Inline Load Cell 10t 20ton Compression And Traction Load Cell 50 ton 100t 200t

Brand Name:Forsentek
Model Number:FLB
Minimum Order Quantity:1pc
Delivery Time:3~25 working days
Payment Terms:T/T,Western Union or Paypal
Place of Origin:China
Contact Now

Add to Cart

Site Member
Location: Shenzhen Guangdong China
Address: 2# Jinlong Rd. Baolong Industrial Zone, Longgang Dist. Shenzhen China 518000
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Inline Load Cell 10t 20ton Compression And Traction Load Cell 50 ton 100t 200t

Threaded Inline Type Rod End Load Cell FLB is made of high stiffness alloy steel based on strain gauge technology intended for both traction and compression force measurement. In-line load cell FLB is designed to be mounted inline to the load axis with rugged structure for industrial applications. The Tension Compression Sensor FLB can be easily mounted to existing system through the threaded rods located on both sides of the transducer, these metric threads can also be used to mount attachments, such as female eye bolt, bolt adapter and so on to fit different usage requirements. Tension Compression Sensor FLB offers 0-10ton / 0-20ton / 0-30ton / 0-50ton / 0-70ton / 0-100ton / 0-200ton / 0-300ton eight rated measuring ranges, each sensor is integrated with a 6-meter-long 4-core shielded cable. Inline Type Force Transducer FLB is normally used for press-in force measurement, cylinder thrust measurement, hydraulic press, material testing machines, general process control and so on.

Ordering codeMeasuring RangeForce direction
FLH-100kN0-100kN / 0-10 ton

Traction

and

Compression

FLH-200kN0-200kN / 0-20 ton
FLH-300kN0-300kN / 0-30 ton
FLH-500kN0-500kN / 0-50 ton
FLH-700kN0-700kN / 0-70 ton
FLH-1000kN0-1000kN / 0-100 ton
FLH-2000kN0-2000kN / 0-200 ton
FLH-3000kN0-3000kN / 0-300 ton


Specifications

Rated capacity

100kN / 10ton / 22.4klb

200kN / 20ton / 45klb

300kN / 30ton / 67klbf

500kN / 50ton / 112klbs

700kN / 70ton / 157klbf

1000kN / 100ton / 225klb

2000kN / 200ton / 450klb

3000kN / 300ton / 674klb

Rated output2.0mV/V
Excitation5-15V
Zero balance±0.05mV/V
Nonlinearity

±0.1% of R.O.

>1000kN: ±0.3% of R.O.

Hysteresis

±0.1% of R.O.

>1000kN: ±0.3% of R.O.

Nonrepeatability

±0.1% of R.O.

>1000kN: ±0.2% of R.O.

Creep(5min)±0.05% of R.O.
Safe overload120% of F.S.
Ultimate overload150% of F.S.
Compensated temperature-10...+40oC
Operating temperature-20...+60oC
Temperature shift zero±0.05% R.O./10oC
Temperature shift span±0.05% R.O./10oC
Input resistance380±30 ohms
Output resistance350±5 ohms
Insulation resistance>2000M ohms
Ingress protection

IP62

Material of elementAlloy steel
CableØ5.8*6000mm 4-core shielded
Wiring codeRed--Excitation+ Black--Excitation-
Green--Signal+ White--Signal-

A Force Sensor is a transducer that converts mechanical load into mV signal proportional to the applied force.The acting force causes deformation of the measuring element,the bonded strain gage deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally,thus the load/force can be measured by measuring the output signal from the transducer.

Load cell output: = (Power supply * Rated output) * Load / Capacity

Rated output of Rod End Force Sensor FLB is around 2.0mV/V.

Power supply of Compression/Tension Force Transducer FLB is normally within 5-15V.

Load / Capacity is within 0-1.

So the output range of Threaded In-line Load Cell FLB is normally within -30mV...+30mV for bidirectional force measurement.

Example: Traction and compression load cell FLB-500kN with 2.0mV/V sensitivity powered by 10V DC ,the output range is -20mV...+20mV.

A signal conditioner can be used with force transducer FLB to deliver -5~5V, 0-10V or 4-20mA output.

Example: Push/pull load cell FLB-100kN working with -10-10V amplifier,the Force-Voltage relationship will be 0-100kN compression load VS 0-10V output, 0-100kN traction load VS 0-(-10V) output, which is linear regardless of the measurement error. When you get 5V output, it means the current load is 50kN compression force, when you get -1V output, it means the current load is 10kN traction load.

Inline Load Cell 10t 20ton Compression And Traction Load Cell 50 ton 100t 200t

Click here to download datasheet

China Inline Load Cell 10t 20ton Compression And Traction Load Cell 50 ton 100t 200t supplier

Inline Load Cell 10t 20ton Compression And Traction Load Cell 50 ton 100t 200t

Inquiry Cart 0