Home /Inverters & Converters /

DC / AC 1000VA Sine Wave Inverter Flush Mounting Power Supply AC Bypass Input

DC / AC 1000VA Sine Wave Inverter Flush Mounting Power Supply AC Bypass Input

Brand Name:ESTEL
Certification:ISO9001, CE, 3C, FCC, TLC, IP55
Model Number:GPDA1000VA-F
Minimum Order Quantity:1 set
Delivery Time:15-20 working days
Payment Terms:T/T, L/C,D/A, Western Union, Paypal, etc
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Shenzhen, China
Supplier`s last login times: within 35 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

AC Bypass input RS485 Communication Function DC / AC 1000VA Sine Wave Inverter Flush Mounting Power Supply


1. Product Description


GPDA1000VA-F is one kind of two outputs, with AC bypass input, with 485 communication function DC / AC 1000VA sine wave inverter flush mounting power supply, the entire power supply using the latest circuit design, compact structure, reliable performance, high output efficiency. Entire power in strict accordance with safety requirements designed to meet the IT equipment safety standards.


2. Electrical Specifications


Input
ParameterMin.TypicalMax.UnitNote
DC inputDC operating voltage range4060Vdc
Input rated voltage48Vdc
Input Rated Current30ARated input, rated output
Power input Max Surge Current45A≤ 150% of rated current
AC inputAC operating voltage range175265Vac
Input rated voltage220Vac
Input Rated Current5A

Export
ParameterMin.TypicalMax.UnitNote
The inverter outputRated output voltage220VacEnter the full voltage range
Rated output current4.6A
Output voltage accuracy±5%Enter the full voltage range
Rated output frequency495051Hz
Rated Capacity1000VA
Rated output power1000W
Overall efficiency85%Rated operating conditions
Output power factor0.8Rated operating conditions
Dynamic transient recovery time60ms
WaveformSine wave THD <3% (linear load)
Sine wave THD <8% (linear load)
Overload105~ 125% for not less than 10 minutes to 125 to 150% for not less than 10 seconds.
Output current crest factor3: 1
OutputTwo AC output
AC bypass outputOutput voltage range175265VacWith the AC input voltage changes
Rated output voltage220Vac
Rated output current5A
Switch to mains inverter output time10msRated load
Mains to inverter output time10msRated load
OutputTotal output of the inverter, the inverter when an input under voltage, overvoltage, fan failure, over-temperature protection, switching to bypass output.

Protection
ParameterMin.TypicalMax.UnitNote
Inverter partDC input voltage protection point36VdcEnter under voltage protection, the inverter output bypass switch.
DC input voltage recovery point40VdcAchieve recovery value, one minute to restore the inverter output.
DC input voltage recovery hysteresis2Vdc
DC input voltage protection point66VdcEnter overvoltage protection, the inverter switch to bypass the output.
DC input overvoltage recovery point60VdcAchieve recovery value, one minute to restore the inverter output.
DC input overvoltage recovery hysteresis2Vdc
Input over current protectionPower supply with input over current protection, can not be automatically restored.
Over Temperature ProtectionPower supply with over-temperature protection. When inside the main heat sink temperature is too high, over-temperature protection point reached, the inverter output bypass switch, temperature hysteresis of 10℃ or so.
Anti-reverse protectionPower supply with input anti-reverse protection. When reversed, the power does not work, and no damage.
Short circuit protectionPower supply with short circuit protection. When the power fails short intervals of one minute start time, 6 minutes lift failure, can be recovered. Long-short, the power shutdown, the short is removed, you can manually re-boot after work.
Output over current protectionPower supply with over current protection. Detect over current, output power is turned off, every one minute start time, when the load back to the ratings, self-recovery. Long-term overload, power off, you can manually reboot after work.
Alarm (buzzer alarm)DC input error, overload, short circuit, inverter fault, the buzzer alarm.
AC bypass sectionInput over current protectionBypass input section having an input over current protection function (≥ 10 A), non-self-recovery. The need to manually replace the fuse before working again.

Environment
ParameterMin.TypicalMax.UnitNote
Operating ambient temperature- 20+5 5° C
Inverter temperature storage environment- 25+70° C
Relative humidity095%Relative humidity, dew does not pour
Altitude15 00mMeet derating requirementsGB3859.2-93
CoolingNatural air. With the power of wind turbines internal temperature rises enhanced, cold heat.
Work EnvironmentNo conductive dust explosion, corrosion and destruction of gases and vapors, no severe vibration and shock

5. Product Dimensions


6. Product Pictures



China DC / AC 1000VA Sine Wave Inverter Flush Mounting Power Supply AC Bypass Input supplier

DC / AC 1000VA Sine Wave Inverter Flush Mounting Power Supply AC Bypass Input

Inquiry Cart 0