Add to Cart
2P lightning protector household lightning protection Max continuous operating voltage 275V
Working principle of product
Surge protector and its voltage limiting functional element are
composed of metal oxide varistors in parallel. Each varistor
requires an independent disconnector. The principle of the
disconnector is a heat release. The function is disconnected
through the low temperature welding point and is separated from the
metal rod by its own elastic action. After disengagement, the red
indication will appear in the transparent window on the front side
of the surge protector. It is installed in the main power
distribution cabinet and outdoor power distribution cabinet.
Product features
1. troubleshooting automatic reset
2. use the pluggable module set up, the maintenance is simple
3. leakage current is small, the response time is fast, and the
residual pressure is low
Four
Product specification
|
Product introduction
Surge protector is the lightning protection measures taken by
Zhejiang toer Electric Co., Ltd. for its own development and
production. When equipment short circuit and power switching are
likely to cause surge, the surge occurs in only a few millisecond
time, which will have great harm to the equipment. The surge
protector can react and effectively absorb the huge energy of burst
at this time, so as to protect the connecting devices from being
damaged.
Use of attention
1. connect the grounding wire of the lightning protector with the
ground wire of the lightning protection system.
2. it should match the working voltage of the protected equipment.
Please install according to the installation sketch.
3. this product needs no special maintenance. The lightning
arrester should be checked regularly, especially in the
thunderstorm season and the whole thunderstorm period. When the
system fails to doubt the lightning arrester, the lightning
arrester can be dismantled and rechecked. If the system is restored
to normal after the restoration to the state before use, it
indicates that the lightning arrester has been damaged and must be
replaced immediately.
Company profile
Thor has been designing new products to meet the RoHS directive
since 2006. Thor’s ongoing commitment to RoHS compliance includes
continuing efforts to reduce the presence of hazardous substances
in the design and manufacture of a growing number of popular
products.
All types and classes of our lightning and surge arresters
20KA~200KA(8/20μS) and 15KA~50KA(10/350μS) are tested and pass all
the requirements based on their class.