Rosemount 3144P Input/output isolation specified to 500 Vdc 50/60
Hz 0–99 percent relative humidity
Product Description :
■ Superior accuracy and stability
■ Dual and single sensor capability with universal sensor inputs
(RTD, thermocouple, mV, ohms)
■ Comprehensive sensor and process diagnostics offering
■ SIL3 capable: IEC 61508 certified by an accredited third party
agency for use in safety instrumented systems up to SIL 3 (minimum
requirement of single use [1oo1] for SIL 2 and redundant use [1oo2]
for SIL 3)
■ Dual-compartment housing
■ Large LCD display
■ 4–20 mA HART® with selectable revisions (5 and 7)
■ FOUNDATION™ Fieldbus, compliant to ITK 6.0 and NE107 standards
■ Temperature measurement assembly with Rosemount X-well Technology
(option code PT)
■ Dual and single sensor input capabilities
■ Transmitter-sensor matching (option code C2)
■ Integral transient protector (option code T1)
■ IEC 61508 Safety Certificate of Compliance (option code QT)
■ Advanced sensor and process diagnostics (option codes D01 and
DA1)
Rosemount™ 3051S MultiVariable™ Transmitter
RangedownUp to 200:1
Communication Protocol4-20 mA HART™, WirelessHART®,
FOUNDATION™ FieldbusMeasurement RangeUp to 2000 psi (138 bar)
differential, Up to 6092 psi (420 bar) staticProcess
Wetted Material316L SST, Alloy C-276, Tantalum, Gold-plated 316L
SST
DiagnosticsBasic DiagnosticsCertifications/ApprovalsNSF, NACE™,
hazardous location, see full specs for complete list of
certifications
Description of Rosemount 3051L/CFP/CFC/CFA/T :
Rosemount 3051CFP Integral Orifice Flow Meters enable highly accurate flow
measurement in small line sizes. Internal pipe diameter variation
in combination with plate centering issues can greatly magnify flow
measurement errors in small line sizes. Integral Orifice Flow
Meters use a precision honed pipe section to minimize internal pipe
diameter variation along with a selfcentering plate design to
eliminate alignment errors.
■ Up to 1.75 percent of flow rate accuracy.
■ Available in ½- to 1½-in. (15 - 40 mm) line sizes.
■ Fully assembled and leak tested for out-of-the-box installation.
■ Simplified flow configuration with clearly displayed flow rate
and added totalizer (code M6, BLE, D1, DA1, T9, or RK).
■ Loop Integrity and Plugged Impulse Line Diagnostics detect issues
that might compromise the integrity of the output signal (code
DA1).
■ Bluetooth enables efficient, reliable, and safe configuration and
maintenance (code BLE).
■ Back-lit Graphical Display with Local Language Capability (code
M6).
■ Safety certification and proof testing
Rosemount 3051CFC Compact Flow Meters provide a quick, reliable installation between
existing raised face flanges. Depending on your application needs,
you can reduce energy loss with the Compact Annubar™ or minimize
straight run requirements with the Conditioning Orifice.
■ Up to 1.75 percent of flow rate accuracy.
■ Available in ½- to 12-in. (15 to 300 mm) line sizes.
■ Fully assembled and leak tested for out-of-the-box installation.
■ Simplified flow configuration with clearly displayed flow rate
and added totalizer (code M6, BLE, D1, DA1, T9, or RK).
■ Loop Integrity and Plugged Impulse Line Diagnostics detect issues
that might compromise the integrity of the output signal (code
DA1).
■ Bluetooth enables efficient, reliable, and safe configuration and
maintenance (code BLE).
■ Back-lit Graphical Display with Local Language Capability (code
M6).
■ Safety certification and proof testing
The Rosemount 3051CFA Annubar Flow Meter uses the T-shaped sensor design that delivers
best in class accuracy and performance while meeting the needs of
diverse process applications, whether it is high accuracy for
precision control or high strength for severe flow applications.
■ Up to 1.8 percent of flow rate accuracy.
■ Available in 2- to 96-in. (50 to 2400 mm) line.
■ Fully assembled and leak tested for out-of-the-box installation.
■ Simplified flow configuration with clearly displayed flow rate
and added totalizer (code M6, BLE, D1, DA1, T9, or RK).
■ Loop Integrity and Plugged Impulse Line Diagnostics detect issues
that might compromise the integrity of the output signal (code
DA1).
■ Bluetooth enables efficient, reliable, and safe configuration and
maintenance (code BLE).
■ Back-lit Graphical Display with Local Language Capability (code
M6).
■ Safety certification and proof testing
Rosemount 3051T In-Line Pressure Transmitters are the industry standard for gage
and absolute pressure measurement. The in-line, compact design
allows the transmitter to be connected directly to a process for
quick, easy and cost effective installation.
■ Loop Integrity and Plugged Impulse Line Diagnostics detect issues
that might compromise the integrity of the output signal (code
DA1).
■ Bluetooth® Connectivity enables efficient, reliable, and safe
configuration and maintenance (code BLE).
■ Back-lit Graphical Display with Local Language Capability
More information:
Description | Part number |
Rosemount 644HARTLCD display(option M 5-for use with options J 1-J 2) | 00644-7730-0111 |
Rosemount 644HARTLOI(option M 4) | 00644-7730-1011 |
Rosemount 644HARTLOI(option M 4-for use with options J 1-J 2) | 00644-7730-1111 |
Rosemount 644 FouNDATION Fieldbus LCD display(option M 5) | 00644-4430-0001 |
Rosemount 644PROFIBUSPALCD display(option M 5) | 00644-4430-0001 |
Rosemount 644HART Legacy display kit(option M 5) | 00644-4430-0001 |
Display with SST meter cover | |
Rosemount 644HARTLCD display(option M 5) (1) | 00644-7730-0021 |
Rosemount 644HARTLCD display(option M 5) (2) | 00644-7730-0121 |
Rosemount 644HARTLOI(option M 4) () | 00644-7730-1021 |
Rosemount 644HARTLOI(option M 4) (2) | 00644-7730-1121 |
Rosemount 644 FouNDATION Fieldbus LCD display(option M 5(1) | 00644-4430-0011 |
Rosemount 644PROFIBUSPALCD display(option M 5) (1) | 00644-4430-0011 |
Rosemount 644HART Legacy display kit(option M 5) () | 00644-4430-0011 |
Description | Part number |
Universal head, SST, display cover, 2-conduit-%-14NPT entries | 00644-4433-0101 |
Connection head, aluminum, standard cover, 2-conduit-M 20×%AN PT entries | 00644-4410-0021 |
Connection head, aluminum, disply cover, 2-conduit-M20x%AN PT entries | 00644-4410-0121 |
Connection head, aluminum, standard cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4410-001 |
Connection head, aluminum, display cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4410-0111 |
Connection head, SST, standard cover, 2-conduit-M 20×%AN PT entries | 00644-4411-0021 |
Connection head, SST, display cover, 2-conduit-M 20×%AN PT entries | 00644-4411-0121 |
Connection head, SST, standard cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4411-0011 |
Connection head, SST, display cover, 2-conduit-%-14NPT×%AN PT entries | 00644-4411-0111 |
Connection head, polished SST, standard cover, 2-conduit-M 20×1.5 entries | 00079-0312-0033 |
Connection head, pol shedS ST, display cover, 2-conduit-M20x 1.5 entries | 00079-0312-0133 |
Connection head, polished SST, standard cover, 2-conduit-M 20×1.5/M 24×1.5 entries | 00079-0312-0034 |
Connection head, polished SST, display cover, 2-conduit-M 20×1.5/M 24×1.5 entries | 00079-0312-0134 |
Connection head, polished SST, standard cover, 2-conduit-%-14NPT entries | 00079-0312-0011 |
Connection head, polished SST, display cover, 2-conduit-%-14NPT entries | 00079-0312-0111 |
Connection head, polished SST, standard cover, 2-conduit-%-14NPSM entries | 00079-0312-0022 |
Connection head, polished SST, display cover, 2-conduit-%-14NPSM entries | 00079-0312-0122 |
Universal head, aluminum, standard cover, 3-conduit-M 20 entries | 00644-4439-0001 |
Universal head, aluminum, display cover, 3-conduit-M 20 entries | 00644-4439-0101 |
Universal head, aluminum, standard cover, 3-conduit-%-14NPT entries | 00644-4439-0002 |
Universal head, aluminum, display cover, 3-conduit-%-14NPT entries | 00644-4439-0102 |
Universal head, SST, standard cover, 3-conduit-M 20 entries | 00644-4439-0003 |
Universal head, SST, display cover, 3-conduit-M 20 entries | 00644-4439-0103 |
Universal head, SST, standard cover, 3-conduit-%-14NPT entries | 00644-4439-0004 |
Universal head, SST, display cover, 3-conduit-%-14NPT entries | 00644-4439-0104 |
Features:
Industry-leading accuracy and reliability for best performance in
critical control and safety applications
Transmitter-sensor matching improves measurement accuracy up to 75%
Rosemount X-well Technology measures temperature without a process
penetration for reduced design, installation and maintenance costs
Dual compartment housing provides superior protection in harsh
environments
Hot Backup™ capability and sensor drift alert utilizing dual
sensors ensure measurement integrity
Thermocouple degradation diagnostic monitors thermocouple health to
detect degradation before failure
Minimum and maximum temperature tracking allows monitoring of
temperature extremes for easy troubleshooting
Transmitter supports multiple protocols for integration in many
host environments across many industries
Device dashboards provide easy interface for simplified device
configuration and diagnostic troubleshooting
Description of Rosemount :
Our company:
Our brand:
1, First, send us the brand, model code/pic of the nameplate, the quantity for inquiry. Then we will send the quote to you. after confirming the model and the quantity, then we will the PI to you.
2, You can transfer by Paypal/ Western Union/Trade assurance/ T/T. When we received the payment, then we will start to prepare the order for you asap.