RJ11 control signal, lightning protector, automatic surge protector, analog signal, lightning protector.
Working principle of product
The control signal surge protector is connected to the front end of
the protected equipment. When the transmission line is impacted by
the inductive thunder and other transient overvoltage, the impact
current is discharged to the earth through the protection branch of
the surge protector, and the output voltage is placed in the
allowable voltage range of the equipment, thus ensuring the safety
of the operating equipment.
Product features
1. it has three protection functions of over current, over voltage
and clamping.
2. the low attenuation and return loss in the wide frequency range
ensure that the lightning arrester does not affect the system
performance.
3. the off state leakage current is extremely low, which does not
affect the normal operation of the device.
Product specification
Model and specofocation | TRSS-RJ11 | ||||||
Rated Operating Voltage | Un | 110V | |||||
Max continuous operating voltage | Uc | 150V | |||||
Voltage protective level | Up(V)〈 | 〈500 | |||||
Max discharge current | Imax(8/20μS) | 5kA | |||||
Nominal discharge current | In(8/20μS) | 3kA | |||||
Response time | ns | ≤1 | |||||
Adaptive date transfer rate | 2Mbps | ||||||
Insertion loss | ≤0.5dB | ||||||
Configuration dimension | 52×25×25 | ||||||
Operating condition | Temp:-40℃~+70℃ | ||||||
RH≤95%(25℃) | |||||||
Sea level elevation≤3km | |||||||
Remarks | Other max continuous operating voltage can be | ||||||
customized(12V.24V.48V) |
Brief introduction
The control signal lightning arrester is a lightning protection
measure developed by Zhejiang tohr Electric Co., Ltd., which is
independently developed for signal circuit protection. The product
is typically used for communication serial ports such as computers
RS485 and RS422RS232. It is protected from damage caused by
lightning induced voltage, grid voltage fluctuation, electrostatic
discharge and impact voltage. It can be used for the protection of
industrial control interconnected network, RS422/485 interface,
special line, automatic control and instrument line, data line and
telephone equipment, fax machine and so on. It can also be used for
the protection of sensors and two instruments in the current ring.
Use of attention
1. "IN" connects the lead end, "OUT" connects the protected device
(or system) end, "1" and "3" as a signal channel, "2" and "4" as a
signal channel. When installing, the two ends must be laid
separately, and not be tied together to prevent the two induction.
2. "IN" connects the lead end, "OUT" connects the protected device
(or system) end, "1" and "3" as a signal channel, "2" and "4" as a
signal channel. When installing, the two ends must be laid
separately, and not be tied together to prevent the two induction.
3. the lightning arrester is not required for long maintenance
without longer maintenance. It only needs to be maintained by the
system. In the course of use, the signal transmission is problem
and the signal transmission is restored to normal after the surge
protector is replaced, indicating that the surge protector has been
damaged and needs to be repaired or replaced.