Customized Medical Equipment Batteries With SMBus Communication

Brand Name:Topband
Certification:MSDS, ISO9001, ISO14001
Model Number:TB1250F-P105A
Minimum Order Quantity:100pcs
Delivery Time:2~4weeks for samples; 4~6weeks for mass production
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Active Member
Address: Topband Industry Park,Tangtou Town,Bao'an District,Sheznzhen,China
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

Customized Medical Equipment Batteries With SMBus Communication


  • long life cycle( 2000cycles @ 100%DOD)
  • super quick charge/discharge performance
  • safe pressure valve design ( no explosion, no fire)
  • high energy density
  • low self-discharge( <3% per month)
  • 1/3 weight & 1/2 volume of lead acid battery
  • eco-friendly
  • high consistency
  • no memory effect
  • easily replace lead acid battery

1. Battery Pack Brief Introduction

This specification applies to the TB1250F-P105A battery manufactured by Shenzhen Topband Battery Co., Ltd, Describes the type and size, performance, technical characteristics, warning and caution of the rechargeable cell. It is strictly prohibited any series or parallel between the battery pack. If the user needs to support the series parallel use, please contact us.


11 Battery Type

LiFePO4 (LFP)

12 Reference Standard

13 Product SPEC

12V/50Ah 4S2P


14 Cell Brand and Model

TB-027070180C-Fe-25Ah


15 Period of Warranty

Period of Warranty reference to the contract


16 Battery Specification Amendment

If the raw materials, production processing, production system or battery usage environments & other conditions need to be change, the amendment side needs provide the written advice to the other side, only the both sides come to an end, the amendment will be effective.


2. Battery Pack Basic Features

NO.ItemsCharacteristicsTesting Methods
1Nominal Voltage12.8VFollow GB/T18287-2013>
2Nominal Capacity50AhFollow
3Minimum Capacity47.5AhFollow
4Battery internal ImpedanceInternal Impedance≤50mRInternal Impedance Testing Machine(1kHz )
5Shipment Voltage12.8~13.6VMulti-meter
6DimensionLength187*166*117mm(MAX)Vernier caliper
Width
Height
gross weight5.8±0.3kgelectronic scale
7Working TemperatureCharge0~45℃,45~85%RHTemperature & Humidity Instruments
Discharge-20~55℃,45~85%RH
8Storage Temperature & Humidity RangeShort: above one month-20~+55℃,45~85%RHTemperature & Humidity Instruments
Medium: above three months0~+45℃,45~85%RH
Long:above one year+5~+30℃,45~85%RH
9Allowed maximum continuous charge current30AMulti-meter
10Allowed maximum continuous discharge current30A
11Allowed maximum reverse charge voltageNO Allowed/
12Allowed maximum charge voltage14.6±0.1VMulti-meter
13Discharge cut-off voltage10VMulti-meter

3. Battery Pack Electrical Characteristics

3.1 Testing Conditions (Unless Specially Requirements)

Temperature:20±5℃ Related Humidity: 45~75%

Atmosphere Pressure: 86~106kPa

The testing items under the Shipment Voltage(12.813.6V)

3.2 Battery Pack Electrical Characteristics

No.ItemsStandardsTesting Methods
1Internal ImpedanceImpedance ≤50mRUnder 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test
2Nominal Capacity50AhRest for 0.5~1 hour after fully charge, Using electrical loader to connect with the battery output port, and discharge with constant current 0.2C till it can’t discharge. Do the cycle three times, if there is one time that the discharge time is equal or more than 285minute , you can stop.
3Short circuit protectionNo load ability after short-circuit .comeback capability of loading after remove the lead away,Short the pack with the lead (<50mR). If remove the lead away, connect the electronic loader with P+, P- of protection board again, so load ability comes back.
4Allowed Maximum continuous charge Current30Acharging with this current for more than 0.5h and the added temperature of battery pack less than 20℃.
5Allowed Maximum continuous discharge Current30ADischarging with this current for more than 0.5h and the added temperature of battery pack less than 20℃.
6Over Current Protection120~150AUsing electron load connect with output side, discharge with 120A for about 2sec Discharge with 150A for less than 100 millisecond,

7the delay time of over current protection20~100msUsing electron load connect with output side, discharge with more than 150A and record the voltage wave of output side with oscillograph . Numerating the time of voltage from wave to zero for voltage
8cycle lifeDischarge Capacity ≥80%Discharge it with the current of 0.2C to the cut-off voltage, and store it for 15min.Charge a battery with the current of 0.2C, then keep the voltage and current constant and continue to charge it until completed . After storing the battery for 15min. The test is to be conducted as per the above cycles. The cycle should be 1000 times. At the 1001 times discharge capacity should not be less than ≥80% with 0.2C.
9Discharge Temperature CharacteristicsThe ratio between discharge capacity and charge capacity should be not less than the following valueAt 20±5℃ discharge the battery with the current of 0.2C to the cut-off voltage and record charge capacity. Store the battery at the following temperature for 2h and discharge the battery with 0.2C to the cut-off voltage.
Discharge CurrentDischarge Temperature
-20℃0℃25℃55℃
0.2C60%80%100%95%
10Charge Retentionremain capacity≥90%At 20±5℃ completely charge and store it for 28days,and then discharge it with 0.2C to the cut-off voltage. (We suggest charge the battery to 12.8~13.6V every three months)
11Over Discharge Protection furbishCharging With 0.2CCharge the battery with 0.2C for 5min and measure the output voltage (≥8V)of the battery pack. The battery should have load .

4. SMBus

The battery pack compatible with SBD ata v1.1 instructions. The host sends a corresponding instruction to the battery pack to receive the battery information.

In addition, the battery pack can convey the host for the radio alarm and charging information. The following chart is the summarizes for the SBD ata.


5. Battery Pack Reliability Test

5.1 Testing condition (Unless Special Requirements)

Temperature:20±5℃ Relative Humidity: 45~75%

Atmosphere Pressure: 86~106kPa

All testing under full capacity(Battery pack voltage13.2-13.6V)

5.2 Reliability Test

No.ItemsStandardsTesting Methods
1Vibration TestingThe appearance of battery should not leakage, break or explosionFix a charged battery on a vibrating table, vibrate it for 90 minutes in three mutually perpendicular directions at the 0.8mm resonance. The frequency is to be varied at the rate of 1hz/min between 10 and 55 hertz.
2High Temperature Discharge TestingThe battery should be no remarkable breakage, distortion. Discharge time should not less than 255minsPlace a full charged battery under the environments of 55℃ for 2 hours. Discharge it at the current of 0.2C to the cut-off voltage. Then keep it at 20℃±5℃ for 2 hours.
3Low Temperature Discharge TestingThe battery should be no remarkable breakage, distortion. Discharge time should not less than 180 minutePlace a full charged battery under the environments of -20℃ for 15-24 hours. Discharge it at the current of 0.2C to the cut-off voltage. Then keep it at 20℃±5℃ for 2 hours.
4Constant Humidity & Temperature TestingThe battery should be no remarkable breakage, distortion. Discharge time should not less than180minsPlace a full charged battery under the environments of 40℃ and 90% - 95%RH for 48 hours. And keep it in the room temperature for 2 hours. Then discharge it at the current of 0.2C to the cut-off voltage.
5High & Low Temperature StorageThe battery should be no remarkable breakage, distortion. And charge/discharge normallyPlace a full charged battery in a oven with 55±2℃ for2 hours, then keep it under 20±5℃ for 4hrs, then place it in a oven with -20±2℃ for 2 hours, then keep for 4 hours under 20±5℃, cycle as high temperature-normal temperature-low temperature-normal temperature-high temperature for 10 times

6. BATTERY PACK SAFETY TEST

6.1 Testing condition (Unless Special Requirements)

Temperature:20±5℃ Relative Humidity: 45~75%

Atmosphere Pressure: 86~106kPa

All testing under full capacity(Battery pack voltage13.2-13.6V)

6.2 Battery Pack Safety Test

No.ItemsStandardsTesting Methods
1Short-CircuitThe battery should be no remarkable breakage, distortion. And charge normally.Use a resistor with less than 0.05Ω to make the battery short circuit for 1 hour. The appearance and characteristics are normal.
2Over Discharge Protection TestThe battery should be no remarkable breakage, distortion. Appearance and charge are normal.Discharge the battery at the rate of 0.2C with the load of 30Ω for 24h . Charging for 10sec with specified adapter , and check the voltage(8V)
3Impact TestThe battery should be no explosion or catch firePlace a full charged battery on a flat and put a stainless steel stick (Diamond 7.9mm) in the middle of the battery upright . Beat the steel stick with 9.1Kg

7. Pack diagram

Connection Ports Instruction:

1. Pack Output Positive and Negative Electrode: The same port for charge and discharge, Anderson line for

30A output current, red for P+ and black for P- ;

2. Communication Interface Type: The following figure Interface (See graph below): The Communication need 3

Pin wire: GND/ CLK/ DATA the Sequence of the 3 lines as follow:


China Customized Medical Equipment Batteries With SMBus Communication supplier

Customized Medical Equipment Batteries With SMBus Communication

Inquiry Cart 0