Industrial Intelligent Electric Boiler 700KW Intelligent Temperature Control Heating

Brand Name:lincheng
Model Number:LC-L-700kw
Minimum Order Quantity:discussible
Delivery Time:3-10 working days
Payment Terms:L/C, T/T
Place of Origin:Shenyang, Liaoning, China
Contact Now

Add to Cart

Active Member
Location: Shenyang Liaoning China
Address: 20-1 Jiayang Road, Shenbei New District, Shenyang, Liaoning
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

Industrial Intelligent Electric Boiler 700KW Intelligent Temperature Control Heating


Description Of Electric Heater Boiler Heating:


The electric heater boiler uses the electromagnetic induction principle to heat 1L water, and the power consumption is 0.117 degrees. Use an electric heating tube to heat 1L of water, and the power consumption is 0.289 degrees. Compared with the two phases, the electromagnetic induction principle is adopted for heating, and the power saving is about 2.5 times.

Product features: energy saving, environmental protection, low carbon, intelligent, safe and durable.


Electric Heater Boiler Technical Parameter:

Serial numberProduct modelCompanyLC-L-700kw
1Rated powerKW700
2Rated currentA1064
3Heating area7000-10000
4input voltage50HZ380V
5Minimum flow of water pump configurationL/min850
6Hot water yield 50 ℃L/min327.6
7Design thermal efficiency98%
8Maximum water temperature85
9Low temperature protection temperature5
10Overall dimension (length * width * height)mm3500L*1200W*2000H
11Water inlet and outlet interfaceDN100

Technical Description Of Electric Heater Boiler:


1. The circulating water pump shall match the power of the electric heater boiler

The power of the electric heater boiler determines the hot water supply speed. The circulation speed of the water pump must be as close as possible to the hot water supply speed. If the circulation speed of the water pump is too small, the end temperature of the heat pipe network will not meet the heating standard. If the circulation speed of the water pump is too fast, the electric heater boiler will always operate at high power, resulting in a waste of electric energy. This is because too fast water flow will make the return water temperature closer to the outlet water temperature. The electric heater boiler also has to do the action of boiling water, resulting in a waste of electric energy. This is not necessarily the case. The whole cycle of some buildings will be very long. In this case, the whole cycle can be appropriately accelerated.

2. Safety factors shall be considered for the installation position of electric heater boiler

First, try to avoid children's contact. The functions of the electric heater boiler are relatively diversified. Children's misoperation may lead to changes in heating settings. Electric shock can also be caused in the same way. The installation position of the electromagnetic boiler shall be dry and ventilated to avoid installation in the kitchen and toilet. Because there is a risk of being flooded.

3. Irregularly check the water volume and pay attention to supplement

Water leakage in the pipe network is very common. Slight water leakage will not cause damage, but will reduce the heating effect. The electric heater boiler has the function of monitoring water volume, which is generally reflected in the panel warning or the water level gauge. Observe the water level frequently and supplement it in time to save power.

4. Install the exhaust valve

In the sealed pipe network, the heating water will produce a certain amount of gas, and the gas will be filled in the case of water leakage. In order to ensure the stability of the heating effect, it is necessary to install an exhaust valve and exhaust regularly.