KEY FACTS OF Rohde & Schwarz ZVH4 Portable Cable Analyzer
► Frequency range from 100 kHz to 3.6 GHz or 8 GHz
► 100 dB (typ.) dynamic range for filter and antenna isolation measurements
► Factory calibration over entire frequency range
► Built-in DC voltage supply (bias) for active components such as amplifiers
► Power meter option
► Saving of measurement results on SD memory card or USB memory stick
► Easy operation with user-configurable test sequences (wizard)
► Easy-to-replace Lithium-ion battery for up to 4.5 h of operation
► Rugged, splash-proof housing for rough work in the field
► Easy handling due to low weight (3 kg with battery) and easy-to-reach function keys
BENEFITS AND KEY FEATURES OF Rohde & Schwarz ZVH4 Portable Cable Analyzer
Installation of antenna systems
► Distance-to-fault measurements (DTF)
► One-port cable loss measurements
► Reflection measurement
► Transmission measurements
► Built-in DC voltage supply
► Position finding using GPS receiver
► Factory calibration of the R&S®ZVH


Maintenance of antenna systems

► Two-port vector network analysis
► Vector voltmeter
► Terminating and directional power measurements
► Pulse analysis with wideband power sensors
► Internal channel power meter
► Spectrum analysis measurements
► Spectrogram measurements


Easy operation

► Test report in just a few steps using the
R&S®ZVH wizard
► Channel tables for frequency setting
► Optimal reading of measurement results in any situation
► Operation in different languages
► Easy-to-access, well-protected connectors


Documentation and remote control

► R&S®InstrumentView software for documenting
measurement results
► Remote control via LAN or USB


Specifications of Rohde & Schwarz ZVH4 Portable Cable Analyzer

Frequency

Frequency rangeR&S®ZVH4100kHzto3.6GHz
R&S®ZVH8100kHzto8GHz
Frequency resolution1Hz
Reference frequency, Internal
Total reference accuracy± (time since last adjustment × aging rate)
+ temperature drift + calibration accuracy
Aging per year±1 × 10-6
Temperature drift0 °C to + 50 °C ¹±1 × 10-6
Achievable initial calibration accuracy±5 × 10-7
Reference frequency, with R&S®HA-Z240 GPS receiver option
Frequency accuracyGPS on, ≥ 1 min after satellite lock±2.5 × 10–8
up to 30 min after losing satellite lock±5 × 10–8
Reference frequency, with R&S®FSH-Z114 precision frequency reference option
Aging per year3.6 × 10–9
Temperature drift0 °C to + 50 °C4 × 10–10
Achievable initial calibration accuracy1 × 10–9
Total reference uncertaintyR&S®FSH-Z114 connected
≥ 30 s after oscillator lock(time since last adjustment × aging rate) + temperature drift + 3 × calibration accuracy (nominal)
≥ 2 min after oscillator lock(time since last adjustment × aging rate) + temperature drift + calibration accuracy
Frequency readout
Marker resolution0.1Hz
Accuracy± (marker frequency × reference accuracy) + 10% × measurement bandwidth + ½((fstop–fstart) / (data points – 1) + 1 Hz)

Measurement

Individual measurementsreflection (S11, S22)
with R&S®ZVH-K39 optiontransmission (S21,S12)
one-port cable loss
distance-to-fault
Measurement Wizard
Guides the user through a sequence of individual measurements, uses the R&S®InstrumentView PC software to configure the measurement sequence including hints displayed on the screen;
R&S®InstrumentView is also used to combine the measurement results into user-configurable reports.

Measurement set up
Port output powercontrolled via tracking generator attenuation0 dBm to – 40 dBm (nom.), in 1dB steps
Receive path RF attenuation0 dB to 30 dB in 5 dB steps
Data pointsselectable101, 201, 401, 601, 631, 801, 1001, 1201
Measurement bandwidthrange100 Hz to 100 kHz in 1/3 sequence
Trace modesclear/write average, interference
suppression
DC bias
DC sourceselectableinternal or external
Output portselectableport 1 or 2
Output voltagemode: internal+12 V to + 32 V in 1 V steps
Maximum output powermode: internal
operatedwithbattery4 W
operatedwithACmains10 W
Maximumcontinuousoutputcurrentmode: internal500 mA
Trigger
Trigger sourcefree run, external rise, external fall
External trigger levelTTL level

Reflectionmeasurement S11, S22
Result formatsmagnitude,VSWR
Magnitude
Range1/2/5/10/20/50/100/120/150 dB, linear 100%
Resolution0.01dB
VSWR
Rangeselectable1 to 1.5, 2, 6, 11, 21 or 71
Corrected directivity100 kHz ≤ f ≤ 3 GHz> 43dB (nom.)
3 GHz < f ≤ 6 GHz> 37dB (nom.)
6 GHz < f ≤ 8 GHz> 31dB (nom.)
Corrected test port match100 kHz ≤ f ≤ 3 GHz> 40dB (nom.)
3 GHz < f ≤ 6 GHz> 37dB (nom.)
6 GHz < f ≤ 8 GHz> 30dB (nom.)
Measurement uncertaintysee figure “Uncertainty of reflection measurement” on page7

Transmission measurement S21, S12 (withR&S®ZVH-K39 option)
Result formatmagnitude
Measurement range–120dBto+80dB
Display rangeselectable1/2/5/10/20/50/100/120/150dB,
linear100%
Resolution0.01dB
Dynamic rangeRF attenuation = 5dB, tracking generator level = –10 dBm, RBW = 1 kHz
100 kHz ≤ f < 300 kHz> 50 dB (nom.)
300 kHz ≤ f < 2.5 GHz> 80 dB,100 dB (typ.)
2.5 GHz ≤ f < 6 GHz> 70 dB, 90 dB (typ.)
6 GHz ≤ f < 8 GHz> 50 dB (nom.)
Test port matchas specified for test port input/output
Measurement uncertaintycalibration method = full two port high accuracysee figure “Transmission magnitude uncertainty” on page 7

One-port cable loss measurement
Result formatmagnitude
Rangeselectable1/2/5/10/20/50/100/120/150 dB
Resolution0.01dB

Distance-to-fault analysis
Result formatsreturn loss, VSWR (average and maximum indication)
Return loss
Range1/2/5/10/20/50/100/120/150dB, linear100%
Resolution0.01dB
VSWR
Rangeselectable1to1.5,2,6,11,21or71
Fault resolution in meters(1.5 × 108 × velocity factor/span)
Maximum cable lengthdepending on cable loss1500 m (nom.)

Immunity to interference
Maximum permissible spurious signalmeasurement = reflection (S11)/one-port cable loss/distance-to-fault analysis
RF attenuation = 5 dB+10 dBm (nom.)
RF attenuation = 30 dB+17 dBm (nom.)


FAQ:


1. Can you ship the order to Canada or Australia?

Yes, we can. We send orders worldwide.


2. What delivery method and delivery time do you use?

We can ship by EMS, DHL, FedEx, UPS, and TNT with tracking numbers. The usual delivery time is 4-7 workdays.


3. What is your payment term?

100% T/T payment before shipment.


4. How can I ask any other question?

You can contact us online or leave us messages below.


China Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4 supplier

Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Inquiry Cart 0