Home /Used Measuring & Analysing Instruments /

Agilent Keysight 34470A Digital Multimeter 7.5 Digit Truevolt DMM Benchtop / Rackmount

Agilent Keysight 34470A Digital Multimeter 7.5 Digit Truevolt DMM Benchtop / Rackmount

Brand Name:Keysight/Agilent
Model Number:34470A
Minimum Order Quantity:1 set
Payment Terms:T/T
Place of Origin:Malaysia
Price:Negotiation
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China
Supplier`s last login times: within 28 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Keysight Agilent 34470A Digital Multimeter 7 ½ Digit Basic Truevolt

Description of Keysight Agilent 34470A Digital Multimeter

The Keysight 34470A 7½ digit, Performance Truevolt Digital Multimeters offer higher levels of accuracy, speed and resolution.



1. Specifications are for 90-minute warm-up, integration setting of 10 or 100 NPLC, auto-zero on, AC slow filter. ACAL run within the last 2 days.

2. 20% over range on all ranges, except 1000 DCV, 750 ACV, 10 DCA, 3 DCA, 10 ACA, 3 ACA, and diode test have 0%.

3. Relative to calibration standards.

4. The 10 A range is only available on a separate front panel connector. Add 2 mA base per amp for inputs greater than 5 Arms. 5. Add this for each °C outside TCAL ±5°C.

6. Add this for each °C outside the last TACAL ±2°C.

7. Add this for each °C outside TACAL ±2°C.

8. Specifications are for 4-wire ohms function or 2-wire ohms function using math null for offset. Without math null, add 0.2 Ω additional error in 2-wire ohms function. The 100 MΩ and 1 GΩ ranges are 2-wire only. See the manual for low power ohms specification and measurement currents.

9. For each additional volt over ±500 V add 0.02 mV of error.

10. Specifications are for the voltage measured at the input terminals. The 1 mA test current is typical. Variation in the current source will create some variation in the voltage drop across a diode junction.

11. See user manual for details.

12. Actual measurement range and probe errors will be limited by the selected probe. Probe accuracy adder includes all measurement and ITS-90 temperature conversion errors. PT100 Ro settable to 100Ω ± 5Ω to remove the initial probe error.

13. The internal reference junction uses the U1180A or equivalent adapter. This has a typical performance of ±1.0°C. This internal reference junction can be adjusted for better accuracy. An external reference junction can also be used.

14. Specifications are for sine wave input > 0.3% of range and > 1 mVrms. 750 ACV range limited to 8 x 107 V.Hz. For each additional volt over 300 Vrms add 1 mVrms of error.

15. Low-frequency performance: three filter settings are available: 3 Hz, 20 Hz, 200 Hz. Frequencies greater than these filter settings are specified with no additional errors.

16. Specifications are for sine wave input > 1% of range and > 10 µArms.

17. Specifications are for sine wave input unless stated otherwise.

18. Square wave input specified for 10 Hz to 300 kHz for 1 second aperture. For shorter apertures, the minimum frequency requires > 2 cycles.

19. Input > 100 mV. For 10 mV to 100 mV inputs, multiply % of reading error x10. Amplitude 10% to 120% of range except 14% to 100% for the 750 ACV range. Specifications are for 1-second gate time (7 digits).

20. Specifications are for using Math Null zeroing. High dissipation factor capacitors may show different results than a single frequency measurement. Film capacitors usually have lower dissipation factors than other dielectrics.

21. The second burden voltage can be obtained by using the 10 A input range.

22. Sample rate (actual): 50.118 kHz (Aperture = 19.953 µs). 23. Thermistor type: 2.2 kΩ (model number 44004), 5 kΩ (model number 44007) and 10 kΩ (model number 44006)

Highlights of Keysight Agilent 34470A

  • Histogram, bar and trend charts on 4.3-inch color graphical display ease monitoring and speed up statistical analysis.
  • Measure with confidence, with high basic DCV accuracy of 16 ppm.
  • Test low power devices with 1 µA range and pA resolution.
  • Flexibly automate measurements over USB or LAN/LXI core interface.
  • Digitizing and advanced triggering (DIG) now included.
  • Download BenchVue Basic app for free to control your instruments.

Get more insight quickly by 34470A:

Truevolt DMM's graphical capabilities such as trend and histogram charts offer more insights quickly. Both models also provide a data logging mode for easier trend analysis and a digitizing mode for capturing transients.


Measure low-power devices by 34470A:

The ability to measure very low current, 1 µA range with
pA resolution, allows you to make measurements on very low power devices.

Maintain calibrated measurements by 34470A:

Auto calibration allows you to compensate for temperature drift so you can maintain measurement accuracy throughout your workday.

List of Options of Keysight 34470A
100100-volt ac line selection
120120-volt ac line selection
220220-volt ac line selection
240240-volt ac line selection
DIGDigitizing and Advanced Triggering for 34470A Truevolt DMM license
GPBGPIB interface module for Truevolt series DMMs
MEM2M Memory for 34470A Truevolt DMM license
SECNISPOM and file security for Truevolt series DMMs license
Z540ANSI/NCSL Z540.3-2006 Calibration

FAQ:

1.Can you ship order to Canada or Australia?
Yes,we can .We send orders worldwide.

2. What delivery method do you use? and delivery time?

We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.

3. What is your payment term?

100% T/T payment before shipment.

4. How can I ask any other question?

You can contact us online or leave us messages below.



China Agilent Keysight 34470A Digital Multimeter 7.5 Digit Truevolt DMM Benchtop / Rackmount supplier

Agilent Keysight 34470A Digital Multimeter 7.5 Digit Truevolt DMM Benchtop / Rackmount

Inquiry Cart 0