Add to Cart
5Ton Industrial Air Cooled Water Chiller 18kW Scroll Type Glycol
Chiller China Factory Supply
How does a chiller system work?
The chiller operates with two circulations: one involves the circulation of process water, while the other entails the circulation of refrigerant gas. Heat absorbed from the process is transferred to the refrigerant circulation, and then expelled to either air or water.
Technical Parameters of Industry Air-cooled Chiller
Model | ACK-5 | |
nominal cooling capacity | kcal/h | 14964 |
kw | 17.4 | |
input power | kw | 5.53 |
power supply | 3PH 440V 60Hz | |
refrigerant | type | R407C |
type of control | capillary | |
compressor | type | hermeic scroll type |
power(kw) | 4.4 | |
condenser | type | finned copper tube + low noise outer rotor fan |
cooling air flow (m3/h) | 6000 | |
evaporator | type | shell and tube |
fan power(kw) | 2.8 | |
chilled fluid flow (m3/h) | 3 | |
volume (L) | 30 | |
inlet and outlet pipe diameter (inch) | 1 | |
pump | power (kw) | 0.75 |
lift(m) | 20 | |
safety protection | compressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection,flow switch protection, phase sequence or missing phase protection, exhaust overheating protection | |
weight | kg | 200 |
Dimension. | mm | 1300*650*1450 |
Note: The nominal cooling capacity is according to: Inlet chilled fluid temperature: 17℃,outlet chilled fluid temperature: 12℃.
Air Cooled Water Chiller:
The air cooled chiller водяной охладитель, also known as an
air-cooled box-type industrial chiller unit, utilizes a air-cooled
heat dissipation design. It draws surrounding air into the
equipment using built-in fans and dissipates heat through a
condenser, thereby reducing the system temperature. It does not
require an additional water cooling system and is relatively easy
to install and maintain.
Air cooled chiller is suitable for places with limited space or
where sufficient cooling water cannot be provided. However, the
cooling efficiency is affected by ambient temperature and humidity,
so it is typically used in applications with lower heat loads. Each
model is equipped with a range of safety features, including motor
overload protection, phase loss and phase reversal alarms,
anti-freeze thermostats, pressure gauges, and more. These chiller
units demonstrate excellent performance and have a longer lifespan.
Throughout the entire operating cycle, a series of steps based on
the fundamental principles of heat exchange are followed. They are
particularly suitable for industries that require precise control
and regulation of chilled water temperature, allowing for precise
control within the range of 3°C to 50°C, making them an important
player in the modern industrial sector.
Working Principle of Water Chiller:
When the air cooled chiller starts, the refrigerant absorbs the
heat from the cooled object in the evaporator and vaporizes. The
compressor continuously extracts the generated gas from the
evaporator and compresses it into high-temperature, high-pressure
vapor. The refrigerant vapor is then sent to the condenser, where
it undergoes heat exchange with the air. After releasing heat, it
condenses into a liquid. The liquid refrigerant, after being
depressurized by the expansion valve, enters the evaporator where
it vaporizes again, absorbing heat from the cooled object. This
heat exchange process is repeated until the industrial water is
cooled to the desired temperature.
Chiller Application:
Chillers are widely used in various industrial productions such as
plastics, electronics manufacturing, electroplating, chemical
engineering, ultrasonic cooling, and printing. They are employed in
the cooling of molds for plastic processing machinery,
significantly improving the surface smoothness of plastic products,
reducing surface flaws and internal stress, preventing shrinkage
and deformation, facilitating mold release, accelerating product
shaping, and thus greatly enhancing the production efficiency and
product quality of plastic molding machines.
Installation&Maintenance of SZAGZ Chiller
Maintenance: Air-cooled chillers eliminate the need for cooling towers and no need water treatment, chiller condenser-tube cleaning, tower mechanical maintenance.
Installation: Most of the air-cooled chillers are packed systems which are including the air-cooled finned condenser, evaporator compressor and evaporator.Some of them are built-in water storage tank and pump,they are designed and configured at the factory for optimal performance and reliability, which reduces design and simplifies installation.
About SZAGZ Chiller service?
①24 hours Online support;
②Video technical support;
③Overseas third-party support available and etc.