VFD Double shield cables for steel factory In Viet Nam-ZR-BPYJVRP

Brand Name:ECHU
Certification:CE
Model Number:ZR-BPYJVRP
Minimum Order Quantity:100M
Delivery Time:7 to 10 days after receiving payment
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Site Member
Location: Shanghai Shanghai China
Address: No. 2600-88, Chuanzhou Road, Pudong District, Shanghai, 201315, China
Supplier`s last login times: within 9 hours
Product Details Company Profile
Product Details

Application:

The cable is used as power supply cables or electrical connection of inverter control system at AC rated voltage 0.6/1KV or less


Working Condition:

1.AC rated voltage Uo/U:0.6/1KV

2.Max working temperature PVC insulation is 70ºC,XLPE insulation is 90ºC

3.Min. enviroment temperature XLPE sheathed cable shall be not less than -70ºC ,PVC sheath cable shall be not less than -25ºC

4.Enviroment temperature shall be not less than 0ºC for cable in-stallation.

5.Min.bending radius for installation shall be 15 times outer diameter of cable.



Type and Name:

Typename
BPVVPPVC insulated and sheathed copper wire braided shield frequency converter power cable
BPVVP2PVC insulated and sheathed copper tape wrapped shielding frequency converter power cable
BPVVPP2

PVC insulated and sheathed copper wire braided copper tape wrapped shield
frequency converter power cable

BPVVP3

PVC insulated and sheathed aluminum polyester composite film wrapped and shielded
frequency converter power cable

BPYJVPXLPE insulated PVC sheathed copper wire braided shield frequency changer power cable
BPYJVP2XLPE insulated PVC sheathed copper tape wrapped shield frequency changer power cable
BPYJVPP2

XLPE insulated PVC sheathed copper wire braided copper tape wrapped shield
frequency changer power cable

BPYJVP3

XLPE insulated PVC sheathed aluminum polyester composite film wrapped and shielded
frequency changer power cable

Note: Prefix ZR is added to the flame retardant type cable's code


Technical Requirement:
1.Conductor DC resitance of cable should comply with the requirement of GB/T3956-2008
2.Insulation resistance constant(20ºC,min):PVC insulation:36.7MΩ/KM
3.Cable should withstand AC voltage testing of 50HZ,3.5KV/5min,no breakdown


Technical Requirement:
1.Conductor DC resitance of cable should comply with the requirement of GB/T3956-2008
2.Insulation resistance constant(20ºC,min):PVC insulation:36.7MΩ/KM
3.Cable should withstand AC voltage testing of 50HZ,3.5KV/5min,no breakdown



Technical Requirement:
1.Conductor DC resitance of cable should comply with the requirement of GB/T3956-2008
2.Insulation resistance constant(20ºC,min):PVC insulation:36.7MΩ/KM
3.Cable should withstand AC voltage testing of 50HZ,3.5KV/5min,no breakdown