Features:The 24 digital inputs are arranged in three groups of 8
inputs each.The three groups E 62,00...E 62,07, E 62,08...E 62,15
and E 63,08...E 63,15 are electrically isolated from each
other.The inputs use 24V signals in positive logic (1 = +24 V).The
signal delay of the inputs is configurable to 7 ms (default) or 1
ms. The configuration is performed by setting certain bits in the
system constants KW 85,00 and KW 85,01 as follows:program is to be
aborted automatically, if an class 3 error occurs, see chapter B7
(Appendix), System constants.The connection to the CS31 system bus
is made by means of a 3-pole detachable terminal block. Please
observe:All of the AC31 devices, no matter whether they are master
or slave devices, are connected with twistedpair bus line as
follows: One core of the bus line is looped through via the BUS1
terminals of all devices to be connected to the CS31 system bus.
The other core of the bus line is looped through via the BUS2
terminals of all devices to be connected to the CS31 system bus.
Related Product Recommendation:
57310255A | 07KP90 | 07MK92 GATS110098R0161 |
DSRF160 | 07DC91 | 07MK92 GJR5253300R1161 |
57310255V | 07DC91 | 07NG61R1 GJV3074311R1 |
DSRF180A | 07MK92 | 07NG63R1 GJV3074313R1 |
57310255-AV | 07KT94 | 07PS62R2 GJV3074332R2 |
DSRF182 | 07KT94D | 07SK90R1 GJR5250200R0001 |
3BSE003571R1 | 07KT94K | 07ZE61R302 GJV3074321R302 |
48990001-LY | 07KT94i | 07ZE63R302 GJV3074323R302 |
DSSB110 | 07KT94 | 086363-002 OSPS2 |
48980001E | 07DC92 | 1700RZ10005C |
DSSB120 | 07DC92E | 1SAR330020R0000 |
48980002-A | 07DC92F | 200-CICN 200-CIE |
DSSB146 | 07DC92B | 2012AZ10101B |
48980001-AP/1 | 07AC91 | 35AE92A ER0002081060005 |
57120001-RB/1 | 07DI92 | 3ASC25H705/7 |
57120001-E/2 | 07KT95 | 3ASU21C110 LU6278 DCU30/7 |
DSTA133I | 07KT95 | 3AUA489002B4562 |
3BYN571200-E/00 | 07KT97F1 | 3BHE022291R0101 PCD230A |
CS1W-SCB21 | 07KT97C | 3BHE023784R2530 |
3G8B2-MA000 | 07KT97D | 3BHE024577R0101 PP C907 BE |
3G8B2-Z8040 | 07KT97B | 3BSE001245R1 3BSC640008R1 |
3G8B2-PS000 | DSPC172-2 | 3BSE003879R1 |
3G8B2-IP000 | 57360001-NB/1 | 3BSE011316R1 SDCS-PIN-52 |
3G8B2-AB001 | DSPC172H | 3HAC14550-4 |
3G8B2-CS000 | 57310001-MP/2 | 3HAC14551-2 |
3G8B2-NI021 | DSSR122 | 3HAC17484-8 |
DSQC 602 3HAC12816-1 | 48990001-NK | 3HAC17484-9 |
Product's Character:
If the basic unit 07 KT 94 is located at the beginning orat the end of the bus line, the bus terminating resistor(120 W) has to be connected additionally between theBUS1 and BUS2 terminals.calling up the menu item of ”Enable PLC mode” in the ABB programming and test system or performing a warm startperforming a cold start or power OFF/ON. Setting the cycle time see chapter B1 (Appendix), Processing times Addressing when remote modules are coReactions on errors of error class 3 The user can configure whether or not the user program is to be aborted automatically, if an class 3 error occurs, see chapter B7 (Appendix), System constants.Starting-up the AC31 system after power ON The user can enter a number of n remote modules in KW 00,09. The user program starts only, i.e. it handles process inputs and outputs only, if at least n remote modules have been adopted into the CS31 system bus cycle, see chapter B7 (Appendix), System constants
GJR5251063P1 Module Connector ABB
GJR5251200R0202 07AI90-S Analog Input Module ABB
GJR5251300R0101 07KT93 07 KT 93 Central Processing Unit - 90 Series
ABB
GJR5251300R0161 07KT93 07KT93 Central Unit - 90 Series ABB
GJR5251300R0171 07KT93,07KT93G 07KT93 Central Processing Unit ABB
GJR5251300R2171 07KT93-S 07 KT 93-S Central Processing Unit - 90
Series ABB
GJR5251400R0101 ICDG32L1 ICDG 32 L1 Input/Output Unit ABB
GJR5251400R0202 07DC91 Advant Controller 31 I/O Unit ABB
GJR5251400R3202 07DC91 Advant Controller 31 I/O Unit ABB
GJR5251500R101 07KP92 07 KP 92 Coupler Module ABB
GJR5251500R1101 07MK92 07KP92 AC31 S90 Communication Processor
(07MK92) ABB
GJR5251500R1161 07KP92E1 Communication Processor Module ABB
GJR5251600R0202 07AI91 Analog Input Unit ABB
GJR5251666R1001 ICDT08B5 Analog Input Module ABB
GJR5251700R0101 07KP94 Master Field Bus Communication Module ABB
GJR5252000R0101 07KP95 Coupler for Advant Fieldbus AF 100 Network
ABB
GJR5252100R0101 07KT94 Advant Controller 31 Basic Unit ABB
GJR5252100R0161 07KT94D, 07 KT 94K, 07 KT 94i Advant Controller 31
Basic Unit - 07KT94 ABB
GJR5252100R0201 07KT94 07KT94 CPU - Advant Controller 31 ABB
The use of the product:
1.open architecture to take advantage of traditional or renewable sources of energy!
2.365 days warranty for all the goods from us.
3.2000+ suppliers with us, we could help you to get any components
which is difficult to get.
1. Optimize plant operations
2.365 days warranty for all the goods from us.
3.2000+ suppliers with us, we could help you to get any components
which is difficult to get.
1.Q:Does Moore test the products before shipping ?
A:Yse , we have professional technology staff to test the goods
before
2. Q: Could Moore provide technology support?
A: We're in this field more than 12 years. If there's any problem,
please contact with us,we'll provide suggestion from our engineer
to help you solve problem.
3. Q: Does Moore keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in
warehouse, so could promise fast delivery.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )