Large Autoclave Steam Sterilizer Double Doors Pulse Vacuum Up To 3000 L

Brand Name:MeCan
Certification:ISO
Model Number:MC -0.25
Minimum Order Quantity:1 set
Delivery Time:10-15 working dates
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Guangzhou Guangdong China
Address: RM718, EASTERN BUILDING, XIAOBEI, YUEXIU, GUANGZHOU, CHINA.
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Large Autoclave Machine Double Doors Pulse Vacuum up to 3000L


Model : MC -0.25


Parameter
Air removalPulse Vacuum (can be set 3-9times)
DryingVacuum drying
Stand by or notyes
The material of the shellFully stainless steel
Adding water automaticallystandard
Exhausting water automaticallystandard
Door lockFully automatically, double door interlock
Outer size(L*W*H)1100*1300*1700mm
Minimum installation room(L*W*H)2200*2300*2200mm
Door StructureDouble door motorized door
Sterilizing room288L±5%
Sterilizing chamber shape

Horizontal type, 304 type, welding,


mechanical polishing,0.4

Chamber size (L*W*H)800*600*600mm
Net.Weight900kg
Gross.Weight1050kg
Package size(L*W*H)1300*1450*2100mm
Water tank capacity58L
Average water consuming for each cycle40KG
Maximum temperature of the water tank136℃
Design pressure0.245Mpa
Design temperature139℃


Working power supplyAC380V,50HZ,
Power consumption≤28KW
Heat average≤+2℃
Steam pressure0.3-0.5Mpa
Water resource pressure0.1-0.3Mpa
Compressed air0.5-0.8Mpa
Power fluctuate±10%
Control system

Main controller PLC,microcomputer touch screen,printer and the other control

elements

Display

7” colorful


SIEMENS

screen,touchablefrom
With printeryes
TRAYS (standard allocation)2
Tray size(L*W*H)550*760*50mm
Sterilizing cycle

5 fixed sterilizing cycles+2 fixed testing cycles+1 fixed debug cycle+1 fixed fluid

cycle+ free setting cycle

Sterilizing items

Solid,fluid(heat resistance and placed into


un sealed fluid)

Sterilizing temperature(selectable)From 105℃ to 134℃


PROCESS


The regular setting of the device is divide into solid and fluid for the users’ choose, and also with the manual procedure for operators.


  • The chart for the sterilization to the solid objects:Applied to the instruments, dressings, utensils and other items.




  • The introduction for the sterilization to the fluid, applied to the fluid placed into the non-sealed media which can not bear the high heat and vacuum process.

  • Manual procedures: According to the special needs of the sterilized items and the different abnormal operating conditions, the users can set the
  • parameters under this program to call the device all reasonable combination features.

The chart for the time of each cycle: (Time: min)

Sterilizing itemsPre-h eatingvacuumHeat mins

Sterilizi


ng

Dryin g timeCycl e timeRemard
timesmins

Temp

eratur e

Ti me

Naked


instrument

53105134℃3023Without drying

Naked


instrument

53105134℃3225

drying , load <


30KG

packaged


instrument

53105134℃

3.


5

1538.5

drying , load <


30KG

Packaged


instrument

53105134℃152055

drying , load <


30KG

Heat sensitive items and

textile

53105121℃202060

drying , load <


10KG

fluid50010121℃30Exhau50heat resistance or

sting


time 5

unsealed fluid
BD test53105134℃

3.


5

529.5

Testing procedure(in accordance with the requirement of

the testing bad)

Vacuum test

Sucking the air till the vacuum rate

reach -86Kpa

In the following 10 mins, the decrease allowable pressure each min is ≤ 0.13KPA, or the total decrease

pressure for 10 min is ≤1.3KPA.

Debug cycleFor the use the the factory inspection and repairing
Free cycle

the sterilizing parameter can be set freely in accordance with different


requirement .