Low Range Single Point Load Cell 30g Low Capacity Single Point Weight Sensor 30g

Low Capacity Single Point Load Cell FMJ-30g is made of aluminum based on strain gauge technology with 30g rated capacity, high accuracy with 0.05% non-linearity of the full scale. You may find low range single point load cell FMJ-30g suitable for electronic balance, jewelry scales and other industrial weighing applications.

Dimensions

Specifications

Capacity

30g

Rated output0.5±0.15mV/V
Excitation3-10V
Zero balance±0.1mV/V
Nonlinearity±0.05% R.O.
Hysteresis±0.05% R.O.
Nonrepeatability±0.05% R.O.
Creep(2min)±0.05% R.O.
Safe overload150% F.S.
Ultimate overload200% F.S.
Compensated temperature-10...+40oC
Operating temperature-20...+60oC
Temperature shift zero±0.1% R.O./oC
Temperature shift span±0.05% R.O./10oC
Input resistance1150±100 ohms
Output resistance1050±100 ohms
Insulation resistance>2000M ohms
Ingress protectionIP50
Material of elementAluminum alloy
CableAWG32*90(Longer cable available)
Wiring code

Red--Excitation+ Black--Excitation-

Green--Signal+ White--Signal-


A load cell is used to determine mass: The weight force exerted by the sample is converted into an electrical signal by the load cell. Load cells are therefore the most important components of an electronic scale. One of the most widely used technologies is based on strain gauge technology: an analog load cell consists of a measuring element (so-called spring body) made of steel or aluminum, on which strain gauges (Wheatstone bridge) are mounted, strain gauges are electrical resistors that change their resistance while loaded, these resistance change leads to the change of output signal, the load/weight then can be measured and evaluated by measuring the output signal from the wheatstone bridge. Overloading is the most common cause of loadcell failure, a load sensor is just like a spring in certain aspects, which will be damaged if overstretched or overloaded. A machanical stop can be used to protect the sensor from excessive deformation. The deformation gap can be determined by loading the sensor with rated capacity, then adjust the meachnical stop to reach the bottom of the transducer. In most cases, the load cell will be used to measure load at 40-80% of the full capacity, thus the deformation gap can be adjusted using reference load a bit higher than the target load to be measured instead of the rated capacity.