Home /Food & Beverage Machinery /

3051L2AA2AD21AADFE5 Level Transmitter Rosemount 3051 4 To 20mA

3051L2AA2AD21AADFE5 Level Transmitter Rosemount 3051 4 To 20mA

Brand Name:ROSEMOUNT
Certification:Does not supply
Model Number:3051L2AA2AD21AADFE5
Minimum Order Quantity:1 ea
Delivery Time:6 WEEKS
Payment Terms:T/T,PAYONEER
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen China
Address: 23E BlockB,Lushan Building,Chunfeng Road,Luohu District,Shenzhen,518001,China
Supplier`s last login times: within 16 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

3051L2AA2AD21AADFE5 Level Transmitter 4–20 mA Rosemount 3051L

Product Information Of : 3051L2AA2AD21AADFE5

Brand EMERSON ROSEMOUNT
Model 3051L2AA2AD21AADFE5
SUPPLY 4–20 mA
SIZE NOS
Weight 5KG

The Rosemount 3051L Level Transmitter combines the performance and capabilities of Rosemount 3051 Transmitters with the reliability and quality of a direct mount seal in one model number. Rosemount 3051L Level Transmitters offer a variety of process connections, configurations, and fill fluid types to meet a breadth of level applications. Capabilities of a Rosemount 3051L Level Transmitter include:
■Quantify and optimize total system performance (option code QZ).
■Tuned-system assembly (option code S1).
■The Loop Integrity Diagnostic continuously monitors the electrical loop to detect changes that compromise the integrity of the transmitted 4-20 mA output signal (Option Code DA0).
■LOI with straightforward menus and built-in configuration buttons (option code M4).

More options :

A20B-8200-0382

A20B-8200-0383

A20B-8200-0384

A20B-8200-0385

A20B-8200-0390

A20B-8200-0391

A20B-8200-0392

A20B-8200-0393

A20B-8200-0395

A20B-8200-0396

SGDH-10AE

SGDH-30AE

SGDP-A3APAY108

SGDS-01A01A

SGD-01AN+SGM-01A3NT14

SGD-01AHY130

SGD-01AS

SGD-01BH

SGD-01BP

SGD-02AH

SGD-02AHY500

SGD-02AN

Rosemount 3051L Level Transmitter Information:

Model Transmitter type
3051L Level transmitter
Pressure range
2 –250 to 250 in H2O (–621,60 to 621,60 mbar)
3 –1000 to 1000 in H2O (–2,48 to 2,48 bar)
4 –300 to 300 psi (–20,68 to 20,68 bar)
Transmitter output
A(1) 4–20 mA with digital signal based on HART® Protocol
F FOUNDATION™ Fieldbus Protocol
W(2) PROFIBUS® PA Protocol
X(3) Wireless (requires wireless options and engineered polymer housing)
M(4) Low-power 1–5 Vdc with digital signal based on HART Protocol
Process connection size, material, extension length (high side)
Code Process connection size Material Extension length
G0(5) 2-in./DN 50/A 316L SST Flush mount only
H0 (5) 2-in./DN 50 Alloy C-276 Flush mount only
J0 2-in./DN 50 Tantalum Flush mount only
A0(5) 3-in./DN 80 316L SST Flush mount
A2(5) 3-in./DN 80 316L SST 2-in./50 mm
A4(5) 3-in./DN 80 316L SST 4-in./100 mm
A6(5) 3-in./DN 80 316L SST 6-in./150 mm
B0(5) 4-in./DN 100 316L SST Flush mount
B2(5) 4-in./DN 100 316L SST 2-in./50 mm
B4(5) 4-in./DN 100 316L SST 4-in./100 mm
B6(5) 4-in./DN 100 316L SST 6-in./150 mm
C0(5) 3-in./DN 80 Alloy C-276 Flush mount
C2(5) 3-in./DN 80 Alloy C-276 2-in./50 mm
C4(5) 3-in./DN 80 Alloy C-276 4-in./100 mm
C6(5) 3-in./DN 80 Alloy C-276 6-in./150 mm
D0(5) 4-in./DN 100 Alloy C-276 Flush mount
D2(5) 4-in./DN 100 Alloy C-276 2-in./50 mm
D4(5) 4-in./DN 100 Alloy C-276 4-in./100 mm
D6(5) 4-in./DN 100 Alloy C-276 6-in./150 mm
E0 3-in./DN 80 Tantalum Flush mount only
F0 4-in./DN 100 Tantalum Flush mount only
Mounting flange size, rating, material (high side)
Size Rating Material
M 2-in. ANSI/ASME B16.5 Class 150 CS
A 3-in. ANSI/ASME B16.5 Class 150 CS
B 4-in. ANSI/ASME B16.5 Class 150 CS
N 2-in. ANSI/ASME B16.5 Class 300 CS
C 3-in. ANSI/ASME B16.5 Class 300 CS
D 4-in. ANSI/ASME B16.5 Class 300 CS
P 2-in. ANSI/ASME B16.5 Class 600 CS
E 3-in. ANSI/ASME B16.5 Class 600 CS
X(5) 2-in. ANSI/ASME B16.5 Class 150 316 SST
F(5) 3-in. ANSI/ASME B16.5 Class 150 316 SST
G(5) 4-in. ANSI/ASME B16.5 Class 150 316 SST
Y(5) 2-in. ANSI/ASME B16.5 Class 300 316 SST
H(5) 3-in. ANSI/ASME B16.5 Class 300 316 SST
J(5) 4-in. ANSI/ASME B16.5 Class 300 316 SST
Z(5) 2-in. ANSI/ASME B16.5 Class 600 316 SST
L(5) 3-in. ANSI/ASME B16.5 Class 600 316 SST
Q DN 50 PN 10-40 per EN 1092-1 CS
R DN 80 PN 40 per EN 1092-1 CS
S DN 100 PN 40 per EN 1092-1 CS
V DN 100 PN 10/16 per EN 1092-1 CS
K(5) DN 50 PN 10-40 per EN 1092-1 316 SST
T(5) DN 80 PN 40 per EN 1092-1 316 SST
U(5) DN 100 PN 40 per EN 1092-1 316 SST
W(5) DN 100 PN 10/16 per EN 1092-1 316 SST
7(5) 4 in. ANSI/ASME B16.5 Class 600 316 SST
1 N/A 10K per JIS B2238 CS
2 N/A 20K per JIS B2238 CS
3 N/A 40K per JIS B2238 CS
4(5) N/A 10K per JIS B2238 316 SST
5(5) N/A 20K per JIS B2238 316 SST
6(5) N/A 40K per JIS B2238 316 SST
Seal fill fluid (high side) Specific gravity Temperature limits (ambient temperature of 70° F [21° C])
D Silicone 200 0.93 –49 to 401 °F (–45 to 205 °C)
F Silicone 200 for vacuum applications 0.93 For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note.
L Dow Corning® 704 diffusion pump fluid 1.07 32 to 401 °F (0 to 205 °C)
C D.C. Silicone 704 for vacuum applications 1.07 For use in vacuum applications below 14.7 psia (1 bar-a), refer to vapor pressure curves in Rosemount DP Level Fill Fluid Specification Technical Note.
A SYLTHERM XLT 0.85 –102 to 293 °F (–75 to 145 °C)
H Inert (halocarbon) 1.85 –49 to 320 °F (–45 to 160 °C)
G Glycerin and water 1.13 5 to 203 °F (–15 to 95 °C)
N Neobee® M-20 0.92 5 to 401 °F (–15 to 205 °C)
P Propylene glycol and water 1.02 5 to 203 F (–15 to 95 °C)
Low pressure side
Configuration Flange adapter Diaphragm material Sensor fill fluid
11(5) Gage SST 316L SST Silicone
21 Differential SST 316L SST Silicone
22(5) Differential SST Alloy C-276 Silicone
2A(6) Differential SST 316L SST Inert (halocarbon)
2B(5) (6) Differential SST Alloy C-276 Inert (halocarbon)
31(5) Tuned-system assembly with remote seal None 316L SST Silicone (requires option code S1)
O-ring
A Glass-filled PTFE
Housing material Conduit entry size
A Aluminum ½–14 NPT
B Aluminum M20 x 1.5
E Aluminum, ultra low copper ½–14 NPT
F Aluminum, ultra low copper M20 x 1.5
J SST ½–14 NPT
K SST M20 x 1.5
P(7) Engineered polymer No conduit entries
D(8) Aluminum
M(8) SST
Wireless options (requires wireless output code X and Engineered Polymer Housing code P)
Wireless transmit rate, operating frequency, and protocol
WA3 User configurable transmit rate, 2.4 GHz WirelessHART
Antenna and SmartPower
WP5 Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately)
Options (include with selected model number)
Extended product warranty
WR3 3-year limited warranty
WR5 5-year limited warranty
Plantweb control functionality(9)
A01 FOUNDATION Fieldbus Control Function Block Suite
Plantweb diagnostic functionality
DA0(20) Loop Integrity HART Diagnostic
D01(9) FOUNDATION Fieldbus diagnostics suite
Seal assemblies(10)
S1 Assembled to One Rosemount 1199 Seal
Product certifications
E8 ATEX Flameproof and Dust Certification
I1(11) ATEX Intrinsic Safety and Dust
IA ATEX FISCO Intrinsic Safety; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
N1 ATEX Type n Certification and Dust
K8 ATEX Flameproof, Intrinsic Safety, Type n, and Dust (combination of E8, I1, and N1)
E4(12) TIIS Flameproof
E5 FM Explosion-proof, Dust Ignition-proof
I5(13) FM Intrinsically Safe, Nonincendive
IE FM FISCO Intrinsically Safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
K5 FM Explosion-proof, Dust Ignition-Proof, Intrinsically Safe, and Division 2
C6 CSA Explosion-proof, Dust Ignition-proof, Intrinsically Safe, and Division 2
I6(7) CSA Intrinsic Safety
K6 CSA and ATEX Explosion-proof, Intrinsically Safe, and Division 2 (combination of C6, E8, and I1)
E7 IECEx Flameproof, Dust Ignition-proof
I7 IECEx Intrinsic Safety
N7 IECEx Type n Certification
K7 IECEx Flameproof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
E2 INMETRO Flameproof
I2 INMETRO Intrinsic Safety
IB INMETRO FISCO intrinsically safe; for FOUNDATION Fieldbus or PROFIBUS PA Protocols only
K2 INMETRO Flameproof, Intrinsic Safety
E3 China Flameproof
I3 China Intrinsic Safety
N3 China Type n
EM Technical Regulations Customs Union (EAC) Flameproof
IM Technical Regulations Customs Union (EAC) Intrinsic Safety
KM Technical Regulations Customs Union (EAC) Flameproof and Intrinsic Safety
KB FM and CSA Explosion-proof, Dust Ignition Proof, Intrinsically Safe, and Division 2 (combination of K5 and C6)
KD FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of K5, C6, I1, and E8)
EP(14) Republic of Korea Flameproof
IP(15) Republic of Korea Intrinsic Safety
KP(16) Republic of Korea Flameproof, Intrinsic Safety
Shipboard approvals(7)
SBS American Bureau of Shipping
SBV(17) Bureau Veritas (BV)
SDN Det Norske Veritas
SLL(17) Lloyds Register (LR)
Bolting material
L4 Austenitic 316 SST bolts
L5 ASTM A 193, grade B7M bolts
L6 Alloy K-500 Bolts
L8 ASTM A 193 Class 2, grade B8M bolts
Display and interface options
M4(18) LCD display with LOI
M5 LCD display
Calibration certification
Q4 Calibration Certificate
QP Calibration Certificate and tamper evident seal
QG(19) Calibration Certificate and GOST Verification Certificate
Material traceability certification
Q8 Material Traceability Certification per EN 10204 3.1
Quality certification for safety(20)
QS Prior-use certificate of FMEDA data
QT Safety certified to IEC 61508 with certificate of FMEDA
Toolkit total system performance reports
QZ Seal system performance calculation report
Conduit electrical connector(6)
GE M12, 4-pin, male connector (eurofast)
GM A size Mini, 4-pin, male connector (minifast)
Configuration buttons
D4(20) Analog zero and span
DZ(21) Digital zero trim
Transient protection(6)(22)
T1 Transient protection
Software configuration(21)
C1

Custom Software Configuration

(For wired, see the Rosemount 3051 Configuration Data Sheet. For wireless, see the Rosemount 3051 Wireless Configuration Data Sheet.)

Low power output
C2 0.8–3.2 Vdc output with digital signal based on HART Protocol (available with output code M only)
Alarm levels(20)
C4(23) NAMUR alarm and saturation levels, high alarm
CN(23) NAMUR alarm and saturation levels, low alarm
CR Custom alarm and saturation signal levels, high alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)
CS Custom alarm and saturation signal levels, low alarm (requires C1 and Rosemount 3051 Configuration Data Sheet)
CT Rosemount Standard low alarm
Conduit plug
DO 316 SST Conduit Plug
Ground screw(6)(24)
V5 External ground screw assembly
Lower housing flushing connection options
Ring material Number Size (NPT)
F1 316 SST 1 ¼–18 NPT
F2 316 SST 2 ¼–18 NPT
F3 Alloy C-276 1 ¼–18 NPT
F4 Alloy C-276 2 ¼–18 NPT
F7 316 SST 1 ½–14 NPT
F8 316 SST 2 ½–14 NPT
F9 Alloy C-276 1 ½–14 NPT
F0 Alloy C-276 2 ½–14 NPT
Lower housing intermediate gasket material
S0 No gasket for lower housing
SY(25) Thermo-Tork® TN-9000
NACE certificate(26)
Q15 Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials
Q25 Certificate of compliance to NACE MR0103 for wetted materials
HART Revision configuration(1) (requires HART protocol output code A)
HR5 Configured for HART Revision 5
HR7 Configured for HART Revision 7
Typical model number: 3051L 2 A A0 D 21 A A F1

Good Service in WTL :
> We offer high quality, fast delivery, competitive price for Mitsubishi Servo Motor and Servo Drive.
> Please send your RFQ to get the latest price.
> Normally, we will ship the items in 1-2 weeks after receive the payment.
> We can ship to you by UPS/DHL//EMS/Fedex. Please contact us and we will use your preferred ways.
> We have a large stock and the prices are variable, so sometimes the prices we post are not accurate.

If needed, please contact us for specific prices.

OUR MAIN BRAND:

3051L2AA2AD21AADFE5 Level Transmitter Rosemount 3051 4 To 20mA

China 3051L2AA2AD21AADFE5 Level Transmitter Rosemount 3051 4 To 20mA supplier

3051L2AA2AD21AADFE5 Level Transmitter Rosemount 3051 4 To 20mA

Inquiry Cart 0