Product Details
KEYSIGHT N9032B PXA SIGNAL ANALYSER, 2 HZ TO 55 GHZ,MAXIMUM
ANALYSIS BANDWIDTH 2GHZ
Description of Keysight Agilent N9032B
Specifications describe the performance of parameters covered by
the product warranty and apply to temperature ranges 0 to 55 °C,
unless otherwise noted. 95th percentile values indicate the breadth
of the population (approx. 2 σ) of performance tolerances expected
to be met in 95 percent of the cases with a 95 percent confidence,
for any ambient temperature in the range of 20 to 30 °C. In
addition to the statistical observations of a sample of
instruments, these values include the effects of the uncertainties
of external calibration references. These values are not warranted.
These values are updated occasionally if a significant change in
the statistically observed behavior of production instruments is
observed. Typical values (typ) describe additional product
performance information that is not covered by the product
warranty. It is performance beyond specifications that 80 percent
of the units exhibit with a 95 percent confidence level over the
temperature range 20 to 30 °C. Typical performance does not include
measurement uncertainty. Nominal values (nom) indicate expected
performance or describe product performance that is useful in the
application of the product but are not covered by the product
warranty. The analyzer will meet its specifications when: • It is
within its calibration cycle. • Under auto couple control, except
that Auto Sweep Time Rules = Accy • For signal frequencies < 10
MHz, DC coupling applied. • Analyzer is used in environment that
falls within allowed operating range; and has been in that
environment at least 2 hours before being turned on. • Analyzer has
been turned on at least 30 minutes with AutoAlign set to Normal;
or, if Auto Align is set to Off or Partial, alignments must have
been run recently enough to prevent an Alert message. Note that
factory default is with the AutoAlign set to Light, which (compared
to Normal) allows wider temperature changes before causing
Alignments to run automatically. The benefit is that Alignments
interrupt less frequently. The user can change AutoAlign to Normal
if desired, and this setting will persist after power cycle or
PRESET. If the Alert condition is changed from “Time and
Temperature” to one of the disabled duration choices, the analyzer
may fail to meet specifications without informing the user. In
practice, the impact of such choices is primarily on Absolute
Amplitude Accuracy. If temperature changes are small, the impact of
Light vs Normal is negligible. Also, the user may invoke Align All
at any time, to get the best possible accuracy. • The term “mixer
level” is used as a condition for many specifications in this
document. This term is a conceptual quantity that is defined as
follows: Mixer Level (dBm) = RF Input Power Level (dBm) -
(Mechanical Attenuation) (dB) - (Electronic Attenuation) (dB). •
The term “attenuation” is used for many specifications in this
document; this refers to the Mechanical Attenuator, unless
otherwise stated.
List of Options for N9032B
|
Type | 1 |
Place of Origin | Malaysia |
Warranty | 1 Year |
Customized support | OEM |
Brand Name | Keysight |
Model Number | N9032B |
Frequency | 2 Hz to 55 GHz |
DANL @1 GHz | -174 dBm |
Maximum Analysis Bandwidth | 2 GHz |
Maximum Real-Time Bandwidth | Up to 2 GHz |
Phase Noise @1 GHz
|
FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual
delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .
Company Profile
Meigaolan is a test and measurement solutions and production
suppliers, founded in 2003 and located in Shenzhen,China.
Our highly skilled Sale Representatives can assist you with all of
your
new and refurbished test equipment needs, providing EMC test
solutions
and building your Anechoic chamber.
We own 7 repair labs in China

Warehouses all over China


Business partners