Add to Cart
Operating Voltage 220v/50HZ ATS FPD-3FAN Hanging Ionizing air blower
It can provide a balanced ion flow; It can eliminate static or neutralize small concentrated targets or hard to reach areas .
Working principle:
ATS FPD-3FAN hanging Ionizer air blower Can produce a lot of air
with positive and negative Ion, the electric charges on the object
and fall, when the object surface is negatively charged, It will
attract positive charge in the air, when the object surface is
positively charged, it will attract negative charges in the air, so
that the electrostatic on the surface of the object and, to
eliminate the purpose of static electricity.
Product features:
* Suitable for big range to eliminate static electricity;
* Electrostatic quickly moving, convenient installation;
* With ion emitter cleaner;
* Inside there is fan and high voltage generator;
* Ion wind can be adjustable.
Applications:
1.Precision electronic products;
2.Electronic assembly line, the production of microelectronics, optoelectronics;
3.Pharmaceutical manufacturing assembly lines, printing, packaging;
4.Small part injection molding, shear plastic film, circle and film, as well as mold release etc..
Safety instructions
1 Must read the operating instructions before installation and
operation.
2 Before the operation Ion fan must be reliable grounding.
3 Protection grid plate entrance not to insert.
4 Flammable and explosive environment is not operable fan.
The ion fan hung on the proper height position, adjust the volume
size and thedirection of flow to the desired position, you can
start work.
Maintenance:
Emission head cleaning, ion balance adjustment, in addition to
staticcorrection, to ensure the normal work of ion fan.
1.Cleaning: clean emission point transmitter transmitter, sliding
or rotatingcleaning brush, until clean net ion emission tip, at
least once a week.
2.The air inlet, outlet air cleaner: entrance and ionized air
outlet should be cleanto prevent the obstruction of airflow, can
use soft brush to clean or compressed air cleaner.
3.Ion balance test: eliminate the time by measuring the
electrostatic electrostaticanalyzer
4.Electrostatic elimination time test: eliminate the time by
measuring theelectrostatic electrostatic analyzer
5.Ion fan, output design for ion amount is balanced, fixed. As may
be affected by the voltage fluctuation, ambient air humidity and
other factors will form the residual voltage offset ion balance.
Offset standards: OV ± 10V. If the static elimination time and
residual voltage has a large deviation, should be sent to the
factory for alignment.
Product warranty and service
1.warranty
All the product’s warranty period is one year, since the date of
sale quality problems caused due to product a year own part,
material and process problems, we will repair free of charge.
2.After the warranty period of service
Where the company sells after warranty period still will be
responsible to repair the product free in charge, in order to
protect the interests of customers.
3.If customers open and repair ion fan themselves, Our company won’t supply free warranty, according to the situation of discretion.
Specification:
Operating Voltage | 220v/50HZ |
Current Consumption | 0.62A |
Operating Temperature | 0---50℃ |
Size | 1100mm(L)*184mm(W)*125mm(H) |
Weight | 10kg |
Air Volume | 120---330CFM |
Offset voltage | 0v±10v |
Air Coverage | 110cm*120cm |
Test Results:
Testing Conditions | ||||
Testing Voltage:1KV to 100V Operating Voltage:110/220V Temperature:22℃ | ||||
Distance | 300mm | 600mm | 900mm | 1200mm |
Left300mm | 1.8s | 2.4s | 5.0s | 8.5s |
Center | 1.3s | 2.2s | 4.2s | 8.2s |
Right300mm | 1.7s | 2.5s | 4.7s | 8.4s |
Installation Method
1,Installation(As picture)