Multifunctional Operating Room Equipment Anesthesia Machine With 2 Vaporizers

Brand Name:MeCan
Certification:ISO
Model Number:MC-01-B
Minimum Order Quantity:1 set
Delivery Time:3-15 working dates
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Guangzhou Guangdong China
Address: RM718, EASTERN BUILDING, XIAOBEI, YUEXIU, GUANGZHOU, CHINA.
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Multifunctional Operating Room Equipment Anesthesia Machine With 2 Vaporizers


Model : MC-01-B


Specification of Anesthesia Device:


Prospective service and support


This MC-01-B Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient’s respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.


TECHNIQUES SPECIFICATIONS
Physical specifications
Screen:5.4'' Display Screen
SuitableAdult & Child
Mode:pneumatically powered and electrically controlled system
Working Mode:Closed; Semi-Closed; Semi-Open
CircuitBreathing circuit integrated standards
Tube:4Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min
Trolley:Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
Drawer unitTwo drawer totally extractable
Technical Specifications:
Gas requirement:Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa.
safety valve<12.5 kPa
Respiratory Rate1~99bpm
Flow meterO2:0.1~10L/Min, N2O:0.1~10L/Min
oxygen concentration in the mixed gas N2O/O2> 21%
Oxygen Flush:25~75 L/min
modes of ventilationA/C, IPPV, SIPPV, IMV, SIMV, MANUAL
I/E Ratio:4:1 ~ 1:10, Has the inverse ratio ventilation
Tidal Volume0~1500ML
Inspiratory trigger pressure-0.1kPa~1.0kPa
Inspiratory Plateau:0~1s
O2 Concentration:21%~100%
Maximum safety pressure:≤ 12.5 kPa
Pressure limit range:0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual and with yellow and red color indicatingLower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa
±0.2 kPa
Tidal volume alarm: Audible and visual and with yellow and red color indicatingupper alarm: 50 to 2000ml, lower alarm: 0~1800ml
Power Supply AlarmAc/dc power supply are after failing to send out alarm immediately
Alarm Time: keep >120s
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
Operating conditions
Ambient temperature:10 ~ 40oC
Relative humidity:no higher than 80 %
Atmospheric pressure:860 hPa ~ 1060 hPa
Power requirement:100-120 Vac, 50/60 Hz;
Air source requirement:Medical oxygen and laughing gas with a rated pressure ranging from 0.3 to 0.5MPa.
Attention: the AC power supply used for the anesthesia machine must be well grounded.
Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System.
Storage
Ambient temperature:-15oC ~ +50oC
Relative humidity:no higher than 95 %
Atmospheric pressure:86 kPa ~ 106 kPa.
 It should be stored in a room without corrosive gas and well ventilated
Package
packaging boxcomply with the requirement of GB/T 15464
 Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
 Moisture protection and rain protection to ensure that product is protected from natural damage.
Safty & Alarm
Oxygen AlarmIt alarms when the oxygen supply from pipe or cylinders lower than 0.2MPa
Ventilation Volume AlarmLower: 0~12L/Min; Up: 18L/ Min
Power AlarmIt Alrmas while AC and DC supply failure ; Keep alraming time: >120s
Air Tract Pressure AlarmLower: 0.2kPa ~5.0 kPa; Up: 0.3kPa ~ 6.0kPa

China Multifunctional Operating Room Equipment Anesthesia Machine With 2 Vaporizers supplier

Multifunctional Operating Room Equipment Anesthesia Machine With 2 Vaporizers

Inquiry Cart 0