Add to Cart
Woodward Parts 9905-003 Standard Test Method for Pour Point of Petroleum Products Ship to Worldwide
Product Description:
This test method is intended for use on any petroleum product. A procedure suitable for black specimens, cylinder stock, and nondistillate fuel oil is described in 8.8. A procedure for testing the fluidity of a residual fuel oil at a specified temperature is described in Appendix X1. 1.2 Several ASTM test methods offering alternative procedures for determining pour points using automatic apparatus are available. None of them share the same designation number as Test Method D 97. When an automatic instrument is used, the ASTM test method designation number specific to the technique shall be reported with the results. A procedure for testing the pour point of crude oils is described in Test Method D 5853.
Related Product Recommendation:
PCU1000 | 5463-581 | 8440-1750 | 128229-01 |
SST-DN3-PCI-2 | 5463-785 | 9905-003 | 128240-01 |
SST-DN3-PCI-2 | 5464-013 | 9907-175 | 129478-01 |
SST-DN3-PCU-1-E | 5464-210 | 9907-838 | 133396-01 |
SST-DN3-PCU-2-E | 5464-211 | EASYGEN-2500-5 | BS204 |
SST-DN4-102-2 | 5464-414 | SA1509-24 | BS205 |
SST-DN4-104-2 | 5464-544 | 5463-785 | BS206 |
SST-ESR2-CLX-RLL | 5466-353 | 5463-473 | BS207 |
SST-PB3-PCU-2 | 5466-355 | 5464-414 | CM202 |
SST-PB3-VME-1 | 5500-577 | 5464-544 | CNT204 |
5417-028 | 5501-380 | 5463-581 | DI232 |
5417-040 | 8271-467 | 5464-013 | DIO216 |
5417-175 | 8440-1750 | 5464-211 | DIO280 |
5437-672 | 9905-003 | 5417-028 | DIO32-C |
5441-693 | 9907-164 | 5501-380 | EM203 |
5453-203 | 9907-175 | 5417-175 | FM211 |
5461-644 | 9907-205 | 5417-040 | FS211/N |
5461-648 | 9907-838 | 5453-203 | MPC240 |
5461-650 | EASYGEN-2500-5 | 5437-672 | MX213 |
5461-655 | EASYGEN-3200-5 | 5441-693 | NT255 |
5462-408 | SA1509-24 | 5464-210 | PTAI216 |
5462-718 | 5462-948 | 5466-353 | RS204 |
5462-744 | 5462-408 | 5466-355 | SEM201 |
5462-757 | 5500-577 | 5461-655 | TLC532F |
5462-758B | 5462-916 | 5461-648 | 109548-01 |
5462-916 | 5462-758B | 5461-644 | 125720-01 |
5462-948 | 5461-650 | 5462-718 | 125760-01 |
5463-473 | 5462-744 | 5462-757 | 125768-01 |
Product's Character:
Pour points are expressed in integers that are positive or negative multiples of 3°C. Begin to examine the appearance of the specimen when the temperature of the specimen is 9°C above the expected pour point (estimated as a multiple of 3°C). At each test thermometer reading that is a multiple of 3°C below the starting temperature remove the test jar from the jacket. To remove condensed moisture that limits visibility wipe the surface with a clean cloth moistened in alcohol (ethanol or methanol). Tilt the jar just enough to ascertain whether there is a movement of the specimen in the test jar. The complete operation of removal, wiping, and replacement shall require not more than 3 s.
The use of the product:
1.Q:How about the payment terms ?
A:We frequently use T/T
2.Q:What about your shipping terms ?
A: We can ship by DHL,UPS,FEDEX,ARAMAX,TNT,and so on
3.Q:What about your lead time ?
A: We have many itmes in stock , 3-5 days you will receive it .
Email : sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )