50Hz/60Hz 220V AC DC Reactor , Electric Multifunctional VFD Line Choke

Brand Name:K-EASY
Certification:CE And ISO Certificated
Model Number:Inverter AC intput reactor
Minimum Order Quantity:1pcs
Delivery Time:1~7days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Shenzhen China
Address: Wisdom Lmgyu, baishixia community, Fuyong street, Bao 'an District, Shenzhen, China
Supplier`s last login times: within 34 hours
Product Details Company Profile
Product Details

AC 50/60Hz To Enjoy High Reputation H Insulation Class De Pirolisi High Pressure Input Reactor Warranty 36 Months 220V


Gemeral


This product adopted high quality foreign silicone steel sheet and copper wire being processed by use of advanced technology, with such features as small size, low temperature rise, no noise and etc. it is generally installed on the input side of inverter DC speed regulator, able to restrict the harmonic contents produced by inverter and entered into power network, and reduce the interference on other devices, improve the electricity quality and power factor, limit the abnormal fluctuation of system voltage and surging current, optimize wave and etc.


Main Technical Data

Voltage drop:1%-2%

Rated operating voltage: 380V/50Hz

Electric strength: iron core-winding 2500VAC/50Hz/10mA/60s no arcing no breakdown;

Insulation resistance: 1000VDC

Insulation resistance ≥100MV

Noise of reactor: less than 35dB (measured from 1 meter away in horizon from reactor)

Temperature rise less than 60K

Applicable standard: IEC289: 1987 "Reactors"

GB10229-88(eqv IEC289:1987)

GB10229-88"Reactors"(eqv IEC289:1987)

JB9644-1999"Reactor for semi-conductive electric driving use"


Voltage RangeDC500V-1000V
Dielectric StrengthCore-Winding, AC 3000V/50Hz/5mA, free of damage in 60s
Insultalon ResistanceCore-Winding, DC 1000V, Resistance > 100M ohm
Reactor's noiseless than 65dB(to be measured at the point 1 meter away from the reactor horizontally)
StandardGB 19212.1-2008 GB/T 1094.6-2011

Brand: K-Drive
Certificate: CE, RoHS



Why choose K-Drive products?

In the trend of advocating smart and simple industrial automation, environmentally friendly products, value-added solutions, K-Drive, as one of the world's leading drive manufacturers aggressively investing in R&D, production, and continuous quality improvement, is well positioned to provide its customers with technology-driven, performance-outstanding products such as VFDs, wind power converters, servo drives, HEV/EV drives, helping its customers save energy and increase industrial productivity with sustainability on the one hand, and enhancing their entire value-chain quality, delivery, and services on the other hand.


Production

In production, rigorous quality control is implemented on components, circuit boards, and the finished goods, assuring products without defects.



Packaging and logistics

All drives are well packed before shipment, fit for air shipment, sea transportation, and express delivery. Customers are able to call its own nominated forwarder or consult K-Drive logistics department for worldwide shipment services.

* Low-power inverters are packed in cardboard box, and others are in plywood cases.

* Plenty of transportation procurable globally in accordance with customer demand or K-Drive expertise.


How to select inverter dc reactor ?

Selecting an inverter DC reactor requires consideration of several factors. Here are some steps you can follow to select an appropriate inverter DC reactor:

  1. Determine the voltage and current ratings of your inverter system: The DC reactor should be selected based on the voltage and current ratings of the inverter system. This will ensure that the reactor can handle the power levels of your system.

  2. Determine the type of DC reactor you need: There are two main types of DC reactors - line reactors and load reactors. Line reactors are used to smooth out the current waveform and reduce harmonics in the power system, while load reactors are used to protect the inverter from short-circuit currents.

  3. Calculate the required inductance: The inductance of the DC reactor should be calculated based on the voltage and current ratings of the system. The inductance value is typically expressed in Henrys (H).

  4. Determine the rated current of the DC reactor: The rated current of the DC reactor should be selected based on the maximum current that will flow through it. This will ensure that the reactor can handle the current levels of your system without overheating.

  5. Choose a DC reactor that meets your requirements: Once you have determined the voltage and current ratings, the type of reactor, the required inductance, and the rated current, you can select a DC reactor that meets your requirements.

It is important to consult with a qualified engineer or supplier to ensure that the DC reactor you select is appropriate for your specific application. They can also assist you in calculating the required values and selecting a suitable product.