Data Concentrator Automatic Meter Reading System Three Phase Power Supply GPRS


DJGZ32-RDK15 intelligent data concentrator is one important part of AMI system. It connects with master station as a gateway for communication between the meters and the HES. It can perform task setting, data collection, data transmission and data storage, meter management, and task execution .


The upper communication between data concentrator and master station employs GPRS or RS232 technology; the Down link communication between data concentrator and the meters employs RS485/PLC communication.


Main Features

1) GPRS uplink with head-end server (HES)

2) Alternative com port :IR optical and RS485

3) On demand and scheduled meter readout

4) Remote load control overriding the consumers

5) Non-volatile memeory for data retention

6) IEC 62056-21 and DLMS/COSEM compliant

7) Automatic fault alarm to HES


Utility benefits

1) High capacity for a hub of up to 500 pcs sub-meters

2) Surge protection and low voltage operatable

3) Quick and easy to install

4) Low operational and maintenance cost

5) Remote tariff setting, time synchronization with meters

6) Long life time design with easy upgrade features


Specifications:


Electrical parameters:
Voltage
Nominal voltage Un220V/380V
Extended operating voltage range80%~115%Un
Limited voltage60%~130%Un
Frequency
Nominal frequency fn50Hz
tolerance-6%~2%
Current
Basic current(Ib)1.5(6)A
Maximum current(Imax)10A
Starting current(Ist)3mA
Active energy constant6400imp/kWh
Measurement Accuracy
Active energy1%
Reactive energy2%
Power Consumption
Power consumption in Voltage circuit<10W <8VA
Power consumption in current circuit<1VA
Temperature range
Working temperature-35℃ to+70℃
Limited working temperature-40℃ to+75℃
Insulation strength
AC Insulation strength4kV at 50Hz during 1min
Impulse voltage 1.2/50μs mains connections8kV
Electro Magnetic Compatibility
Electrostatic discharges
Contact discharge8kV
Air discharge16kV
Electromagnetic RF fields
27MHz to 500MHz typical10V/m
100kHz to 1GHz typical30V/m
Fast transient burst test4kV
Mechanical requirements
Meter shell Protection RateIP51