Home /Power Distribution Equipment /

Custom Double Wall PDU Base Station Cabinet , Outdoor 19'' Rack Enclosure

Custom Double Wall PDU Base Station Cabinet , Outdoor 19'' Rack Enclosure

Brand Name:ESTEL
Certification:ISO9001, CE, 3C, FCC, TLC, IP55
Model Number:DDTE056
Minimum Order Quantity:1
Delivery Time:15-20 working days
Payment Terms:L/C,D/A,T/T, Western Union, Paypal, etc
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Shenzhen, China
Supplier`s last login times: within 35 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Custom Double Wall PDU Base Station Cabinet , Outdoor 19'' Rack Enclosure

Quick Details:


Place of Origin: Shenzhen, China (Mainland)External Dimension: H×W×D 1500×1800×900mm

Brand Name: ESTEL

Structure: double wall, with insulation, sandwich structure.

Model Number: DDTE056

Cabinet Layout: two compartments

Product Name: Outdoor Integrated Telecom Cabinet

Cabinet Lock: anti-theft three point lock
Certification: ISO9001, CE, 3C, FCC, TLC, IP55

Protection Level: IP55

Application: outdoor telecom base stationCable Entry: at cabinet bottom
Material: galvanized steelIllumination: DC48V LED lamp

Heat Insulation: PEF

Grounding Protection: copper bar

Color: grey (support custom made)

Cooling: AC220V air Conditioner and fans

Coating: anti-corrosion outdoor powder coating

Accessories Options: PDU, environment monitoring system

Payment & Shipping Terms:


Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:L/C,D/A,T/T,Western Union, Paypal, etc
Supply Ability:6,600 sets per month
Delivery Time:15-20 working days
Packaging Details:wooden case

1. Specifications

(1) Technical Parameters


ItemTypeTechnical Parameter
StructureDimensionExternal Dimension: H×W×D 1500×1800×900mm
Layout2 compartments
Equipment Installation Method19” rack
DoorWith two front doors and two back doors, and anti-theft three point lock for outdoor cabinet (support padlock)
MaterialGalvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate
Heat InsulationThere are heat insulation between inner wall and outer wall. The insulation material is 20mm PEF.
StructureWelded
Ingress ProtectionIP55
Temperature ControlCoolingAC220V air conditioner and fans
Lightning ProofGrade B lightning proofNominal: 60KA, Max.: 100KA
LightingLED lamp48V LED lamps (immovable), with protective circuit breaker
TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
HumidityRelative Humidity5% ~ 100%
PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation IntensitySolar Radiation Intensity1120 ×(1±5%)W/m2

(2) Accessories List


No.ItemQuantityUnitSpecs
1Outdoor Telecom Cabinet1Set

(1) External Dimension: H×W×D1500×1800×900mm;

(2) Two compartments: the left and the right parts are equipment compartments;

(3) With two front doors and two back doors, and anti-theft three point lock for outdoor cabinet (support padlock)

(4) Material: galvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate;

(5) There are heat insulation between inner wall and outer wall. The insulation material is 20mm PEF.

2Air Conditioner2Set

Cooling capacity: 1.3KW, AC220V, 50HZ;

Model:TC06-130JFH/01

3Auxiliary Direct Ventilation Fans3PC12038 DC48V
4Environment Monitoring Unit1Set2U, Model: SM2200
5Water Sensor1PC
6Smoke Sensor1PC
7Temperature and Humidity Sensor2PC
8Door Sensor8PCOne for controlling LED lamp, the other for open door alarm
9LED Lamp4PCDC48V
10Power Distribution Unit1Set

Grade B Lightning Proof

AC Input: 63A/2P *1;

AC Output: 16A/1P*4;

DC Output: 16A/1P*4

11Package1SetWooden Case

2. Description


The cabinet is two compartments cabinet. The cabinet cooling use air conditioner and fans, to ensure the equipments operate normally at stable temperature range, so as to make the service life of the equipments much longer and their performance more stable.

2.1 Wire Routing Design


Feeder cable and other external cables all use bottom wiring method.


2.2 Grounding Protection


  • The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
  • The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
  • Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.

2.3 Door lock theft proof design


(1) Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.



(2) Three point lock


2.4 Connection and Fastening


  • Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
  • Door hinges use inner hinge mode.

2.5 Appearance and Surface Treatment


Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.


3. Applications


The DDTE056 Outdoor Telecom Equipment Cabinet is mainly used in wireless communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission,

etc.


4. Packing and Shipping



Our Delivery Agent


The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


5. Our Contact Information


Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10

Website: www.estelecomcabinet.com

China Custom Double Wall PDU Base Station Cabinet , Outdoor 19'' Rack Enclosure supplier

Custom Double Wall PDU Base Station Cabinet , Outdoor 19'' Rack Enclosure

Inquiry Cart 0