12v 24v Double door 600lb Signal monitored Electric Magnetic Lock , electromagnetic lock EM lock

Brand Name:Vians
Certification:CE/ROHS/FCC/MA
Model Number:VI-280BS
Minimum Order Quantity:10pcs
Delivery Time:7 working days after received your payment
Payment Terms:T/T or
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Floor 4,No.31,Yangmei Road,Yangmei Community,Bantian street,Longgang District,shenzhen,China
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

12v 24v Double door 600lb Signal monitored Electric Magnetic Lock , electromagnetic lock EM lock​


Product Overview


The design of magnetic locks(Electromagnetic lock) is the same as the electromagnet. By using the principle of electromagnetic, when current passes through the silicon steel sheet, magnetic locks will produce powerful suction, thereby helps to tightly absorb iron plate. Even small current will produce huge magnetic, which can effectively control the door.


Vians magnetic locks adopt international leading production equipment and packaging technology, which not only makes our locks' antioxidant capacity of the surface reach the international leading level, but also helps to increase the holding force (higher 20% than other manufacturers). Now our locks have been sold to more than 60 countries and regions around the world, they are widely used in the important places such as airports, subways, banks, prisons, intelligent buildings, intelligent community and so on, and become convenient, fast and intelligent tool for global users, gain good reputation from the customers.


Specification


Product ParameterParameter Description
Size500L*47W*26H(mm)
Armature Plate Dimension180Lx38Wx11H(mm)
Holding Force280kg(600Lbs*2)
Input Voltage12 or 24VDC
Current12V/500mA or 24V/250mA
SuitableWooden door , Glass door ,Metal door , Fireproof door
Surface Temp≤+20℃
Operating Temp-10~+55℃(14-131F)
Humidity0~90%(non-condensing)
Cover FinishAnodized aluminum
Lock FinishZinc
Armature Plate FinishZinc
Weight4.2KG

Product detail



Feature


◆ Collinear Load Test 280KG(600Lbs*2).

◆ Dual Voltage 12 or 24 VDC(optional).

◆ Built-in reverse current protection device (MOV).

◆ Anti residual magnetism design, anti-wear manufacturing materials.

◆ Shell is made of high-strength aluminum alloy, Anodized.

◆ Increase the holding Force, Dual Insulative Hosing.

◆ MA certified products of China / CE certification of EU.

◆ Complete electromagnetic suction working no mechanical failure.


Installation drawing

Product mounting bracket



Wiring


Trouble and Shooting


TroublesCauseShooting
Door cannot lock

1. Circuitry malfunction or low voltage.

2. The power supply wire is too thin and long to cause big decrease of voltage.

3. Power supply is broken to cause no voltage output.

4. The positive and negative wire of power supply is connected in reverse.

5. The electromagnetic lock no power input.

1. Check the connection, and measure the voltage to see if it is normal.

2. Modify or change the power supply wire into thicker one.

3. Check the power polarity and correct the connection.

4. Check to see if power supply or controller is correctly connected to NC.Make sure to see up the controller correctly.

No transform of indicator output with low holding force.

1. The mount plate and the electromagnetic lock face not in complete close.

2. The mount plate is fixed to tight, no room to move.

3. The electromagnetic lock and the mounting plate not at same level for case the door is deformed or moved.

4. The surface of mount plate or electromagnetic lock is not clear.

5. The power supply with lower power.

6. The power supply wire is too thin and long.

7. The electromagnetic lock is malfunction.


1. Check the face of mount plate or electromagnetic lock, if the face of plate is deformed to cause no complete close to the lock, please change the plate.

2. Check if the rubber gasket is put into the stick of plate, and adjusts the bolt of plates not too tight at least a little movable.

3. Adjust the mount plate and electromagnetic lock to be level at each other and close completely.

4. Clean the surface of lock and plate, if rusted to cause no working please change the part.

5. Use millimeter to check the voltage and current of electromagnetic lock to see if it is normal, or need repairing or changing power supply.

6. Change into high quality power supply wire, better no more the 20 meters.

7. Repair or change the electromagnetic lock.

Door cannot openThe power is not cut off

To check out the connection of power supply and controller, the electromagnetic lock is power-on locking power-off opening type. The lock can be open once power off.

Trade show



FAQ


Q:How do I pay for my purchase?
A: we accept the following payment methods: cridet card; moneybooker;T/T;.


Q:How much does it cost to ship to my country?
A:Please tell us your receive goods address, we will check the shipping cost for your reference


Q:Is there any tracking Number for my item?

A: Yes, we ship every order with their Tracking Number, and you can view the shipment staus on the corresponding website.


Q:Does this product come with retail package?

A: We have declared the packing detail on the description of each product, please check it, thank you!


Q:I am a reseller,I would like to buy many pieces of your item, what's the wholesale price?

A: Hi,thanks for your inquiry, if you would like to buy large quantity, please send email to us, we will give you the best price, thanks!

China 12v 24v Double door  600lb Signal monitored Electric Magnetic Lock , electromagnetic lock EM lock supplier

12v 24v Double door 600lb Signal monitored Electric Magnetic Lock , electromagnetic lock EM lock

Inquiry Cart 0