IEC 60598-1-clause 4.12.5 glands testing , Test rods , Screws and connections and glands testing


Standard: IEC 60884-1 2013 clause 24.6, IEC 60598-1 clause 4.12.5


Application: This device is use for test the torque resistance strength of screwed gland of lamps and similar appliances.


Test sample: Screwed gland of lamps and similar appliances.


Feature: Floor type support, lifting weights mechanism drive turntable to achieve torque test.


Parameters:

  1. Cylindrical metal rod: Ф5, Ф7, Ф9, Ф10, Ф12, Ф14, Ф16, Ф18, Ф20, Ф22, Ф25, Ф30, Ф32, Ф40mm, one each, 14 pc in all
  2. Weights: 20N, 40N, 50N, 60N weight with hook, one each; 10N, 20N weight with hole, one each. Can meet the test requirements to most screwed glands.
  3. Diameter of the disc: 250mm(500mm disc for option, with less weights)
Diameter of test rod(mm)Metal glands(N.m)Glands of moulded material(N.m)
<76.252.5
7~146.253.75
14~207.55
>20107.5


TESTING AND MEASURING EQUIPMENT/ALLOWED SUBCONTRACTING IEC 60598-1:2014, A1:2017 Edition 8.1
Luminaires – Part 1: General requirements and tests

ClauseMeasurement/testingTesting / measuring equipment / material neededEquipment Classification
3.4Test of markingPiece of cloth / Water / Petroleum spiritR
4.4.4Lampholder pressure testTest caps / Pressure device / Torque driverR
4.4.5Voltage across lampholdersHigh voltage probe / OscilloscopeR
4.11.6Electro-mechanical contact systemLow voltage variable current power supply, voltmeter, high voltage transformerR
4.12.1 / 4.12.5Screws and connections (mechanical) and glands testingTest screwdriver or spanner / Test rodsR
4.13.1/4.13.4 4.13.6/4.21.4

Mechanical strength tests

Spring-operated impact test apparatus / Apparatus for ball impact tests Conditioning cabinet (e.g. freezer) / Angle measuring device / Weighting device / Tumbling barrel test equipment

R

4.14.1/4.14.2

4.14.3

Adjusting devices testingGlass test shelves / Weighting device / Test apparatus for adjustable devicesR
4.9.2/4.18.1Insulating linings and sleeves tests / Resistance to corrosionHeating cabinet, humidity cabinet, megaohmeter, high voltage transformerR

4.18.2/Annex FStress corrosionCloseable glass vessel / test solution / Heating cabinet / Facilities to wash samples after testR
4.20Rough service luminairesVibration test equipmentS
4.22Attachment to lampsWeighing deviceR

4.24/Annex P


Photobiological hazard: UV radiation, retinal blue light hazard

  • UV radiation test instruments / retinal blue light hazard test instruments (Equipment List of IEC/TR 62778
  • Goniophotometric measurement system

S


S

4.26Short circuit protection testTest chain / Weighting deviceR
4.28Fixing of thermal sensing controlsTemperature change test instruments in accordance to IEC 60068-2-14, test NaS
5.2.10.1Pull and torque tests on cord anchorageCord anchorage tests apparatus (pull and torque)R
5.3Internal wiring dimensionsMicrometer / Equipment for insulation thicknessR
5.4Test of conductors having a reduced cross-sectional areaThermometer / Thermocouples / Ammeter / Adjustable resistive loadR
7.2.3Earth continuity testEarthing test equipmentR

8.2.5

8.2.7

Protection against electric shock tests / Capacitor discharge

Standard test finger (IEC 60529) / Unjointed test finger

Voltmeter / oscilloscope

R


9.2.0Solid object proof luminaire testingIP 3X (2,5 mm) / IP 4X (1 mm) probesR
9.2.1 / 9.2.2Dust proof luminaire testsApparatus for proving protection against dustR
9.2.3,4,5,6,7, 8,9Water proof luminaires testingApparatus for protection against water testsR
9.3.1Humidity testsHumidity cabinetR
10.2.1Insulation resistance testsMegaohmmeterR
10.2.2Electric strength testsHigh voltage transformerR
10.3.1Leakage current testingLeakage current testerR

11.2.1Creepage distances and clearances measurementsDigital calliper (or equivalent) / OscilloscopeR
12.3.1Endurance testsThermal cabinet (35°C) / Endurance test equipment / Multimeter / WattmeterR

12.4.1


Thermal tests

Draught-proof enclosure (25°C) or alternative chamber/room / Thermometer / Thermocouples / Voltage stabilizer / Multimeter / Wattmeter

R

12.5.1e)

Annex C

Fig. C3


Abnormal operation testing


Test circuit for metal halide luminaires


R


12.7.2

Test for luminaires with temperature sensing controls internal/external to the ballast or transformerRelevant equipment of clauses 15.3 and 20.6, Equipment List of IEC 61558-1:2005

R

13.2.1Resistance to heat testHeating cabinet / Ball pressure test apparatus (see also CTL DSH 391 D)R
13.3.1Resistance to flame testNeedle flame test apparatusR
13.3.2Resistance to ignition testingGlow-wire test apparatusR
13.4.1Resistance to tracking testProof tracking test deviceR
14Screw terminalsTorque drivers, test cables, pull device, micrometer, timerR
15Screwless terminalsPull device, variable current source, voltmeter, heating cabinet, timer, test cablesR