Thiamphenicolmilk Raw Milk Testing Kit For Home 96 Tests/Kit For Fresh Milk

Brand Name:Green Spring
Certification:ISO13485,ISO9001
Model Number:LSY-20099
Minimum Order Quantity:1kit
Delivery Time:7~14days
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Shenzhen
Address: Vanke Tianyu Garden,B2-1010, Unit B, Building 9 Longcheng Street Longgang District Shenzhen, China
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

Thiamphenicol Rapid Milk Test Kit 96 Tests/Kit for Fresh Milk


1. Specifications


8 strips/bottle, 12 bottles/kit


2. Thiamphenicol Rapid Milk Test Kit Brief


The Thiamphenicol rapid test strip is used for testing Thiamphenicol residue in fresh milk qualitatively. The whole test only need 6min, east to operate with high sensitivity. This product has cross reaction with Florfenicol.


3. Detection limit: ppb(ug/kg)


NameDetection limit (ppb)
Thiamphenicol0.3~0.5
Florfenicol0.3

4. Thiamphenicol Rapid Milk Test Kit Contents


1Thiamphenicol test strip8strip/bottle
2Red powder micro-well8 micro-well/bottle
3Desiccant2piece/bottle
4Instruction1 piece

5. Principle


The Thiamphenicol rapid test strip is based on competitive inhibition immuno-chromatographic principle. In the flow process, Thiamphenicol or Florfenicol in the sample combined with Thiamphenicol specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Thiamphenicol-BSA conjugate on Test line of NC membrane, lead to the color change of Test line. When the sample has no Thiamphenicol or Florfenicol residue or concentration lower than detection limit, T line is darker then C line; when the concentration is equal to or higher than detection limit, T line is lighter than C line or T line has no color or T line has same color with C line. No matter whether there is Thiamphenicol or Florfenicol residue in sample, C line will appear, it means the test is valid.


6. Operation procedures


6.1 Read the instruction carefully before use. Return test strips and sample into room temperature.
6.2 Take bottles needed from the kit package, take out required microwells, making proper marks, Please use it in 1 hour. Seal the cap of the bottles, avoid moisture.
6.3 Use Micro-pipette to take 200ul of the samples into the microwells, then repeatedly absorb for 5 times, mix the sample with the reagent in the microwells completely until no solid judged by eyes (this is a very important step).
6.4 Incubate at 40±2℃for 3 min. Then insert the strip into micro-well, put the end with MAX down into the liquid.
6.5 Insert the strip into the liquid for 3min, then read the result.


7. Test Result Interpretation


Color depth comparison of T line and C lineResult judgmentResult analysis
T line > C lineNegativeThiamphenicol or Florfenicolresidue is lower than detection limit in sample
T line = C lineWeak positiveThiamphenicol or Florfenicol residue is equal to detection limit in sample
T line < C line or T line is invisiblePositiveThiamphenicol or Florfenicol residue is higher than detection limit in sample
C line is invisibleInvalidThe test strip is invalid, test again


8. Precautions


1) Use the test strip once at room temperature, do not use expired test strips.
2) Cap the bottle immediately after removing the reagent. If the 8 microwells cannot be used at a time, immediately cap the microwells, put them back in the bottle, and store them in an airtight container.
3) Do not touch the white film surface in the middle of the test strip, avoid direct sunlight and direct blowing of fans.
4) The milk sample should be completely liquid without any lumps, sour taste and sedimentation
5) Use the test strip again for a positive result.


9. Specificity


This product has no cross-reaction with quinolones, sulfonamides, tetracyclines, etc.


10. Storage and expiration date


Storage: 2-8 ℃ dark, sealed, dry place, not frozen.
Expiration date: 12 months; production date is on the box.



Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In case of external factors such as the epidemic, the delivery may be delayed)


Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces, which is convenient for customized products.


Q3: How is your factory doing in terms of quality control?
A3: We have nationally certified ISO9001 and ISO13485. Our production process conforms to standard procedures to ensure optimum product quality.


Q4: How to provide after-sales service?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance via video, telephone, etc.


Q5: What is the payment method?
A5: We receive payment by T/T.


Q6: How to ship?
A6: Choose the best shipping method for you by getting quotes from our many cooperative carriers, and also ship according to your requirements.

China Thiamphenicolmilk Raw Milk Testing Kit For Home  96 Tests/Kit For Fresh Milk supplier

Thiamphenicolmilk Raw Milk Testing Kit For Home 96 Tests/Kit For Fresh Milk

Inquiry Cart 0