Home /Power Cables /

Lb40 Aluminium Clad Steel Reinforced ACSR / AS Or ACSR / AW

Lb40 Aluminium Clad Steel Reinforced ACSR / AS Or ACSR / AW

Certification:ISO9001
Minimum Order Quantity:5tons
Place of Origin:Jiang su,China
Price:$1-1500/ton
Supply Ability:200tons/day
Packaging Details:standard export packing
Contact Now

Add to Cart

Verified Supplier
Location: Nanjing Jiangsu China
Address: Huarong Building, No.85 Guanjiaqiao, Gulou District, Nanjing, Jiangsu,P.R.China
Supplier`s last login times: within 21 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

(ACS) Aluminum Clad Steel Wires

Construction

Aluminum-clad steel wire, commonly abbreviated as AW or AS or AC, is an electrical conductor composed of an inner steel core and outer Aluminum cladding. Aluminum clad steel wire is a bimetallic in which aluminum covers on the steel core continuously and evenly.

Advantages

Aluminum-clad steel wire is superior to galvanized or aluminized steel in every way.

● Better corrosion resistance due to thick EC-grade aluminum covering

● Wider range of combinations of tensile strength and conductivity

● Lighter weight

● Excellent thermal stability

● Wider variety of products, with broad range of properties, quality, and size of steel wire and aluminum cladding.

● Compared with ordinary aluminum conductor steel reinforced, the conductor weight is 5% lighter, current-carrying capacity is 2-3% higher and power loss decreases 4-6%. Thus, the service life is long and it adds none erection cost.


Application

The aluminum clad steel wire is widely used in long-span transmission line, coastal areas and island as well as other hot and humid regions, salt fog regions and heavily polluted regions where the high corrosion resistance strand is needed.


It is used as the core of ACSR/AW, overhead ground conductor, extra high voltage overhead conductor, optical fiber composite overhead ground line, self-damping conductor line, bare overhead conductor, OPGW, ground wire, messenger wire, guy wire formed wire for protecting, terminating and splicing transmission and distribution lines, fence, barber wire and hardware, etc.


Standards

IEC 61232, ASTM B415, ASTM B502, AS 3607 and other International Standards.

However, can also supply a range of alternative designs with customized solutions to meet customer requirements.

Abbreviations

AW : Aluminum-clad steel wire as per ASTM B 502 Standard.

AS : Aluminum-clad steel wire as per IEC 61232 Standard.

AC : Aluminum-clad steel wire as per AS 3607 Standard.


Classification of Aluminum Clad Steel wire


Clas

14%

IACS

20.3%

IACS A

20.3%

IACS B

23%

IACS

27%

IACS

30%

IACS

35%

IACS

40%

IACS

Sectional Ratio of Al (%)

1325253037435262

Sectional Ratio of St (%)

8775757063574838

Weight Ratio of AL (%)

510.410.412.916.920.727.336.1

Weight Ratio of ST (%)

9589.689.687.183.179.372.763.9

Physical Constants


Class

14%

IACS

20.3%

IACS A

20.3%

IACS B

23%

IACS

27%

IACS

30%

IACS

35%

IACS

40%

IACS

Nominal Density at 20°C (g/cm3 )7.14

6.59


6.59

6.27


5.91


5.61


5.154.64
Final Modulus of Elasticity (Gpa)170

162


155

149


63

132


122


109
Coefficient of Linear Exp. (per °C)12 x 10-6

13 x 10-6


12.6 x 10-612.9x10-613.4 x 10-6

13.8 x10-6


14.5 x 10-6


15.5 x 10-6


Temperature coefficient (per °C)

0.0034


0.0036


0.0036


0.0036


0.0036

0.0038


0.0039


0.004


% Elongation at Fracture on 250mm

1.5


1.51.51.51.51.51.51.5
The design of an aluminum-clad steel wire with a specified conductivity is based on 61 % IACS of aluminum and 9 % IACS of steel. For example, the conductivity of 30% IACS is dealt with as follows: Designed conductivity: Aluminum (61 % IACS x 0.43) + Steel (9 % IACS x 0.57) = 31.36 % IACS. Then, taking into consideration allowances, minimum conductivity is specified as 30 % IACS (57.47 nΩm). When only the aluminum covering is taken into account as the conductive part in the conductor, the electrical resistance of aluminum-clad steel wires can be calculated by the cross-sectional area of aluminum as per above and the conductivity of 61 % IACS.

Specifications for Aluminum Clad Steel Wires (Before Stranding)


ClassType

Nominal Diameter

(mm)

Min Tensile Strength (MPa)


Min stress at 1 % elongation (MPa)


Max. Resistivity at Over 20°C (nΩ∙m)

14%1ACS


over

Upto & Including


A1.243.015901410123.5
3.03.515501380
3.54.7515201380
4.755.514001200
B2.14.017701550

20%1ACS


1.243.2513401200

84.80

3.253.4513101180
3.453.6512701140
3.653.9512501100
3.954.112101100
4.14.411801070
4.44.611401030
B4.64.7511001000
23%1ACS2.505.00122098074.96
27%1ACS2.505.00108080063.86
30%1ACS2.505.0088065057.47

35%1ACS


A2.505.00810590

49.26


B2.505.00880650

40%1ACS


A2.505.0068050043.10
B2.505.00750550

SINGLE WIRE AS PER ASTM B 415 STANDARD

Size

AWG


Diameter


Tensile

Strength


Cross

section


D C Resistance

at 20°C


Nominal

Weight


Minimum Thickness of Aluminum Cladding


in.mm

ksi


N/mm²


in²


mm²


Ω/km


lb/1000 ft


Kg/km


in


mm


( CONDUCTIVITY = 20.3 % IACS)
4.00.2045.18915510700.0327821.1494.01093.67139.370.010220.259
0.1884.77516011000.0277617.9094.73579.32118.020.009400.239
5.00.1824.62016511400.0259916.7665.05874.25110.490.009100.231
0.1734.39217011700.0234815.1485.59867.0999.820.008650.220

6.0


0.1624.11517512100.0206113.2986.37758.8987.630.008100.206
0.1553.93418012400.0188412.1586.97553.8480.120.007750.197
7.00.1443.66518512800.0163510.5518.03746.7369.530.007220.183
0.1373.47719013100.014729.4978.93042.0662.580.006850.174
8.00.1293.26419513400.012978.36710.13537.0655.140.006430.163
9.00.1142.90619513400.010286.63112.78729.3743.700.005720.145
10.00.1022.58819513400.008165.26116.11723.3034.670.00510.129
11.00.0912.30419513400.006464.16820.34318.4627.470.004540.115
12.00.0812.05219513400.005133.30825.63414.6521.800.004040.103
CONDUCTIVITY = 27 % IACS)
4.00.2045.1891258620.0327821.1493.01984.00124.990.014300.363
0.1884.7751067310.0277617.9093.20967.52100.470.014100.358
5.00.1824.6201107580.0259916.7663.42863.2194.060.013640.347
0.1734.3921147860.0234815.1483.79457.1184.980.012970.329
6.00.1624.1151147860.0206113.2984.32250.1474.600.012150.309
0.1553.9341188140.0188412.1584.72745.8468.210.011620.295
7.00.1443.6651228410.0163510.551 55.44739.7859.190.010820.275
0.1373.4771268690.014729.4976.05235.8053.280.010270.261
8.00.1293.26415610760.012978.3677.63233.2349.450.009000.228
9.00.1142.90615610760.010286.6319.62926.3439.190.008010.203
10.00.1022.58815610760.008165.26112.13620.9031.100.007130.181
11.00.0912.30415610760.006464.16815.31916.5624.640.006350.161
12.00.0812.05215610760.005133.30819.30313.1419.550.005660.144
( CONDUCTIVITY = 30 % IACS)

4.0

0.2045.1891027030.0327821.1492.71779.74118.650.015320.389
0.1884.7751067310.0277617.9093.20967.52100.470.014100.358
5.00.1824.6201107580.0259916.7663.42863.2194.060.013640.347
0.1734.3921147860.0234815.1483.79457.1184.980.012970.329
6.00.1624.1151147860.0206113.2984.32250.1474.600.012150.309
0.1553.9341188140.0188412.1584.72745.8468.210.011620.295
7.00.1443.6651228410.0163510.5515.44739.7859.190.010820.275
0.1373.4771268690.014729.4976.05235.8053.280.010270.261
8.00.1293.2641288830.012978.3676.86931.5446.940.009640.245
9.00.1142.9061288830.010286.6318.66625.0037.200.008580.218
10.00.1022.5881288830.008165.26110.92319.8429.520.007640.194
11.00.0912.3041288830.006464.16813.78715.7223.380.006800.173
12.00.0812.0521288830.005133.30817.37212.4718.560.006060.154
( CONDUCTIVITY = 40 % IACS)

4.0

0.2045.189805520.0327821.1492.03865.9598.130.025540.649
0.1884.775845790.0277617.9092.40755.8583.100.023500.597
5.00.1824.620886070.0259916.7662.57152.2877.790.022740.578
0.1734.392926340.0234815.1482.84547.2370.290.021610.549
6.00.1624.115966620.0206113.2983.24141.4761.700.020250.514
7.00.1443.665986760.0163510.5514.08532.9048.960.018040.458
0.1373.477986760.014729.4974.53929.6144.060.017110.435
8.00.1293.26499.56860.012978.3675.15226.0938.820.016060.408
9.00.1142.90699.56860.010286.6316.50020.6830.770.014300.363
10.00.1022.58899.56860.008165.2618.19216.4124.410.012740.324
11.00.0912.30499.56860.006464.16810.34013.0019.340.011340.288
12.00.0812.05299.56860.005133.30813.02910.3215.350.010100.257

SINGLE WIRE AS PER ASTM B 502 STANDARD


DiameterTensile StrengthStress at 1% ExtensionResistityDensity
in.mmksiN/mm2ksiN/mm2
0.0770 ~ 0.12891.956 ~ 3.27419513441751206

51.01


84.8


0.2381


6.59

0.1290 ~ 0.13693.275 ~ 3.47719013101701172
0.1370 ~ 0.14433.478 ~ 3.66518512751651137
0.1444 ~ 0.15493.666 ~ 3.93418012411601103
0.1550 ~ 0.16203.935 ~ 4.11517512061601103
0.1621 ~ 0.17294.116 ~ 4.39217011721551068
0.1730 ~ 0.18194.393 ~ 4.62016511371501034
0.1820 ~ 0.18804.621 ~ 4.77516011031451000
Coefficient of linear expansion Modulus of Elasticity

: 12.6 x 10-6 /°C

: 23500 Ksi (162000 MPa)

Temperature coefficient of Resistance: 0.0036/°C

Minimum Aluminum Thickness : 10% of nominal wire radius


SINGLE WIRE AS PER AS-3607 STANDARD

Diameter(mm)Tensile StrengthCross section

D.C Resistance

at 20℃


Nomial weight

Min.thickness of

Aluminum cladding

standardmax.min.N/mm2KNmm2

Ω/km


kg/kminmm
1.6001.6401.56013402.692.01142.2813.250.080
1.7501.7901.71013403.222.40535.3415.850.088
2.2502.2902.21013405.333.97621.3826.200.113
2.5002.5402.46013406.584.90917.3232.350.125
2.7502.7912.70913407.965.94014.3139.140.138
3.0003.0452.95513409.477.06912.0346.580.150
3.2503.2993.201134011.128.29610.2554.670.163
3.5003.5533.448131012.609.6218.8363.400.175
3.7503.8063.694127014.0311.0457.7072.780.188
Coefficient of linear expansion Modulus of Elasticity

: 12.9 x 10-6 /°C

: 23500 Ksi (162000 MPa)

Temperature coefficient of Resistance: 0.0036/°C

Minimum Aluminum Thickness : 10% of nominal wire radius


China Lb40 Aluminium Clad Steel Reinforced ACSR / AS Or ACSR / AW supplier

Lb40 Aluminium Clad Steel Reinforced ACSR / AS Or ACSR / AW

Inquiry Cart 0