1.Name:VP2 Variable Displacement Vane Pumps
2.Intriduction:
VP Series variable Displacement vane pumps are the products with
limiting pressure, equipped with both pressure and flow adjustment
facilities. The outlet flow of the pump can regulate itself
automatically according to the load, by which the outlet power and
the working speed are in tune with the load. The pump is
characterized by high efficiency, saving energy, safety and
creditability and so on,and can be used in the hydraulic system for
volumetric regulation, for instance, cutting machine tools,
pressure and leather machinery, hydraulic station, and so on.
3.Specification:
Model | Outlet flow L/min at 0.35MPa and 1800 r/min | Operating pressure range MPa | Range of speed r/min | Direction of rotation (Viewed from shaft end) | Weight kg |
VP2-30-20 | 30 | 1.0—2.0 | 800-1800 | Clockwise | 9 |
VP2-30-35 | 1.5—3.5 |
VP2-30-55 | 3.0—5.5 |
VP2-30-70 | 5.0—7.0 |
VP2-40-20 | 40 | 1.0—2.0 |
VP2-40-35 | 1.5—3.5 |
VP2-40-55 | 3.0—5.5 |
VP2-40-70 | 5.0—7.0 |
4.Model Code:
5.Installation and Use:
(1)Clockwise rotation viewed from shaft end is standard.
(2)The pump shaft must be horizontally installed. For proper
alignment of pump and electric motor shaft, the eccentricity
between them must be kept within 0.05mm and the eccentric
angle error between them must be kept within 1°. The shaft ends
avoid increasing radial and axial loads. In addition,please use
sufficient rigid material as the mounting bracket.
(3)Fix pipes, especially inlet pipes,in accordance with the size of
port ; Inlet pipes must be strictly sealed with no leakage.
System should be equipped with cooling device (without cooling
unit, should increase fuel tank volume)
The fuel tank shall be equipped with a diaphragm to separate the
bubbles and dirt from the oil;
The oil return nozzle should be lower the fluid surface, the
minimum depth of 50 mm, even in a low, too, when the permissible
level of to avoid the formation of bubbles . Inlet port
pressure should be -0.03 to +0.03MPa;In case where the pump is
installed on the tank or at the position higher than the tank top
cover, the height of the suction port of the pump should
be less than 500mm.
(4)Drain connection must be piped directly to tank and below the
oil level with a back pressure not exceed 0.03MPa.
(5)The setting value of P-Q at the factory:
·Flow setting:The max. flow as catalogue shown.
·Pressure setting:The min. operating pressure range.
(6)Flow and pressure adjustment:
For adjusting them, first loosen the tightly locked nut, and then
spin screws,After adjustment, tighten the lock nut.
·The flow will be reduced when the flow adjusting screw is turned
clockwise and increased when anti-clockwise.
·The pressure will be increased when the pressure adjusting screw
is turned clockwise and reduced when anti-clockwise.
(7)Thrust bolt
The thrust bolts are set when the pump is assembled,Please do not
adjust.
(8)Hydraulic oil:
·Use the hydraulic oil of 30 ~ 50cSt (ISO VG32) at 40 ℃ .
·The hydraulic oil temperature range of 15 ~ 60 ℃ . Initial oil
temperature below 15 ℃ , please use the low voltage operation to
oil temperature 15 ℃ .
(9)Oil should be kept clean, pipes and tanks must be thoroughly
cleaned.Precise filters should be assembled with the advised
precision of 25μm in the system, the cleanness level of oil
should be within NSA10; Fix the sufficient-volume filter (the rated
flow rate should be greater than twice the pump flow )at the inlet
of the pump 50mm above the bottom of the tank, with the suggested
precision of 100μm(150 mesh).
(10)To ensure adequate lubrication of the pump sliding surface,
please fill the pump body before running.
(11)First use :Start up the pump under No-Load condition and repeat
to start and stop the motor several times to extract the air from
inside of the pump and piping. Then keep a 10 minutes continuous
running for a better de-airing. For exhaust pipes, install an
exhaust valve.
6.Install Connection Dimensions:
Single Pump
◆ VP2(1-Str. Key shaft)
◆ VP2(2-Spline shaft)
According to the US ANSI B92.1 specifications Class of accuracy :
Class 5
Module | D.P.16/32 |
Pressure Angle | 30° |
Number of Teeth | 9 |
Pitch Diameter | Φ14.2875 |
Maximum Diameter | Φ15.875 0 -0.05 |
Minimum Diameter | Φ11.811(MAX) |
Characteristic Curves