Introduction
What is CET&RET
Capactive Elecric Transfer(CET) is a method that allows the RF
electrical current to be transferred “by capacity”(principle of the
electrical capacitor) to the patient’s body via a moveable external
apllication electode.This is covered with an insulating film which
acts as dielectric and the body acts as a second plate of the
capacitor.A return plate closes the circuit.The electric
circulation through the resistive medium formed by the live tissues
increases its temperature.
The Resistive Electrical Transfer(RET) ,introdued in 1994,is different from the CET in the basically THE APPLICATION ELECTRODE IS NOT INSULATED,allowing the current to be transferred directly to the patient with less dispersion,thus obtaining an increase in temperature at a greater depth.
HYPERTHERMIA
.The therapeutic effects of Hyperthermia on the human body have
been well-known since the 19th Century.mainly being indicated for
inflammatory proccess,ususlly accompanied by pain.Methods used made
it very difficult to obtain deep.controlled and harmless thermal
increase and some required “invasive” techniques.
What is Therma-S
Therma-S is intended for therapeutic diathermy to produce deep
heating without excessive temperature elevationof the skin surface
and subcutaneous tissue.Therma B Plus is applied to any part of the
human body without pain,musclar contraction or disagreeable
sensation of any kind.
The principle of RF Diathermy
.The treament sithe is placed between the plates of a capactor and
becomes the dielectric.
.The RF energy is diffused through the part of the body locate
between the plate electrodes.
.The oscillating fields produce distortion of molecules,rotation of
dipoles and vibration of ions.
.The movement of the molecules and ions generates heat within the
tissues.
.These action have been shown to have positive clinical effect on
enhancing blood flow.
Therma-s Hyperthermia Applications
The Therma-s method is currently being appliled in most medical
specialities, particularly in:
Traumatology and Rehabilitation.
Rheumatology
Sports Medicine
Pain Clinics
Thechnical Specification
General
Power input:10v-224v 50/60HZ
Maximum Power Consumption:200w
Classification(EN60601-1):Class 1. Type BF
Main Fuses:2*T2A(5*20mm)
Size(height*width*depth):1000*370*450mm
Weight:30kg
Out Parameter
Carrier Frequency:0.3MHz and 0.5MHz
Maximum Intensity:80Ma RMS
Out Modes:Round Electodes/Rectangle Type
Treatment Timer:0-60minutes
Safety Device:Zero Start,Safety Switch
Accessories
1 Neutral Plate
2 Treatment handle
3 Safety Switch
4 Electrodes for RET
5 Capacitive Electrodes for CET
6 Treatment handle