

Add to Cart
Three phase power supply lightning protection box, 220V belt counter, elevator villa, power supply protection
Product introduction
The lightning protection box for single phase power supply is
designed according to the standard of IEC and GB. It is equipped
with power supply instructions, lightning protection instructions,
deterioration alarm and instructions, lightning counter and
lightning fuse wire. It is mainly installed in the distribution
room, distribution cabinet, AC distribution screen, switch box and
other important equipment, easy to be struck by lightning
equipment, in order to protect and set up. It is protected against
damage caused by lightning overvoltage along the power line.
Product specification
Model | TRSX-60 | TRSX-80 | TRSX-100 | TRSX-200 |
Rated Operating Voitage | 385 | 385 | 385 | 385 |
working voltage | 380 | 380 | 380 | 380 |
Working frequency (HZ) | 40~60 | 40~60 | 40~60 | 40~60 |
Voltage protection level (KV) | 1.8 | 1.8 | 1.8 | 1.8 |
Maximum flow rate (KA) | 60 | 80 | 100 | 200 |
response time | L-N 25NS N-PE | |||
Protection mode | L-N/L,N-PE | |||
Terminal terminal | Maximum 35mm2 |
Product features
1. application new clamping technique
2. use special impact melt sheet
3. lightning protection failure indication
Working principle of product
In the normal working condition, the lightning protection module is
in the disconnected state and does not affect the normal work. When
the line has the impulse overvoltage at the moment when the
lightning strikes, the lightning arrester module quickly passes
through the very short time, short the overvoltage to the earth,
and when the pulse overvoltage disappears, the lightning arrester
module is resumed to disconnect. State, which does not affect the
power supply of the user.
Use of attention
1. protector is applied to the lightning protection of the main
power distribution system C level, and is installed on the incoming
end of the main distribution cabinet, the distribution cabinet or
the terminal electric cabinet in parallel.
2. all wiring must be firmly and reliably connected
3. ground wire is less than 1 meters
Company profile
Thor is all about protecting against the damaging effects of power
transients. It is our goal and mission to connect our customer
challenges with high-quality, right-priced solutions and products –
completed by unrivaled customer service and technical support.
Thor has been designing new products to meet the RoHS directive since 2006. Thor’s ongoing commitment to RoHS compliance includes continuing efforts to reduce the presence of hazardous substances in the design and manufacture of a growing number of popular products.