Home /Machine Tool Spindle /

1.1-1.5kw AC Single Phase Induction Motor 1400rpm MY90L-2 For General Driving

1.1-1.5kw AC Single Phase Induction Motor 1400rpm MY90L-2 For General Driving

Brand Name:ZOZHI
Certification:ISO
Model Number:MY90L-2
Minimum Order Quantity:1pc
Delivery Time:25 working days after received your payment
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Address: No.155 Shangcun Qingxiyang Industry Zone,Fuan city,Fujian,China
Supplier`s last login times: within 48 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

1.1-1.5kw AC Single Phase Induction Motor 1400rpm MY90L-2 For General Driving

Single Phase Induction Motor

What are the Applications of single-phase induction motors?


If you are finding the only answer for What are the applications of a single-phase induction motor?

Single-phase induction motors are used in smaller equipment requiring less horsepower (for example, one horsepower). Some of the examples of real-life are

  • Pumps
  • Compressors
  • Rice Machine
  • Mixers
  • Cutting Machine
  • High-speed vacuum cleaners
  • Drilling machines


MY Series Single-Phase Induction Motor Data

ModelOutputSpeedEff.P.F.Tstart/TnTmax/TnIst/In(A)
KWHP(V)(A)(r/min)(%)
MY631-20.180.252201.482800600.920.41.75
MY632-20.250.342201.962800630.920.41.77
MY711-20.370.52202.732800670.920.351.710
MY712-20.550.752203.882800700.920.351.715
MY801-20.7512205.152800720.920.331.720
MY802-21.11.52207.022800750.950.331.730
MY90S-21.522209.442800760.950.31.745
MY90L-22.2322013.672800770.950.31.765
MY631-40.120.162201.11400550.90.41.73.5
MY632-40.180.252201.621400560.90.41.75
MY711-40.250.342202.021400610.920.351.77
MY712-40.370.52202.951400620.920.351.710
MY801-40.550.752204.251400640.920.351.715
MY802-40.7512205.451400680.920.321.720
MY90S-41.11.52207.451400710.950.321.730
MY90L-41.522209.831400730.950.31.745

MY Series Single-Phase Induction Motor Condition

Ambient temperature: -15℃≤~≤40℃

Altitude: altitude does not exceed 1000m sea level

Rated voltage: ±5%

Insulation class: B

Protection class: IP55

Cooling method: IC411


Five things to keep you from burning your motor


1. Keep the motor clean. During the operation of the motor, there must be no dust, water stains, and debris within 3 meters of the air inlet. Otherwise, once it is sucked into the motor, it will form a short-circuit medium or damage the wire insulation, causing a short circuit between the boxes and burning the motor. Therefore, to ensure the safe operation of the motor, it is necessary to keep the motor and its surroundings clean so that the motor can maintain a safe and stable working state during long-term operation.
2. Ensure that the motor always works at rated current
Motor overload operation is mainly caused by too much drag load, low voltage, or mechanical jam caused by driving. If the overload time is too long, the motor will absorb a large amount of active power from the grid. As a result, the current will increase rapidly, and the temperature will rise accordingly, which will easily cause the motor to burn out. Therefore, it is necessary to ensure that the motor always works at the rated current and pay attention to checking the operation of the transmission device, the concentricity of the coupling, and the gear transmission.
3. Pay attention to checking the temperature of the motor. Workers should always check the temperature of the bearing, stator, and housing of the motor. Especially for motors without voltage, current, and frequency monitoring and without overload protection, they should pay more attention to monitoring the temperature rise. Too high, you should stop the inspection immediately. In addition, the rolling elements of the bearing, the surface of the raceway, the bearing clearance, etc., need to be checked regularly. If any abnormality occurs, you must renew the bearing before the operation.
4. Observe the motor for vibration, noise, and abnormal odor. If the motor vibrates, the concentricity of the load part connected to it will increase. Increasing the motor load will overload the motor and burn it. Noise and odor are precursors to motor failure and must be watched at all times. Therefore, during the operation of the motor, especially the high-power maintenance network motor, it is necessary to frequently check to see if the motor end cover, anchor bolts, bearing glands, etc. have become loose, etc., once the problem is found, you must resolve it in time.
5. To ensure the normal operation of the starting equipment, Generally speaking, the quality of the starting equipment determines whether the motor can start normally. According to previous experience, most of the burned motors are caused by the abnormal operation of the starting equipment, such as lack of phase of the starting equipment, arcing of the contactor contacts, and ignition. So how to maintain the startup equipment? It is mainly cleaning and tightening. For example, the contactor contacts are not clean, which will increase the contact resistance, cause the maintenance network to burn and burn the contacts, and then burn the motor. Therefore, always pay attention to the cleaning and tightening of the starting equipment. In addition, the electrical control cabinet should be set in a dry, ventilated, and easy-to-operate position and regularly dust-removed.