Standard Bunched Cable Flammability Test Chamber 1M / S Speed 0.1Mpa Gas Pressure

Brand Name:Kinte
Certification:Certificate of conformity of quality management system certification
Model Number:Wh-8820f-1685
Minimum Order Quantity:1 set
Delivery Time:Customized
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Active Member
Location: Guangzhou Guangdong China
Address: No.16 Yufeng Road, Shiling Town, Huadu District, Guangzhou City, Guangdong Province
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Standard Bunched Cable Flammability Test Chamber 1M / S Speed 0.1Mpa Gas Pressure​




Scope: for bundled cables under the conditions specified in the ability to inhibit the spread of


flame, and its use of the cable: that is, power, communications and other unrelated.



The main components 1, the ignition control system 2, the collection tower and smoke device 3,


gas flow control system 4, smoke concentration measurement system 5, temperature control


system 6, flame control system data acquisition: 1) flow measurement 2) temperature


Measurement 3) speed measurement 4) smoke measurement and other data collection



Main Specifications


1, the wall (concrete brick wall 1698kg / m3), the inner surface of the black tiles, the building can


withstand high temperatures and flames burning.


2, the door: 0.9 × 2m (W × H) is not through the steel frame, tempered glass.


3, the thermal conductivity for the interior is 37.8 ° C when the outside temperature is 23.9 ° C.


4, smoke collection tower inclination of 40 degrees angle, the top of the cube is 914mm. The filter


is 610 sides long.


5, observation window length is 457 ± 25 mm, three sides (except the door side) to the ground


below the distance of 1295 ± 25 mm, the right to the wall distance 1143 ± 25 mm


6,Air inlet: 559 × 343mm (± 6mm), 914 × 305mm (± 6mm), 2438 (± 25mm) × 343mm (± 6mm)


7, exhaust pipe 406mm diameter, horizontal installed in the collection tower on the right side of


the cube


8, anemometer measurement area ground fire mouth base up 1.5m, the base is 305 × 76 ×


152mm


9, ladder height 2400mm, cross-section of 305 × 25 × 25 mm (L × W × H) Square, the distance


between the two cross-299 mm


10, the fire mouth flat length 341 mm width 30 mm on the 242 fire eyes, fire eyes long 257 mm,


the distance between the two horizontal fire eyes 3.2 mm, the vertical distance between two fire


eyes 2 mm, the distance between the three fire 5 mm


11, the indoor wind speed ≤ 1m / s speed


12, the gas flow 13.2L / M, gas pressure 0.1Mpa


13, 2438mm × 2438mm × 3353mm (test requirements: 14.5m ≤ brick wall internal area ≤ 36m)


China Standard Bunched Cable Flammability Test Chamber 1M / S Speed 0.1Mpa Gas Pressure supplier

Standard Bunched Cable Flammability Test Chamber 1M / S Speed 0.1Mpa Gas Pressure

Inquiry Cart 0