External Dimension H×W×D 1800×1000×1000mm
One compartment
Equipment Installation Method:19” standard rack
With one front door and one back door, totally two doors;
with anti-theft three point lock for outdoor cabinet (support padlock)
Material :Single wall 1.5mm Galvanized Steel with heat insulation
Ingress Protection:IP55
Temperature Control:DC48V 500W Air Conditioner
LED lamp:48V LED lamp
Working Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
Humidity Relative Humidity 5% ~99%
Air Pressure :62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Solar Radiation Intensity:1124 × (1±5%)W/m2
Accessories List
No. | Item | Quantity | Unit | Specs |
1 | Outdoor Telecom Cabinet | 1 | Set | (1) External Dimension H×W×D 1800×1000×1000mm (2) One compartment; (3) With one front door and one back door, totally two doors; with anti-theft three point lock for outdoor cabinet (support padlock) (4) Material: galvanized steel; with heat insulation |
2 | Air Conditioner | 2 | Set | Power Supply: DC48V Cooling Capacity:500W Model: SAD105 |
3 | Power Distribution Unit | 1 | Set | Grade B Lightning Proof AC Input: 63A/2P *1; AC Output: 16A/1P*4; DC Output: 16A/1P*4. Height: 4U |
4 | Environment Monitoring System | 1 | Set | 1× environment monitoring unit 1× water sensor; 1× smoke sensor; 1× temperature and humidity sensor; 2× door sensor. |
5 | LED Lamp | 2 | Pc | DC48V |
6 | Door Sensor | 2 | Pc | Used for Controlling LED lamp on/off |
7 | Package | 1 | Set | Wooden Case |
Compact and light double-walled design
Highest protection against corrosion
Features an integrated roof
Thickness of plate: 1.5mm
with heat insulation ,Polyester powder coat with UV protection
PUR non-porous gasket—suitable for extreme temperatures
Fully welded design, supplied complete, no assembly required
Surface finish: Degreasing, pickling, phosphoric wash, cleaning,
and powder coated
This cabinet is 1800mm High and 1000mm Wide and 1000mm Deep. This
cabinet represent a suitable solution for projects with high
requirements on stable in-rack climate. They are specifically
designed for mounting onto a column.
● Cooling solution: We adopt Air conditioner to control temperature
ensuring the best working condition inside the cabinet.
● Power distribution unit: can meet the requirements of power
system normal operation and equipments maintenance
●Sensors: can monitor internal temperature,humidity,fire/smoke,door
opened state.
● Light: one piece LED tube light is for lighting insde and fixed
on the top cover.
● Strong rack inside to be equipped with telecom equipments, power
source, temperature control device and other attachments.
● Digital display the temperature-setting, temperature alarm,
temperature parameters inside and outside, and all kinds of other
alarm information, etc.
-Ingress protection is IP55, we can provide IP65 cabinet based on client’s actual.
-Made of heavy gauge galvanized material.
-Front door use standard three-point anti-theft lock. The door lock forms an upper, middle and lower three-point locking structure. For the cabinet with large area, the locking effect is safe and reliable.
-Standard 19 inch mounting posts.
-Doors secured with steel dead locking system lock (support PADLOCK)
-It is installed in the ground root or above ground column base system by "direct burying"
-Cable entry is via the base as standard with side or roof entry available upon request.
The cabinet includes 19” equipment installation rack. The cabinet includes two air conditioners, one installed on front door and another installed on back door.
The cabinet includes one front door and one back door. The cabinet
door uses embedded structure. The door opening angle is larger than
110°and the door limit device can limit the opening angle. The lock
is theftproof three point lock, supporting padlock. Each cabinet
door include open door sensor, working together with the
environment monitoring unit.
LED lamp, LED lamp sensor, smoke sensor, door sensor and temperature & humidity sensor are installed at the top of the cabinet.
Water sensor is installed at the bottom of the cabinet.
PDU and environment monitoring unit are installed on 19” rack.
The cabinet includes totally two air conditioners, one air
conditioner installed on front door and the other installed on back
door.
Cable Inlet
Feeder cable and other external cables all use bottom wiring
method.