Home /

Shockproof Practical Fire Retardant ACP , Heatproof Aluminium Cladding Fire Rating

Shockproof Practical Fire Retardant ACP , Heatproof Aluminium Cladding Fire Rating

Brand Name:MEGABOND CROWNBOND
Certification:sgs ISO
Model Number:1220*2440MM 4MM
Minimum Order Quantity:360-1200meter square
Delivery Time:15-20days
Payment Terms:L/C, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou China
Address: No 8 maxing street make vallage, Dongchong Town, Nansha district Guangzhou City. PRC. Potsal code: 511475
Supplier`s last login times: within 12 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Fire Retardant ACP Sheets 1220 X 2440 X 4mm For Wall Cladding

The fire rated ACP can resist fire for up to 2 hours. The main difference between fire-rated ACP and normal ACP sheets is that both are ACP but with different core materials. The mineral core is made up of about 70% inorganic materials such as Calcium Hydroxide and Magnesium Hydroxide and 30% polymer. The core of the normal ACP is LDPE/HDPE minerals whereas the fire rated ACP is made of the specially formulated fire resistant mineral core.


MEGABOND is a professional and renowned aluminium composite panel manufacturer in India offering superior quality panels. It is a leader in the ACP industry. The ever-growing confidence of our clients is reflected in the increased production and offtake of our products.


1. Material composition

MEGABOND™ is an Aluminum Composite Material (ACM) for the construction industry worldwide. It is not only a reasonable alternative to solid aluminum sheet, but also an individual material characterized by its own unique features. Its lightweight, high rigidity, excellent flatness and long lasting coating qualities are just what the construction industry has been looking for.


MEGABOND™ /fr is an aluminum composite material (ACM) with a fire-retardant core suitable for exterior and interior cladding, soffit linings and roof covering in new buildings and retrofit applications.


MEGABOND™A2 is an aluminum composite material (ACM) with a high fire-retardant core suitable for exterior and interior cladding, soffit linings and roof covering in new buildings and retrofit applications.


MEGABOND™, MEGABOND™/fr, MEGABOND™ A2 are often simply referred to as “MEGABONDs” or “MEGABOND products” in this brochure, if the context is applicable to both products. We will use the respective MEGABOND, MEGABOND/fr, MEGABOND A2 if we need to mention each of them separately.


The core of MEGABOND is black and those of MEGABOND/fr, MEGABOND A2 are gray or white containing a mineral. Thus, we can discern each product by appearance. The total thickness is 3, 4 and 5mm.

Fig. 1-1 Composition of MEGABONDs

Topside of MEGABONDs is finished with a paint called LITONG™-based fluoropolymer paints as standard and backside is finished with a thin polyester coating (wash coating) or a service coating. The topside is covered with a protective Film.


Total thickness: 3, 4 and 5 mm ( MEGABOND, MEGABOND/fr and MEGABOND A2),


2.Production process

The production process of MEGABONDs consists of two production lines: a coil coating line and a laminating line. In the coil coating line, LITONG-based fluoropolymer paints are applied to continuous aluminum coils. In the laminating line, the low-density polyethylene or the mineral-filled core is laminated between two coated coils, resulting in the finished composite material.


After laminating, the finished products are packed in wooden cases and shipped to customers’ workshops. Thus, MEGABOND products are shipped as flat panels and processed in local workshops according to project drawings.


3.Features

MEGABONDs have a number of unique features:

Flatness: The continuous laminating process results in excellent flatness of the panel.

Color uniformity: The coil coating process ensures complete color consistency.

Rigidity: As one of the attributes of ACM, MEGABONDs are light and strong sheet materials, reducing the weight by 9% (MEGABONDA2) or 15% (MEGABOND/fr) compared to solid aluminum sheets with equivalent rigidity.

Workability: MEGABONDs are easy to cut, bend, groove and shape with regular aluminum working and woodworking machines and tools.

Fire safety: With the fire-retardant core, MEGABOND A2 and MEGABOND/fr meet fire code requirements in several countries including Europe, North America, Middle East and Japan without any restrictions.

(1)Flatness

(2)MEGABONDs are very flat. Generally speaking, ensuring the flatness of sheet materials is not easily realized. Solid aluminum sheet, for example, has a slight distortion stemming from its rolling process: buckles, edge waves and overall warping are common.

MEGABONDs are extremely flat due to the thinness of the aluminum sheets (0.5mm) and our lamination process in which most of such distortions are eliminated.


(1) Rigidity

MEGABONDs are highly rigid compared to solid aluminum metal sheets. As shown in Fig. 1-4, two sheets of aluminum skin behave like a small H-section when pressure is applied on the panel. Consisting of 2 sheets of 0.5mm thick aluminum, MEGABONDs 4mm thick deliver the rigidity equivalent to an aluminum sheet of 3.3mm thick.


Table 1-1 Comparison of rigidity between MEGABONDs and solid aluminum sheet

MaterialMEGABONDSolid aluminum sheetWeight ratio Solid aluminum =100%
Thickness mmWeight kg/m2

Equivalent

thickness,mm

Weight

kg/m2

MEGABOND A236.42.77.388%
48.13.38.991%
511.74.512.296%
MEGABOND FR36.02.77.382%
47.63.38.985%
510.94.512.289%

Note 1: How to read the above table: MEGABOND /fr 4mm is equivalent to aluminum sheet 3.3mm in rigidity. Hence, the weight percent of MEGABOND to solid aluminum is 85%.

Note 2: MEGABOND A2 is heavier in weight than MEGABOND /fr due to high mineral content in the core.

(3) Workability

The workability of MEGABONDs is one of its outstanding features. It can be cut with circular saws. It can be folded after grooving with a groove cutter or a router. It can be bent with a 3-roll bender and press

brake. For joining, we can choose the most suitable method from several alternatives. For details, refer to Section 3 “Fabrication and installation.

Fig. 1-5 Tools and machines used for processing MEGABONDs


(4) Fire safety

MEGABON A2 MEGABOND/fr, MEGABOND A2 fire-safe materials which pass mandatory requirements for exterior and interior in several countries. Though the core material does contain a small amount of combustible polyethylene, the main ingredient of the mineral does not permit the proliferation of flame and restricts the development of smoke detrimental to evacuation activities.

MEGABONDs are composed of two aluminum skins which retard the spread of fire. Extensive fire tests have been performed on MEGABOND/fr, MEGABOND A2 in accordance with requirements in various countries. Refer to Section 2 Characteristics” for details.

Fig. 1-6 Examples of fire tests applied to MEGABOND/fr


MEGABOND FR B1 DATA SHEET

CLASS B - (s1, d0)

PHYSICAL PROPERTIES
TEST STANDARDREQUIREMENTRESULT
4MM5MM
Panel Thickness-----------------(±) 0.2 mm4.02MM5.02MM
Weight of the Panel-----------------

≥ 7kg/m2 - 4mm

≥ 8kg/m2 - 5mm

7.2KG/M28.1KG/M2
Standard Width-----------------(±) 2 mm1000, 1250, 1500
Length-----------------(±) 2 mmup to 6000 mm
Skin Thickness-----------------(±) 0.03 mm0.5 mm
Alloy / TemperASTM B2093003 H143003 H14
FIRE PERFORMANCE
TEST STANDARDREQUIREMENTRESULT
4MM5MM
Reaction to FireEN 13501-1Class B, s1, d0TBW 0300136.2

Surface Burning

Characteristics

ASTM E84

(FSI) 25-0

(SDI) 450-0

FSI 15, SDI 30

Class A

FSI 15, SDI 40

Class A

Self Ignition

Temperature (ACP)

ASTM D 1929Not less than 343˚C

SIT (783˚F) 417˚C,

FIT (779˚F) 415˚C

SIT (849˚F) 454˚C,

FIT (846˚F) 452˚C

Self Ignition

Temperature (CORE)

SIT (777˚F) 414˚C,

FIT (763˚F) 406˚C

SIT (777˚F) 414˚C,

FIT (763˚F) 406˚C

Exterior Non-Load Bearing

Wall Cladding Assemblies

As per standard

As per standard


TBW0300169.2TBW0300118.2

COIL SPECIFICATION
TEST STANDARDREQUIREMENTRESULT
4mm5mm
Tensile StrengthASTM E8172 - 221 N/mm2205 - 218 N/mm2
Yield StrenthASTM E8Min. 145 N/mm2206 N/mm2
ElongationASTM E8Min. 1.0%3.40%
MECHANICAL PROPERTIES
TEST STANDARDREQUIREMENTRESULT
4mm5mm
Peel off strength @ 180°ASTM D 1781≥ 10 kg/25mm17.3 kg/25mm17.3 kg/25mm
Shear StrengthASTM C 273≥ 3.2MPa3.49 Mpa4.35 Mpa
Tensile strengthASTM D638Measure Value43.9 Mpa
Yield StrengthASTM D638Measure Value34.3 Mpa
ElongationASTM D638Measure Value3.82%
Modulus of ElasticityASTM C393Measure Value19,600 Mpa
Flexural StrengthASTM D790-17Measure Value110.7 Mpa
THERMAL PROPERTIES
TEST STANDARDREQUIREMENTresult
4mm5mm
Deflection TemperatureASTM D 648≥ 100˚C189.8˚C215.1˚C
Thermal ExpansionEN 1999 1-1Measure Value94.8 µm/m˚C
Thermal ConductivityASTM C 518Measure Value0.13 W/mK0.10 W/mK
COATING PROPERTIES AND PERFORMANCE
TEST STANDARDREQUIREMENTresult
4mm5mm
Type / FinishPVDF / FEVEPVDF / FEVE
Coating ThicknessASTM D 1400≥ 25μm≥ 25μm
Weathering ResistanceASTM C 481

A. Shear Strength

B. Film Adhesion

C. Impact Resistance

A. 3.75 Mpa (after exposure)

B.1.Dry Adhesion - No removal of film

B.2. Wet Adhesion - No removal of film

B.3. Boiling Water - No removal of film

C. Impact Resistance - No removal of film

Corrosion ResistanceAAMA 2605

A. Humidity Resistance

B. Salt Spray Resistance

A. No formation of blisters

B.1 Scribed - rating of 9

B.2. Unscribed - rating of 10

Abrasion ResistanceASTM D 968Min 40 L/mil43.9 L/mil
Pencil HardnessASTM D 3363Min HB> 3H
Film AdhesionASTM D3359No removal of filmNo removal of film nor blistering

Impact Resistance Test

50 kg-cm

ASTM D 2794No removal of filmNo removal of film

MEGABOND TECHNICAL DATA SHEET

MEGABOND TYPEMEGABOND B1MEGABONDA2
Panel thicknessstandardunit3mm4mm5mm3mm4mm5mm
Alu thickness0.5mm0.5mm
core70% Mineral Filling93% Mineral Filling
weightKg/m2677.66.57.58.1
Section Modulus zDIN 53293cm 3 /m1.251.752.751.251.752.75
Rigidity EIDIN 53293kNcm2/m125024005900125024005900
Modulus of Elasticity EEN 1999 1.1

Mpa


7000
AlloyEN 573.3EN AW 1100/3003
TemperH12/H14
Tensile StrengthEN 485.2MPaRm => 130
0.2% Proof StressEN 485.2MPaRp0.2 => 90
ElongationEN 485.2%A50 = > 5
Linear Thermal ExpansionEN 1999 1.12.4mm/m at 1000 C temperature difference
FinishCoil Coated Fluoropolymer (PVDF or FEVE)
GlossEN 13523.2Finish Dependant - Standard = 30 - 40%
Pencil HardnessEN 13523.4HB - F
Acoustic Properties
Sound Absorption factor asISO 3540.05
Sound Transmission Loss RwEN ISO 140.3dB272727272727
Loss Factor dEN ISO 67210.0040.005
Thermal Properties
Thermal Resistance RDIN 52612m2K/W0.0060.0090.01510.0020.0030.005
Thermal Conductivity lDIN 52612W/mK

0.33/mm thickness of core

1.00/mm thickness of core

Heat Transition Coefficient UDIN 4108W/m2K5.685.585.345.835.805.71
Temperature Resistance0 C'-50 up to +80
Fire Behaviour
Australian Fire Classification

ABCB

CodeMark

Certification

Cert. No. GM CM 30070

Type A and B Constructions

Mechanical fixing


Type C Constructions

Mechanical and tape fixing

AS ISO 9705Group 1 MaterialGroup 1 Material
EN13501.1B-s1-d0A2-s1-d0
NFPA 285PASS
BS-8414Test data available

Sheet Sizes

Widths: 1250mm & 1575mm held in stock. 1000mm, 1500mm and special widths 1750mm & 2050mm available as project order.Note: 1750mm width requires minimum 2000m2 order. 2050mm width requires 6000m2 order and cannot be mixed with standard width colours.

Lengths: 2500mm, 3200mm & 4000mm held in stock. Other lengths up to 10,000mm available as project order.

Surface Finishes

Standard Colour Range; Spectra Colour; Sparkling Effect ;Anodized Look ; Urban Design; NaturAL;NaturAL Finesse ;Design Decor;Terra


High quality Fluoropolymer finishes (PVDF and/or FEVE) with optimum UV & weathering properties are used exclusively.

Non standard custom colours are available subject to minimum quantity requirements.

Solar Reflective Indices (SRI) and Light Reflective Values (LRV) for most of the above finishes are available upon request.

Environment, Health & Safety

During the life cycle of MEGABOND no substances containing CFC, VOC’s are released. The core material does not contain any Nitrogen, Chlorine or Sulphur.Guangzhou Xinghe decorative material co,.ltd were one of the first companies to develop its own environmental management systems which is regularly audited by independant auditorsand is certified to EN ISO 14001 All MEGABOND finishes are RoHS compliant and contain no Lead, Cadmium, Mercury or Chromium.


China Shockproof Practical Fire Retardant ACP , Heatproof Aluminium Cladding Fire Rating supplier

Shockproof Practical Fire Retardant ACP , Heatproof Aluminium Cladding Fire Rating

Inquiry Cart 0