The diamond CA-23RP coaxial lightning arrester type BNC interface antenna signal lightning arrester
Brief introduction
The BNC interface lightning protector is a design of lightning
protection applied to the antenna feeder system based on the
relevant standards. It is suitable for all kinds of radio frequency
transceiver systems, wireless network signal transmitting,
satellite TV receiving equipment and monitoring signal wireless
transmitting and receiving equipment. It has high effective defense
function for lightning impulse pulse induced on the feeder line,
and can prevent the antenna and receiving and receiving equipment
caused by the feeder line induced lightning overvoltage. Damage.
Product specification
Model and specofocation | TRSW-BNC | ||||||
Frequency range | DC-1.5 GHz | ||||||
Working voltage | 500V | ||||||
Nominal discharge current | In(8/20μS) | 10kA | |||||
Insulation resistance | ≥5000 MΩ | ||||||
Dielectric withstanding voltage | 1500V | ||||||
Impedance | 75Ω | ||||||
Interface mode | BNC.N.UHF.TNC and so on | ||||||
Operating condition | Temp:-40℃~+70℃ | ||||||
RH≤95%(25℃) | |||||||
Sea level elevation≤3km | |||||||
Remarks | Other max continuous operating voltage can be customized |
Working principle of product
The lightning protection device is based on the principle of
standing wave antenna and lightning wave spectrum design. The main
part is a short rod equivalent to the end of the 1/4 wavelength.
When the signal is sent out, a part of the impedance is reflected
back because the impedance is not fully matched, and the wave will
form a standing wave when the wave is superimposed on the incident
wave originally emitted. The amplitude of standing wave at each
point of the line is fixed first. For the transmission line with
terminal short circuit, the terminal is short circuited, so the
current is large and the voltage is small. For the signal end, the
voltage and the current are small.
That is, the most close to the open circuit of the signal terminal
impedance, so the loss is small, but for the lightning wave because
of its wide spectrum range, and most of the energy is concentrated
in the frequency band below 10HZ, so the short circuit rod is short
circuited to the lightning, and will not invade the equipment to
cause damage.
Use of attention
1. the joints of most antennas are N type, so the two connectors of the surge arrester are two N heads. One is the N public (the antenna), and the other is N mother.
2. in order to reliably prevent thunder and lightning, we can
connect each antenna output terminal and the input terminal of the
protected device to a lightning feeder. In areas where lightning is
less, only one antenna can be used without amplifier.
3. lightning arrester should be connected to the feeder line and installed near the protected equipment.
Product features
1. exquisite workmanship, able to work in bad environment for a
long time.
2. extremely low stationed Bobbi, ensure that the lightning
arrester does not interfere with the normal operation of the
system.
3. low capacitance, inductance design, superior transmission
performance