*Trimmed Offset Voltage:
TLC277 . . . 500 µV Max at 25°C, VDD = 5 V
*Input Offset Voltage Drift ...Typically
0.1 µV/Month, Including the First 30 Days
*Wide Range of Supply Voltages Over
Specified Temperature Range:
0°C to 70°C . . . 3 V to 16 V
–40°C to 85°C . . . 4 V to 16 V
–55°C to 125°C . . . 4 V to 16 V
*Single-Supply Operation
*Common-Mode Input Voltage Range
Extends Below the Negative Rail (C-Suffix, I-Suffix types)
*Low Noise ...Typically 25 nV/√Hz at f = 1 kHz
*Output Voltage Range Includes Negative Rail
*High Input impedance . . . 1012 Ω Typ
*ESD-Protection Circuitry
*Small-Outline Package Option Also Available in Tape and Reel
*Designed-In Latch-Up Immunity
description
The TLC272 and TLC277 precision dual operational amplifiers combine
a wide range of input offset voltage grades with low offset voltage
drift, high input impedance, low noise, and speeds approaching
those of general-purpose BiFET devices.
These devices use Texas Instruments silicongate LinCMOSTM technology, which provides offset voltage stability far exceeding
the stability available with conventional metal-gate processes.
The extremely high input impedance, low bias currents, and high
slew rates make these costeffective devices ideal for applications
previously reserved for BiFET and NFET products. Four offset
voltage grades are available (C-suffix and I-suffix types), ranging
from the low-cost TLC272 (10 mV) to the high-precision TLC277 (500
µV). These advantages, in combination with good common-mode
rejection and supply voltage rejection, make these devices a good
choice for new state-of-the-art designs as well as for upgrading
existing designs.
absolute maximum ratings over operating free-air temperature range
(unless otherwise noted)†
Supply voltage, VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . .. . . . . .
. . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . .18V
Differential input voltage, VID (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . ±VDD
Input voltage range, VI (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to VDD
Input current, II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . ±5 mA
output current, IO (each output) . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
±30 mA
Total current into VDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. 45 mA
Total current out of GND . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . 45 mA
Duration of short-circuit current at (or below) 25°C (see Note 3) .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.unlimited
Continuous total dissipation . . . . . . . . . . . . . .. . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .See Dissipation
Rating Table Operating free-air temperature, TA: C suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . 0 °C to 70°C
I suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . –40°C to 85°C
M suffix . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . –55°C to 125°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. –65°C to 150°C
Case temperature for 60 seconds: FK package . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
260°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D, P,
or PW package . . . . . . . .. . . . . . . 260°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG
package . . . . . . . . . . . . . . . . . . . . . . 300°C
† Stresses beyond those listed under “absolute maximum ratings” may
cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other
conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated
conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages, are
with respect to network ground.
2. Differential voltages are at IN+ with respect to IN–.
3. The output may be shorted to either supply. Temperature and/or
supply voltages must be limited to
ensure that the maximum dissipation rating is not exceeded (see
application section).
recommended operating conditions
C SUFFIX | I SUFFIX | M SUFFIX | UNIT | ||
MIN MAX | MIN MAX | MIN MAX | |||
Supply voltage, VDD | 3 16 | 4 16 | 4 16 | V | |
Common-mode input | VDD = 5 V | –0.2 3.5 | –0.2 3.5 | 0 3.5 | V |
VDD = 10 V | –0.2 8.5 | –0.2 8.5 | 0 8.5 | ||
Operating free-air temperature, TA | 0 70 | –40 85 | –55 125 | °C |