200-240VAC 2x16A Dual-Input Switched Rack PDU with KN-1 Protection Monitoring

Brand Name:ESTEL
Certification:ROHS
Model Number:1h16QPTKN1D1-8E2G
Minimum Order Quantity:1 set
Delivery Time:15-20 working days
Payment Terms:L/C, D/A, D/P, T/T, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 3A-8, SHUIWAN 1979 SQUARE (PHASE II), NO. III, TAIZI ROAD, SHUIWAN COMMUNITY, ZHAOSHANG STREET, NANSHAN DISTRICT, SHENZHEN
Supplier`s last login times: within 35 hours
Product Details Company Profile
Product Details

200-240VAC 2x16A Dual-Input Switched Rack Power Distribution Unit


1. Power Distribution Unit Product Specification Parameter Description:


Customer nameNO.Product specification parameter description
Product namePower switch1Socket system and numberIEC320 C19 (2); IEC320 C13(8)
Product specification and model1h16QPTKN1D1-8E2G2Internal connecting line16AWG,14AWG,copper Stick
Product code3Power supply input modeC20 socket
Product quantity4Cable plug system/
RoHSYES5Cable specifications/
Customer product code/6Cable installation modeBack dual input
Customer product specification and model
7

Cable fixing

/
8Shell colorBlack
Special product descriptionRemovable controller9Size and specification(L*W*H)484*250*44mm
10Fixed hole center distance465mm
11Aluminum alloy shell length/
12Product installation modeBracket installation
13Installation direction of bracketHorizontal formal
Factory accessories4 pcs for each M6 screw and nut14Control indication function1P/16A CB(Prevent misoperation)
15Protection monitoring functionKN-1
Product identificationProduct namePower switch
Customer specifications and models1h16QPTKN1D1-8E2G
Rated voltage and current200-240VAC 2*16A
Safety certification mark/
LOGO/
ManufacturerESTEL

2. Power Distribution Unit Product Renderings:



3. Intelligent PDU Function Comparison Table:


FeaturesDescriptionPerformance ParametersKN series gradeNotes
1
Operating supply voltageThe voltage required for the normal operation of the productAC230V or AC400V

Maximum input and output currentProducts can work long-term current

16A or 32A

Or 3x16A or 3x32A

Operating power frequencyThe voltage required for the normal operation of the product47~63Hz
Access interfaceNetwork portAccess monitoring via Ethernet or LAN10/100Mb network adaptation
Network portLevel even portBuilt-in network switchReserving
Serial portAccess through the serial port monitoringRS485 interface
RS232 interface ( select one with RS485 interface)Selection
Peripheral interfaceSensor interfaceRS485 interface
interview method

HTTP/

HTTPS

Browser mode accessCompatible with IE , FireFox and other popular kernel browsers , supporting SSL
TELNETSimple command line access/
SSHEncrypted command line accessSupport SSHv2 version
SNMPSupports common simple network management protocol centralized monitoringCompatible with protocol versions such as SNMPv1/v2c/v3
Operating system compatibilitySupports multiple operating systemsThe monitoring terminal is compatible with mainstream operating systems such as Windows//win7/linux
Secondary developmentFor customer system integrationDevelopment agreement TELNET, SSH
RS485Support customer agreement customization
Software upgradeManagement software loadingSupport management software updates
controlControl each output on and offEach output breaking capacity 16A 250VAC
Power up and down in sequenceSequential power-off time interval 0.5s , sequential power-on time interval 1~60s can be set to prevent the power equipment from simultaneously starting the interference equipment, polluting lines, and the total brake line is not on
Power offAfter the PDU input is powered off and restarted, the state of each output switch maintains its original state.
MonitoringDetect each output fuse stateCan detect that the fuse is disconnected or the output switch does not turn on and off properly
Monitor input voltage

Resolution : 1V

Accuracy: ± 1% +1 word

Range: 90~350V

Monitor the total input and output current

Resolution : 0.1A

Accuracy: ± 1% +1 word

Measuring range: 0.1~40A

Monitor each output current

Resolution : 0.1A

Accuracy: ± 1% +1 word

Measuring range: 0.1~20A

Monitor each electrical enery

Resolution : 0.1KW ·H

Accuracy: Level 1

Monitor each active power

Resolution: 1W

Accuracy: ± 1% +1 word

Monitor each power factor

Resolution: 0.001

Accuracy: ±1%+3 words

Monitoring total power

Resolution : 0.1KW ·H

Accuracy: Level 1

Monitor breaker status/Have not ,but optional
Monitoring ambient temperature

Resolution : 1 °C

Accuracy: ± 1% +1 word

Measuring Range: -30~100℃

Have not ,but optional
Monitoring environmental humidity

Resolution : 1%

Accuracy: ± 1% +1 word

Measuring Range: 01-99%

Have not ,but optional
Monitoring environmental smokeMaximum effective 25㎡Have not ,but optional
Monitoring environmental floodingCan monitor dew, water immersion environmentHave not ,but optional
Infrared monitoring of environmental personnel enteringMaximum detection distance 16mHave not ,but optional
Door and window monitoringMinimum opening distance 5mm effectiveHave not ,but optional
Anti-surge, lightning protection failure monitoringDoes not affect the normal use of the product after failureHave not ,but optional
Alarm limitTotal current limitAutomatic identification of limits
Each output current limitAutomatic identification of limits
Environmental temperature limitsAutomatic identification of limits
Environmental humidity limitsAutomatic identification of limits
Alarm outputEach fuse alarm

PS/PN local alarm mode: PDU alarm site inspection, output sound and light, dry contact.

PN remote alarm mode: E-mail, SMS, SNMP TRAP , WEB page prompt, TELNET/SSH prompt

Each output current limit alarm
Total current overload warning
Temperature overrun alarmHave not ,but optional
Humidity limit alarmHave not ,but optional
Smoke alarmHave not ,but optional
Flooding alarmHave not ,but optional
People enter the alarmPN remote alarm mode: E-mail, SMS, SNMP TRAP , WEB page prompt, TELNET/SSH promptHave not ,but optional
Open door / window alarmHave not ,but optional
Anti-surge, lightning failure alarmHave not ,but optional
Display, instructionsOutput indicatorOne output per indicatorHave not ,but optional
LCD displayDisplay current voltage, display product information, alarm information
Digital tube displayDisplay current voltage, display product information, alarm information
Key menu operationsearch informationQuery display product information, alarm information, current, etc.
On / Off alarm sound and dry contactTurn off / on alarm sound and dry contact output. Dry contact output has two options, normally open and normally closed. Passive, contact can be connected to 2A 250VAC.
ProtectionLightning surge

Differential mode: ± 2kV

Common mode: ± 2KV

Through traffic : 3KA

Discharge current: 5KA

Have not ,but optional
Each with a fuse

Insurance tube breaking force 1500A;

To prevent the main line from being powered off, disasters occur in the power equipment and lines, and the fuse can be equipped with 0.1~16A

Have not ,but optional
Circuit breaker protectionSwitch the power supply to prevent short circuit affect the main line, to prevent electrical equipment overload disaster, breaking force 5000AHave not ,but optional
Recoverable overload protectionPreventing Overload from Electrical Equipment and DisastersHave not ,but optional
RecordAlarm logCyclic alarm log, you can query, export, save, delete
ManagementUser management authorityDistinguish between administrator and general personnel rights
Output group management/
Clock synchronizationCorrect product system clock
Named managementSupports naming operations such as PDUs , output bits, and sensors for easy management
Intelligent RecognitionIntelligent identification outputAutomatically identify the output format, number of digits
Intelligent identification sensorThe sensor interface does not need to be defined. The access can identify the sensor type and quantity.
Intelligent identification limitsWhen the limit is out of range, the setting is invalid
Intelligent identification of the product's maximum output current and current product access device powerHelps managers control the number or type of product access
Intelligent identification of power factorHelp customers understand the power consumption of customer equipment and can be used as a reference for energy consumption
Sensor access1~8 same or different types of sensors connected at the same timeSensor access, expansion, and flexibility to design new sensors based on new customer needsHave not ,but optional

China 200-240VAC 2x16A Dual-Input Switched Rack PDU with KN-1 Protection Monitoring supplier

200-240VAC 2x16A Dual-Input Switched Rack PDU with KN-1 Protection Monitoring