-B4 Electrochemistry Hydrogen Sulfide Sensor Two-year Life High Current Output For Stationary Hydrogen Sulfide Transmitter
PERFORMANCE:
Sensitivity nA/ppm in 20ppm H2S 300 to 440
Response time t90 (s) from zero to 20ppm H2S < 35
Zero current ppm equivalent in zero air < ± 0.2
Resolution RMS noise (ppm equivalent) < 0.1
Range ppm H2S limit of performance warranty 200
Linearity ppm error at full scale, linear at zero and 20ppm H2S 1
to -8
Overgas range maximum ppm for stable response to gas pulse 500
LIFETIME :
Zero drift ppm equivalent change/year in lab air < 0.05
Sensitivity drift % change/year in lab air, monthly test < 2
Operating life months until 80% original signal (24 month
warranted) > 24
ENVIRONMENTAL :
Sensitivity @ -20°C % (output @ -20°C/output @ 20°C) @ 20ppm 83 to
93
Sensitivity @ 50°C % (output @ 50°C/output @ 20°C) @ 20ppm 102 to
110
Zero @ -20°C ppm equivalent change from 20°C < ± 1
Zero @ 50°C ppm equivalent change from 20°C < ± 1
Size | Φ32.3*16.5 |
Service life | 2 years |
Storage period | 6 months |
Operating temperature | -30 ~ 50℃ |
Working humidity | 15 ~ 90%RH |