Auto Lab Analyzer Equipment Chemiluminescence Immunoassav Analyzer


Advantages of Reagent System


Micro superparamagnetic beads, quick response and complete reaction.

New APLS substrate,and the time to reach platform stage can be shortened to less than 20s, which can greatly shorten the test time.

Complete test menu which can be applied in the detections of thyroid function, fertility, GlycoMetabolism, bone metabolism, tumor markers, Hepatic fibrosis, Prenatal screening, cardiac markers, etc. The menu will be expanded.

Six-point / two-point calibration.


Reagent Loading


10 kinds of reagents can be loaded at the same time, and continuous loading can be implemented without stopping the test.

Barcode scanning to load the reagent kits.

Automatic continuous magnetic bead mixing system.


Sample Loading


78 pcs of samples can be loaded at the same time, and continuous loading can be without stopping the test process.

Networking with LIS connection.

Compatible with primary collection tubes(75mm/100mm).


Other Advantages


Disposable tip sampling system to avoid cross-contamination

24-hour standby,samples can be detected at any time

Batch processing, STAT

Liquid level detection , reagent volume monitoring, failure alarm

Automatic dilution, and the dilution ratio can be set randomly.

Incubation conditions:37℃ stable.


Main Parameters


Principle: CLIA (Magnetic Microbeads Separation)

Throughput: 60T/H

Time to first result: < 15 min

Sample tube size: 75mny100mm

Auto re-test: available

Internal master curve, 2-point/6-point calibration

Barcode scanning to identify and locate reagent/sample


Advanced Detection Principle


Magnetic solid phase separation CLIA-Combination of magnetic solid phase technology and Chemiluminescence technology

Wider linear range, higher sensitivety and test speed, fully meet the clinical need


Low Failure Rate Design


Tip size same as the reaction tube size

Same mechanical unit shared, lower tailute rate


Intelligent Sample/reagent Carousel


Intelligent allocation for the reagent/sample position according to the customer's requirement


Streamlined Operating System


User-friendly interface, simple and convenient

Intelligent Calibration&QC

LIS connection

Data editing, storage, query and printing


Intelligent Sample/reagent Carousel


Sample positions: 5-75, intelligent allocation,continuous loading

Reagent positions: 1-15, intelligent allocation,extendable

Barcode scanning to identify and locate sample/reagent, avoid human error

Reagent storage and expiration reminder, avoid waste

Auto mixing for the magnetic beads reagent

Refrigerated function, ensure best condition of sample/reagent

STAT


4-hour Unattended Tip/Reaction tubes Loading Area


Adopt TIP for sampling to avoid cross-contamination

Tip size same as the reaction tube size Same mechanical unit shared, lower failure rate

Reaction tubes: 288pcs, extendable

Tip: 384pcs, extendable



Precise Temp-control Incubation Tray/Complete Separation Cleaning Tray


Incubation tray: 37±0.1℃, ensure complete reaction

Cleaning tray: 4-step auto cleaning, completely separate the solid phase from the free phase

Sidewall opening of the probe ensures the solid phase completely separate from the free phase



Innovative FITC- Separation Technology by Magnetic Beads Binding with Anti- FITC


Tublar chemiluminescence technology, Flexible

Antibody and antigen reacts in liquid status, full time and complete reaction

Only 5 minutes for magnetic beads involved in the reaction, avoid the non-specific adsorption

Superparamagnetic beads, solid phase easily separates from free phase

Strict process control, small intra-batch differences


Innovative AP-APLS Chemiluminescence Technology


High sensitivity, no less than 10-21 per unit

Innovative APLS substrate, reach plateau period fast

Long plateau period, stable signal, easy detection

Monocomponent non-oxidizing substrate,easy operation, long validity