Home /Pharmaceutical Machinery /

3051CFPDS010W1S0500D32AA1E5M5 Pressure Temperature Transmitter

3051CFPDS010W1S0500D32AA1E5M5 Pressure Temperature Transmitter

Brand Name:ROSEMOUNT
Certification:Does not supply
Model Number:3051CFPDS010W1S0500D32AA1E5M5
Minimum Order Quantity:1 ea
Delivery Time:8 WEEKS
Payment Terms:T/T,PAYONEER
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China
Supplier`s last login times: within 16 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

3051CFPDS010W1S0500D32AA1E5M5 Integral Orifice Flow Meter 3051CFP Transmitter


Product Information Of : 3051CFPDS010W1S0500D32AA1E5M5

Brand3051CFPDS010W1S0500D32AA1E5M5
SUPPLY

0 to 621,60 mbar

SIZENo
WeightDoes not supply

Rosemount 3051CFP Integral Orifice Flow Meters enable highly accurate flow measurement in small line sizes. Integral Orifice Flow Meters use precision honed pipe section for increased accuracy and self-centering plate design to prevent alignment errors that magnify measurement inaccuracies in small line sizes.
■Up to 1.75 percent of flow rate accuracy.
■Available in ½- to 1½-in. (15 - 40 mm) line sizes.
■Fully assembled and leak tested for out-of-the-box installation.
■The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
■LOI with straightforward menus and built-in configuration buttons (option code M4).


More options :

SGDA-04BS

SGDA-04VP

SGDA-04VP

SGDA-04VS

SGDA-05ADG+SGMG-05A2A

SGDA-08AP

SGDA-08APP

SGDA-08APPY128

SGDA-08AS

SGDA-08ASP

SGDA-08ASP SGDA-08AS

SGDA-08VP

SGD-A3AN

SGD-A5AN

SGD-A5BH

SGDA-A3AP

SGDA-A3BPM

SGDA-A3BS

SGDA-A3BS

SGDA-A3CPY14


MR-J2S-350B-EG117

MDS-B-SVJ2-01

MDS-B-SVJ2-03

MDS-B-SVJ2-04

MDS-B-SVJ2-06

MDS-B-SVJ2-10

MDS-B-SVJ2-20

MDS-B-SVJ2-07

MDS-D-SVJ3-01NA

MDS-D-SVJ3-02NA

MDS-D-SVJ3-07NA

MDS-D-SVJ3-10NA

MDS-D-SVJ3-20NA


Rosemount 3051CFP Integral Orifice Flow Meter​ Information:

ModelProduct description
3051CFPIntegral orifice flow meter
Measurement type
DDifferential pressure
Body material
S316 SST
Line size
005½-in. (15 mm)
0101-in. (25 mm)
0151½-in. (40 mm)
Process connection
T1NPT female body (not available with remote thermowell and RTD)
S1(1)Socket weld body (not available with remote thermowell and RTD)
P1Pipe ends: NPT threaded
P2Pipe ends: beveled
D1Pipe ends: Flanged, DIN PN16, slip-on
D2Pipe ends: Flanged, DIN PN40, slip-on
D3Pipe ends: Flanged, DIN PN100, slip-on
W1Pipe ends: Flanged, RF, ANSI Class 150, weld-neck
W3Pipe ends: Flanged, RF, ANSI Class 300, weld-neck
W6Pipe ends: Flanged, RF, ANSI Class 600, weld-neck
A1Pipe ends: Flanged, RF, ANSI Class 150, slip-on
A3Pipe ends: Flanged, RF, ANSI Class 300, slip-on
A6Pipe ends: Flanged, RF, ANSI Class 600, slip-on
R1Pipe ends: Flanged, RTJ, ANSI Class 150, slip-on
R3Pipe ends: Flanged, RTJ, ANSI Class 300, slip-on
R6Pipe ends: Flanged, RTJ, ANSI Class 600, slip-on
Orifice plate material
S316 SST
HAlloy C-276
MAlloy 400
Bore size option
00660.066-in. (1.68 mm) for ½-in. pipe
01090.109-in. (2.77 mm) for ½-in. pipe
01600.160-in. (4.06 mm) for ½-in. pipe
01960.196-in. (4.98 mm) for ½-in. pipe
02600.260-in. (6.60 mm) for ½-in. pipe
03400.340-in. (8.64 mm) for ½-in. pipe
01500.150-in. (3.81 mm) for 1-in. pipe
02500.250-in. (6.35 mm) for 1-in. pipe
03450.345-in. (8.76 mm) for 1-in. Pipe
05000.500-in. (12.70 mm) for 1-in. pipe
06300.630-in. (16.00 mm) for 1-in. pipe
08000.800-in. (20.32 mm) for 1-in. pipe
02950.295-in. (7.49 mm) for 1½-in. pipe
03760.376-in. (9.55 mm) for 1½-in. pipe
05120.512-in. (13.00 mm) for 1½-in. pipe
07480.748-in. (19.00 mm) for 1½-in. pipe
10221.022-in. (25.96 mm) for 1½-in. pipe
11841.184-in. (30.07 mm) for 1½-in. pipe
00100.010-in. (0.25 mm) for ½-in. pipe
00140.014-in. (0.36 mm) for ½-in. pipe
00200.020-in. (0.51 mm) for ½-in. pipe
00340.034-in. (0.86 mm) for ½-in. pipe
Transmitter connection platform
D3Direct-mount, 3-valve manifold, SST
D5Direct-mount, 5-valve manifold, SST
R3Remote-mount, 3-valve manifold, SST
R5Remote-mount, 5-valve manifold, SST
D4Direct-mount, 3-valve manifold, alloy C-276
D6Direct-mount, 5-valve manifold, alloy C-276
D7Direct-mount, high temperature, 5-valve manifold, SST
R4Remote-mount, 3-valve manifold, alloy C-276
R6Remote-mount, 5-valve manifold, alloy C-276
Differential pressure ranges
10 to 25 in H2O (0 to 62,16 mbar)
20 to 250 in H2O (0 to 621,60 mbar)
30 to 1000 in H2O (0 to 2,48 bar)
Transmitter output
A(2)4–20 mA with digital signal based on HART® Protocol
FFOUNDATION™ Fieldbus Protocol
W(3)PROFIBUS® PA Protocol
X(4)Wireless
M(5)Low-power 1–5 Vdc with digital signal based on HART Protocol
Transmitter housing materialConduit entry size
AAluminum½–14 NPT
BAluminumM20 x 1.5
EAluminum, ultra low copper½–14 NPT
FAluminum, ultra low copperM20 x 1.5
JSST½–14 NPT
KSSTM20 x 1.5
P(6)Engineered polymerNo conduit entries
D(7)Aluminum
M(7)SST
Transmitter performance class
1up to ±1.8% flow rate accuracy, 8:1 flow turndown, 5-year stability
Wireless options (requires wireless output code X and engineered polymer housing code P)
Wireless transmit rate, operating frequency, and protocol
WA3User configurable transmit rate, 2.4GHz WirelessHART
Antenna and SmartPower
WP5Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)
Options (include with selected model number)
Extended product warranty
WR33-year limited warranty
WR55-year limited warranty
Transmitter body/bolt material
GTHigh temperature (850 °F/454 °C)
Temperature sensor(8)
RTThermowell and RTD
Optional connection
G1DIN 19213 transmitter connection
Pressure testing(9)
P1Hydrostatic testing with certificate
Special cleaning
P2Cleaning for special services
PACleaning per ASTM G93 level D (section 11.4)
Material testing
V1Dye penetrant exam
Material examination
V2Radiographic examination
Flow calibration(10)
WDDischarge coefficient verification
Special inspection
QC1Visual and dimensional inspection with certificate
QC7Inspection and performance certificate
Material traceability certification
Q8Material traceability certification per EN 10204:2004 3.1
Code conformance(11)
J2ANSI/ASME B31.1
J3ANSI/ASME B31.3
J4ANSI/ASME B31.8
Materials conformance(12)
J5NACE MR-0175/ISO 15156
Country certification
J6European Pressure Directive (PED)
J1Canadian Registration
Transmitter calibration certification
Q4Calibration Certificate for Transmitter
Quality certification for safety(13)
QSPrior-use certificate of FMEDA data
QTSafety certified to IEC 61508 with certificate of FMEDA
Product certifications
E8ATEX Flameproof, Dust
I1(14)ATEX Intrinsic Safety and Dust
IAATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
N1ATEX Type n and Dust
K8ATEX Flameproof, Intrinsic Safety, Type n, and Dust (combination of E8, I1, and N1)
E5FM Explosion-proof, Dust Ignition-proof
I5(15)FM Intrinsically Safe, Nonincendive
IEFM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
K5FM Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of E5 and I5)
C6CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
I6 (6)CSA Intrinsically Safe
K6CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)
E7IECEx Flameproof, Dust Ignition-proof
I7IECEx Intrinsic Safety
N7IECEx Type n
K7IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
E2INMETRO Flameproof
I2INMETRO Intrinsic Safety
IBINMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
K2INMETRO Flameproof, Intrinsic Safety
E3China Flameproof
I3China Intrinsic Safety
KBFM and CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
KDCSA, FM, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
Sensor fill fluid and O-ring options
L1(16)Inert sensor fill fluid
L2Graphite-filled (PTFE) O-ring
LA(16)Inert sensor fill fluid and graphite-filled (PTFE) O-ring
Shipboard approvals(16)
SBSAmerican Bureau of Shipping
SLL(17)Lloyds Register (LR)
Display and interface options
M4(18)LCD display with LOI
M5LCD display
Transient protection(16)(19)
T1Transient terminal block
Plantweb control functionality(20)
A01FOUNDATION Fieldbus control function block suite
Plantweb diagnostic functionality
DA0(13)Loop Integrity HART Diagnostic
D01(20)FOUNDATION Fieldbus diagnostic suite
Low power output
C20.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)
Alarm levels(13)
C4(21)NAMUR alarm and saturation levels, high alarm
CN(21)NAMUR alarm and saturation levels, low alarm
CRCustom alarm and saturation signal levels, high alarm
CSCustom alarm and saturation signal levels, low alarm
CTRosemount standard low alarm
Ground screw(16) (22)
V5External ground screw assembly
Configuration buttons
D4(13)Analog zero and span
DZ(23)Digital zero trim
Hart Revision configuration (requires HART Protocol output code A)(2)
HR5Configured for HART Revision 5
HR7Configured for HART Revision 7
Typical model number: 3051CFP D S 010 W1 S 0500 D3 2 A A 1 E5 M5

Good Service in WTL:
> We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
> Please send your RFQ to get the latest price.
> Normally, we will ship the items in 1-2 weeks after receive the payment.
> We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
> We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.

If needed, please contact us for specific prices.


OUR MAIN BRAND:

China 3051CFPDS010W1S0500D32AA1E5M5 Pressure Temperature Transmitter supplier

3051CFPDS010W1S0500D32AA1E5M5 Pressure Temperature Transmitter

Inquiry Cart 0