Add to Cart
Optical Cable Mechanical Testing Machine Integrity Testing White
1KW Adjustable
Scope of application:
Suitable for testing cable or optical cable under the flame of not
less than 750 ℃, for when the fire is keep line integrity, and test
cable or optical cable in not less than 830 ℃ for offensive and
exert impact conditions, whether to keep the line’s integrity.
Meet the standard:
In line with the GB/T19216.11 also 99-2003 / IEC60331 - "under the
condition of fire cable and optical fiber cable line integrity test
part 11: test unit - the flame temperature is not lower than 750 ℃
separately for fire" standard requirements;
Comply with GB / / IEC60331 T19216.12-2008-02 deprives the under
the condition of fire cable or optical cable circuit integrity test
part 12: test apparatus, the flame temperature is not lower than
830 ° C for offensive and exert impact "standard requirements;
In accordance with GB/T19216.21-2003/ iec60331-21:1999, line
integrity test of cables and cables under flame conditions section
21: test procedures and requirements - rated voltage 0.6/1.0kv and
the following cables;
In accordance with GB/T19216.23-2003/ iec60331-23:19 99, line
integrity test of cables and cables under flame conditions section
23: test procedures and requirements - data cables;
In accordance with GB/T19216.25-2003/ IEC60331-25:19 99 in the
flame condition, the circuit integrity test of cables and cables is
part 25: test procedures and requirements - optical cable;
In accordance with GB/t19216.31-2008 / iec60331-31:2002, the line
integrity test of cables and cables under flame conditions section
31: test procedures and requirements for fire and impact - rated
voltage 0.6/1.0kv and below cable.
Main features:
Control system:
Using the assembly control system and high performance acquisition
control card, automatic data acquisition and processing, data
saving and output results can be realized.
The equipment has the following safety protection devices: power
overload, short circuit protection and overload protection of
control circuit. It has power failure, short circuit, alarm,
indicating fire breakdown current: 3A (automatic alarm cut-off
power and gas supply system after sample breakdown).
Adopt imported high quality devices to ensure high quality, high
speed and stable operation and advanced technology.
The automatic control mode test is adopted to realize automatic
detection control, automatic completion of detection work, and
humanized control interface, making the detection work more
convenient, faster and more accurate.
Automatically generate temperature control curve and report output,
data collection and printing test results.
Main parameters:
The main four components of the circuit integrity tester of cable
and optical cable are the combustion chamber, combustion system,
control room and assembly control system.
Burner: a type propane gas burner with a 500mm length of flame
surface with venturi mixer. The nominal width of the fire-breathing
surface is 15mm, and the nominal diameter of three rows on the fire
surface is 1. 32mm, center distance is 3. 2mm drilling.
Gas control system: the control valve, high-pressure automatic
ignition and flameout device, the control thermocouple, propane,
spiral valve, pressure gauge, flow meter, venturi mixer, burner,
ball valve, compressed air tank, etc.
Flame temperature: 750 ° ~ 1000 ° is adjustable.
Combustion gas: a purity of 98 % propane.
Combustion gases: compressed air. (air pressure should be above
10Mba.)
Flow meter: the rotor flow meter is used.
Air flow: 0~ 200L/min.
Propane (gas) flow: 0~ 20L/min. Flow adjustable.
Thermocouple: vertical thermocouple, horizontal thermocouple.
Validation decision: two thermocouples in 10 min time average
readings within the (750 + 050 ℃) requirements, and the maximum
difference in the two thermocouple readings average no more than 40
℃, should think through validation.
Validation average: at least every 30s.
Verification timer: 0~ 99. The 99min will automatically stop when
it reaches the set value.
Verify accuracy: plus or minus 1s/h.
Ignition device: automatic ignition with high voltage pulse.
Supply time: 0-999min
Power supply requirements: AC380 (plus or minus 10%) V/50HZ.
Machine operation power: 1KW.
Test voltage (phase voltage) : 0-1000v continuously adjustable.
GB/T19216.25 standard continuity inspection device: optical
instrument continuity check, optical instrument customer self -
preparation.
Technical services:
1. 20 years of brand commitment, patent quality, quality assurance,
superior performance, excellent quality and full service;
2. 20 years of brand communication, professional team, professional
technical and technical consultant, and the cooperation of various
quality inspection institutes and schools;
3. Provide free service for the whole year, five quality control
procedures, from material input to product handover control
quality, ensure that the user is absolutely authentic;
4. The brand effect absolutely guarantees the quality of the
products, and we provide high quality products with high quality
products and the highest cost performance to ensure the testing
data, and the guarantee of the company;
5. 18 professional technicals will solve any problem in your
products. Professional after-sales team will provide you with the
most beautiful service;
6. Free teaching research, equipment maintenance and free upgrade
of equipment server;