Function Introduction |
Conventional Function | offline operation; real time supervision; photo display; mass
storage; flexible user privilege setup; remote unlocking;
multi-user supervision; quick setting; convenient checking and
query; revisable and printable report form; report form;report can
be exported to excel file; card+password unlocking; alarm for long
time unclosing;alarm for invalid card swiping; first card
unlocking;alarm for illegal break in; unlocking at definite time;
e-map etc. |
Professional function | for professional users such as bank,cash house, telecom station,
power supply station,prison and plice station: interface locking;
intimidation alarm; integrated fire control;anti-passback and
anti-tail; interlocking;multi-card unlocking; emergency double
locking; in door population checking; unlocking based on internal
and external validation. |
all-in-one-card management system | nomal shift and multi-shifts time attendance management system;
fixed ration dining management system; meeting attendance
management system; online patrol management system and security
alarm management system. |
Parameter |
Communication | TCP/IP |
English Software supportable database: | Access and SQL |
Description | Control 2 doors, get in and out door by swiping card, or get in by
swiping card and get out door by button |
Power Supply | 12VDC 4-7A |
Power Consumption of Circuit Board | Less than 100mA |
Input Format of Reader | Wiegand 26 (All card reader with compatible protocol, such as
Motorola , EM , IC one etc) |
Quantity of Readers | 4pcs |
Door Controlled | 2 |
Door opening time extending setting | 1-600 seconds(adjustable) |
Max q ' ty of controller | N*256PCS |
| Remark: N denotes q ' ty of computer serial prot or q ' ty of
485hub port, support 256pcs ports |
Operation Temperature | minus 40°C-70°C |
Operation Humidity | 10-90 % RH , No Condensation |
Q ' ty of users | 20,000 Users |
Q ' ty of Event Buffers(offline) | 100,000 event buffers |
Power interruption protection measure | High Speed Memory, Records never lose |
Max Distance from Reader to Controller | 100m (suggestion distance 80m) |
Max Distance between Controllers | RS232: Communication Distance less than 13m, suggestion distance is
3m or less |
| RS485: bus line max length 1200m, suggestion length 1000m or less,
if expansion device added, the distance could be 3000m |
| TCP/IP: Depends on net coverage area |
Collocations | PCB board, case, power, power line, serial port communication line,
software, manual, certificate, key(2pcs), carton |
Alarm for long time door open, ilegal break in, intimidate | Yes |
Fire and alarm linkage | If no connection with the expansion board, only has software
interface alarm, and drive the computer speaker. If connected with
expansion board, is able to alarm by hardware, if connected with
strengthened expansion board, then is able to Security alarm |
Complsive open and close door at long time | Yes |