Float service:
Every month, recommend inspection every battery voltage.
Every three months, recommend equalization charge for one
time.Equalization charge method: Step 1:Discharge: 100% rate
capacity discharge.
Step 2:Charge: Max. Current 0.3CA, constant voltage 2.40-2.45V/Cell
charge 24h.
Cycle service:
Avoid battery over discharge,especially battery sereis connection
use.
Charged with recommend voltage,ensure battery can be full
recharged.
Ingeneral,recharge capacity should be 1.1~1.15 times discharge
capacity.
Length of service life will be directly affected by the number of
discharge cycles, depth of discharge, Ambient temperature and
charging voltage.
Charge the batteries at least once every six months, if they are
stored at 25℃.Charging Method:
ConstantVoltage:-0.2C×2h+2.40~2.45V/cell×24h,Max.Current0.25CA
ConstantCurrent:-0.2C×2h+0.1C×12h
Fast:-0.2C×2h+0.3C×4h
Terminal of torque: