Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification

Brand Name:HICORPWELL
Certification:IEC 60794-2-10/11
Model Number:HCW-325 Fiber Optic Visual Fault Detector
Minimum Order Quantity:1pcs
Payment Terms:Western Union, L/C, T/T
Place of Origin:China
Contact Now

Add to Cart

Site Member
Location: Shenzhen Guangdong China
Address: Rm 604 Bldg 9th Yinxingyuan South Rd Nanshan District 518054 Shenzhen China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification


Method of Using :


1. Screw the end cap from the pen, the battery will be prepared into the pen, battery cathode to the end cap, the positive on the pen body is positive;(note: please do not turn pen and pencil tail into the battery)


2. Put the pen and pencil body connection installed, open the dust cap, press the control switch one time, observe the interface has a red light, luminous tube on at the same time;(note don't eyes were light interface, so as not to damage the eye)


3. Press the control switch again, observe the light into a pulse mode, the indicator light-emitting tube and out of sync pulse light;(pulse frequency in 2-3 hz or 9 hz)


4. Press the control switch again, light source closed, no light output, at the same time indicator light pipe out;(switch mode to: continuous - pulse - closed - continuous cycle mode)


5. When detecting insert tested optical fiber optical interface, press the control switch at the same time, choose the output light work mode (continuous or pulse);


6. After use, build the dust cap, do not use for a long time, please take out the battery, in order to avoid battery rot, damage the light source.


Maintenance and matters needing attention


1. Laser and harmful, especially to pay attention to protect the eyes, when laser works, avoid to irradiate the eyes with laser directly;
2. In generally, the higher the temperature, the shorter the life of laser, when used to avoid high temperature working environment;

3. The work of laser optical fiber head should be cleaned;

4. When used, the optical interface and the interface needs to detect light and light pull plug;

5. Don't use the light source, would you please put dust cap to avoid dust fall;

6. Should remove the battery when not in using;

7. Please do not remove the end cap and any part of the dust cap, remove shall not be responsible for damage caused.Fiber Checker Fiber Tester Tools Optic Visual Fault Detector network fiber checker fiber optic visual fault detector

ModelHCW-325
Central wavelength650nm±10nm (635nm is available on request)
Emitter typeFP-LD
Output power50MW
Laser Range≥50km
Optical connector2.5mm universal connector, for 1.25mm connectors, FC (Male)-LC. (Female) convertor can be provided on request
Operating modeBoth CW and Pulse available
Pulse frequency2Hz to 3Hz / 9Hz
Power supply2AA alkaline batteries
BatteryLR6 AA alkaline battery
Operating temperature-20°C to 60°C
Storage temperature-40°C to 85°C
Dimension25 x 195mm
Weight165g (without battery)















China Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification supplier

Fiber Fault Identification VFL HCW-325 50MW High Voltage Cable Fault Locator Visual Fiber Fault Identification