Bird Flu Subtype H9 Antibody ELISA Test Kit for Poultry 96 Wells/Kit
1. Usage
This kit is used to detect Bird Flu subtype H9 antibody in chicken
serum, to assess antibody condition by Bird Flu subtype H9 vaccine
in chicken farm and assist diagnosis of serological infected
chicken.
2. Principle
The Bird Flu subtype H9 antibody ELISA kit is based on an indirect
enzymatic immunoassay (Indirect ELISA).The antigen is coated on
plates. When a sample serum contains specific antibodies against
virus, they will bind to the antigen on plates. Wash the unbound
antibodies and other components. Then add a specific enzyme
conjugate. After incubation and washing, add the TMB substrate. A
colorimetric reaction will appear, measured by a spectrophotometer
(450 nm).
3. Reagents
1 | H9 antigen coated microplate | 1/2 plate of 96 wells | 7 | Negative control | 0.8/1.6ml |
2 | Enzyme conjugate | 11/22 ml | 8 | Positivecontrol | 0.8/1.6ml |
3 | 10×concentrated washing buffer | 100ml | 9 | Serum dilution plate | 1/2 piece |
4 | Substrate solution | 11/22 ml | 10 | Adhesive film | 2/4 pieces |
5 | Sample dilution | 100ml | 11 | Instruction | 1 piece |
6 | Stopping solution | 11/22ml |
4. Materials required but not provided
1) Micropipettors and disposable tips:
0.5μL~10μL,10μL~100μL,100μL~1000μL
2) 37 ℃ Incubator
3) 96 wells microplate reader
4) Distilled water or deionied water
5) Bottle or microplate washing machine
5. Sample preparation
Take animal whole blood, make serum according to regular methods,
the serum should be clear, have no hemolysis.
6. Preparation of washing buffer
Return washing solution to room temperature before use, if there is
salty crystals, shake to make the crystals dissolve, then use
distilled water or deionized water to dilute it at 10 times. The
diluted washing solution can store for 1 week at 4 ℃.
7. Sample dilution
At serum dilution plate, dilute serum at 1:100 with sample dilution
(for example: 495μL sample dilution + 5μL serum)
Notice: Negative control and Positive control do not need dilute.
Exchange tip after taking sample every time, record the situation
of the sample on plate accurately. Shake the sample evenly before
adding it.
8. Notes
1) All reagents should be adjusted to the room temperature and
shake evenly before using, store at 2-8 ℃after using
2) Do not exchange the reagents from the kits of different lot
numbers to use. Avoid reagent pollution when using.
3) Substrate and stop solution may have excitant to skin and eyes,
pay attention when using.
4) Do not expose TMB (Substrate B) to light and avoid it contact
with antioxidants.
5) The wells should avoid damp or touching water after unsealing
(Put the un-using microplate back to bag with dehydrator in 2~8
℃soon )
6) Deal all waste reasonable before dumping to avoid pollution.
7) Strictly adhere to instruction to get best result. All procedure
including pipetting, timing and washing etc. must be accurate.
8) Serum dilution plate is disposable, do not use for second time;
the MAX volume of it is 300μL/well.
9. ELISA procedure
1) Take pre-coated microplate (Can unseal for several time use as
per sample quantity), add 100μL diluted serum to sample wells,
meanwhile set 1 well for Negative control, 2 wells for Positive
control separately. Add 100 μL Negative/Positive control to its
wells. Shake softly (do not spill), cover and incubate at 37℃ for
30 min.
2) Pour the liquid out of the wells, add 250μL diluted washing
solution to each well, pour out. Repeat 5 times, then pat to dry on
absorbent paper.
3) Add 100 μL Enzyme Conjugate to each well, cover andincubate at
37℃ for 30 min.
4) Repeat the step 2(washing). Remember pat to dry on absorbent
paper at last.
5) Add 100μL substrate solution to each well, mix properly,react
for 10 min at 37℃ in dark.
6) Add 50 μL stop solution in each well, and measure the result
within 10 min.
10. Results
Read the OD value with microplate-reader at 450nm (630nm as
reference).
For the test to be valid:
OD value of Negative control (N) < 0.15, meanwhile OD value of
Positive control (P)〉0.4.
Calculation method:
OD value of samples/ Average OD value of Positive control = S/P
value
Result judge:
S/P≥0.25, Positive.
S/P < 0.25, Negative;
Specifications: 96 or 96*2 wells/kit.
Expiry date:12 months.
Storage: Storing at 2-8℃, in the dark.
Q1: How long will it take for you to ship?
A1: Usually ships within 7 working days.
Q2: Do you support OEM/ODM?
A2: can be supported. We can customize according to your specific
needs and specific quantities.
Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 certification and ISO13485 certification, so
far all the production process, we have standard rules, we comply
with the relevant behavior and laws of the government.
Q4: Is after-sales service guaranteed?
A4: We provide professional online technical after-sales service.
If the product fails during the experiment, we can provide