3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure

Brand Name:ROSEMOUNT
Certification:Does not supply
Model Number:3051CFADL060DCHPS2T100032AA1
Minimum Order Quantity:1 ea
Delivery Time:8 WEEKS
Payment Terms:T/T,PAYONEER
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China
Supplier`s last login times: within 16 hours
Product Details Company Profile
Product Details

3051CFADL060DCHPS2T100032AA1 Annubar Flow Meter Differential pressure


Product Information Of : 3051CFADL060DCHPS2T100032AA1

BrandEMERSON ROSEMOUNT
Model3051CFADL060DCHPS2T100032AA1
SUPPLY

6-in

SIZENo
WeightDoes not supply

The Rosemount 3051CFA Annubar Flow Meter uses the T-shaped sensor design that delivers best in class accuracy and performance while meeting the needs of diverse process applications, whether it is high accuracy for precision control or high strength for severe flow applications. Main capabilities include:
■Up to 1.8 percent of flow rate accuracy.
■Available in 2- to 96-in. (50 to 2400 mm) line.
■Fully assembled and leak tested for out-of-the-box installation.
■The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
■LOI with straightforward menus and built-in configuration buttons (option code M4).


More options :

3051CG3A02A1AB1H2L4M5K5

3051CG4A02A1AB1H2L4M5K5

3051CG5A02A1AB1H2L4M5K5

3051CG4A02A1AB1H2L4M5I5

3051CG4A02A1AB1H2L4M5E5

3051CG3A02A1AB1H2L4M5I5

3051CG1A02A1AB1H2L4M5E5

3051CG2A02A1AB1H2L4M5E5

3051CG3A02A1AB1H2L4M5E5

3051CG5A02A1AB1H2L4M5E5

3051CG1A02A1AB1H2L4M5I5

3051CG2A02A1AB1H2L4M5I5


A06B-6058-H004

A06B-6058-H005

A06B-6058-H006

A06B-6045-H003

A06B-0061-B503

A06B-6045-H004

A06B-6047-H003

A06B-6047-H004

A06B-6050-H112

A06B-6050-H113

A06B-0061-B203

A06B-0371-B157

A06B-0373-B175

A06B-0123-B175

A06B-0501-B002

A06B-0502-B201


Rosemount 3051CFA Annubar Flow Meter Information:

ModelProduct description
3051CFARosemount Annubar Flow Meter
Measurement type
DDifferential pressure
Fluid type
LLiquid
GGas
SSteam
Line size
0202-in. (50 mm)
0252½-in. (63.5 mm)
0303-in. (80 mm)
0353½-in. (89 mm)
0404-in. (100 mm)
0505-in. (125 mm)
0606-in. (150 mm)
0707-in. (175 mm)
0808-in. (200 mm)
10010-in. (250 mm)
12012-in. (300 mm)
14014-in. (350 mm)
16016-in. (400 mm)
18018-in. (450 mm)
20020-in. (500 mm)
24024-in. (600 mm)
30030-in. (750 mm)
36036-in. (900 mm)
42042-in. (1066 mm)
48048-in. (1210 mm)
60060-in. (1520 mm)
72072-in. (1820 mm)
78078-in (1950 mm)
84084-in. (2100 mm)
90090-in. (2250 mm)
96096-in (2400 mm)
Pipe I.D. range
ZSpecify pipe I.D. and wall thickness
Pipe material/mounting assembly material
CCS (A105)
S316 SST
0No mounting (customer supplied)
GChrome-moly grade F-11
NChrome-moly grade F-22
JChrome-moly grade F-91
Piping orientation
HHorizontal piping
DVertical piping with downwards flow
UVertical piping with upwards flow
Annubar type
PPak-Lok
FFlanged with opposite side support
LFlange-Lok
GGear-drive Flo-Tap
MManual Flo-Tap
Sensor material
S316 SST
HAlloy C-276
Sensor size
1Sensor size 1 — line sizes 2- to 8-in. (50 to 200 mm)
2Sensor size 2 — line sizes 6- to 96-in. (150 to 2400 mm)
3Sensor size 3 — line sizes greater than 12-in. (300 mm)
Mounting type
T1Compression or threaded connection
A1Class 150 RF ANSI
A3Class 300 RF ANSI
A6Class 600RF ANSI
D1DN PN16 flange
D3DN PN40 flange
D6DN PN100 flange
A9(1)Class 900 RF ANSI
AF(1)Class 1500 RF ANSI
AT(1)Class 2500 RF ANSI
R1Class 150 RTJ flange
R3Class 300 RTJ flange
R6Class 600RTJ flange
R9(1)Class 900 RTJ flange
RF(1)Class 1500 RTJ flange
RT(1)Class 2500 RTJ flange
Opposite side support or packing gland
0No opposite side support or packing gland (required for Pak-Lok and Flange-Lok models)
Opposite side support – required for flanged models
CNPT threaded opposite support assembly – extended tip
DWelded opposite support assembly – extended tip
Packing gland – required for Flo-Tap models
Packing gland materialRod materialPacking material
J(2)SST packing gland/cage nippleCSPTFE
K(2)SST packing gland/cage nippleSSTPTFE
L(2)SST packing gland/cage nippleCSGraphite
N(2)SST packing gland/cage nippleSSTGraphite
RAlloy C-276 packing gland/cage nippleSSTGraphite
Isolation valve for Flo-Tap models
0Not applicable or customer supplied
1Gate valve, CS
2Gate valve, SST
5Ball valve, CS
6Ball valve, SST
Temperature measurement
TIntegral RTD – not available with flanged model greater than Class 600
0No temperature sensor
RRemote Thermowell and RTD
Transmitter connection platform
3Direct-mount, integral 3-valve manifold– not available with flanged model greater than Class 600
5Direct-mount, 5-valve manifold – not available with flanged model greater than Class 600
7Remote-mount NPT connections (½-in. NPT)
6Direct-mount, high temperature 5-valve manifold – not available with flanged model greater than Class 600
8Remote-mount SW connections (½-in.)
Differential pressure range
10 to 25 in H2O (0 to 62,16 mbar)
20 to 250 in H2O (0 to 621,60 mbar)
30 to 1000 in H2O (0 to 2,48 bar)
Transmitter output
A(3)4–20 mA with digital signal based on HART® Protocol
FFOUNDATION™ Fieldbus Protocol
W(4)PROFIBUS® PA Protocol
X(5)Wireless (requires wireless options and engineered polymer housing)
M(6)Low-power 1–5 Vdc with digital signal based on HART Protocol
Transmitter housing materialConduit entry size
AAluminum½–14 NPT
BAluminumM20 x 1.5
JSST½–14 NPT
EAluminum, ultra copper low½–14 NPT
FAluminum, ultra copper lowM20 x 1.5
KSSTM20 x 1.5
P(7)Engineered polymerNo conduit entries
D(8)Aluminum
M(8)SST
Transmitter performance class
11.8 percent flow rate accuracy, 8:1 flow turndown, 5-yr. stability
Wireless options (requires wireless output code X and Engineered Polymer Housing Code P)
Wireless transmit rate, operating frequency, and protocol
WA3User configurable transmit rate, 2.4 GHz WirelessHART
Antenna and SmartPower
WP5Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)
Options (include with selected model number)
Extended product warranty
WR33-year limited warranty
WR55-year limited warranty
Pressure testing(9)
P1Hydrostatic testing with certificate
PXExtended hydrostatic testing
Special cleaning
P2Cleaning for special services
PACleaning per ASTM G93 Level D (section 11.4)
Material testing
V1Dye penetrant exam
Material examination
V2Radiographic examination
Flow calibration
W1Flow calibration (Average K)
Special inspection
QC1Visual and dimensional inspection with certificate
QC7Inspection and performance certificate
Surface finish
RLSurface finish for low pipe Reynolds number in gas and steam
RHSurface finish for high pipe Reynolds number in liquid
Material traceability certification(10)
Q8Material Traceability Certification per EN 10474:2004 3.1
Code conformance(11)
J2ANSI/ASME B31.1
J3ANSI/ASME B31.3
Materials conformance(12)
J5NACE MR-0175 / ISO 15156
Country certification
J6European Pressure Directive (PED)
J1Canadian Registration
Installed in flanged pipe spool section
H3Class 150 flanged connection with Rosemount standard length and schedule
H4Class 300 flanged connection with Rosemount standard length and schedule
H5Class 600 flanged connection with Rosemount standard length and schedule
Instrument connections for remote mount options
G2Needle valves, SST
G6OS&Y gate valve, SST
G1Needle valves, CS
G3Needle valves, alloy C-276
G5OS&Y gate valve, CS
G7OS&Y gate valve, alloy C-276
Special shipment
Y1Mounting hardware shipped separately
Special dimensions
VMVariable mounting
VTVariable tip
VSVariable length spool section
Plantweb control functionality(13)
A01FOUNDATION Fieldbus control function block suite
Plantweb diagnostic functionality
DA0(14)Loop Integrity HART diagnostic
D01(13)FOUNDATION Fieldbus diagnostics suite
Product certifications
E8ATEX Flameproof, Dust
I1(15)ATEX Intrinsic Safety and Dust
IAATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
N1ATEX Type n and Dust
K8ATEX Flameproof, Intrinsic Safety, Type n, Dust (combination of E8, I1, and N1)
E5FM Explosion-proof, Dust Ignition-proof
I5(16)FM Intrinsically Safe, Nonincendive
IEFM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
K5FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of E5 and I5)
C6CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
I6(7)CSA Intrinsically Safe
K6CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)
E7IECEx Flameproof, Dust Ignition-proof
I7IECEx Intrinsic Safety
N7IECEx Type n
K7IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
E2INMETRO Flameproof
I2INMETRO Intrinsic Safety
IBINMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
K2INMETRO Flameproof, Intrinsic Safety
E3China Flameproof
I3China Intrinsic Safety
KBFM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
KDCSA, FM, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
Sensor fill fluid and O-ring options
L1(17)Inert sensor fill fluid (silicone fill fluid is standard)
L2Graphite-filled (PTFE) O-ring
LA(17)Inert sensor fill fluid and graphite-filled (PTFE) O-ring
Shipboard approvals(17)
SBSAmerican Bureau of Shipping
SLL(18)Lloyds Register (LR)
Display and interface options
M4(19)LCD display with LOI
M5LCD display
Transmitter calibration certification
Q4Calibration certificate for transmitter
Quality certification for safety(14)
QSPrior-use certificate of FMEDA data
QTSafety certified to IEC 61508 with certificate of FMEDA
Transient protection(17) (20)
T1Transient terminal block
Manifold for remote mount option
F23-valve manifold, SST
F65-valve manifold, SST
F13-valve manifold, CS
F33-valve manifold, alloy C-276
F55-valve manifold, CS
F75-valve manifold, alloy C-276
Lower power output
C20.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)
Alarm levels(14)
C4(21)NAMUR alarm and saturation levels, high alarm
CN(21)NAMUR alarm and saturation levels, low alarm
CRCustom alarm and saturation signal levels, high alarm
CSCustom alarm and saturation signal levels, low alarm
CTRosemount standard low alarm
Configuration buttons
D4(14)Analog zero and span
DZ(22)Digital zero trim
Ground screw(17)(23)
V5External ground screw assembly
HART Revision configuration (requires HART Protocol output code A)(3)
HR5Configured for HART Revision 5
HR7Configured for HART Revision 7
Typical model number: 3051CFA D L 060 D C H P S 2 T1 0 0 0 3 2 A A 1

Good Service in WTL:
> We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
> Please send your RFQ to get the latest price.
> Normally, we will ship the items in 1-2 weeks after receive the payment.
> We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
> We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.

If needed, please contact us for specific prices.


OUR MAIN BRAND:

China 3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure supplier

3051CFADL060DCHPS2T100032AA1 Pressure Temperature Transmitter Annubar Flow Meter Differential Pressure

Inquiry Cart 0