Relay Protection Tester
Gas Relay Calibrator With Integrated Design And High Degree
The ZX-RLC gas relay calibrator adopts an integrated design. The
device is embedded with a full-color capacitive touch display and a
wireless keyboard and mouse.
It can easily and intuitively perform related operations on the
flow rate, volume, and seal detection of the system, and
simultaneously edit and print the related test report, and can save
the data for reading and printing at any time.
This product adopts a single-pipe structure design, which greatly
reduces the volume and cost of the three-pipe equipment. Embedded
integrated design, friendly operation interface, high degree of
automation of the whole machine.
Features
1. Acquisition system: advanced CAN bus architecture is adopted for
upper and lower computer communication, which improves the response
time of high-speed data acquisition and the service life of the
acquisition system. There are three pairs of heavy gas flow rate
and light gas volume sampling nodes, which can complete the
sampling of three nodes in one test project and display the status
of the three nodes.
2. Pipeline structure: 80-caliber main detection pipeline is
adopted, with 25-caliber and 50-caliber tapered pipe structures,
flowmeters and relays are provided with straight flow straight
sections, and the front 8D and 5D can meet the relevant fluid
standards.
3. Flow rate part: A vector frequency converter is used to control
the circulating oil flow of the centrifugal oil pump, which reduces
the pulsating flow to the flowmeter and the relay when the oil pump
is output, and improves the stability of the oil flow. Adopt 25 and
50 flowmeter pulse output high-speed frequency measurement, 25
flowmeter to detect the flow rate of 25 caliber relay, 50 flowmeter
to detect the flow rate of 50 and 80 caliber relay (V = Qv / S (V =
flow rate; Qv = flow rate; S = pipe cut Area), thereby improving
the accuracy of flow rate detection.
4. Volume part: Adopt the pulse counting of the gear metering pump,
control the motor speed of the metering pump through the analog
output signal, accurately record the number of pulses, and improve
the volume detection accuracy and detection range.
5. Pressure part: The centrifugal oil pump is used to apply the oil
pressure by blocking rotation, and the pressure transmitter analog
output is sampled.
6. Clamping part: adopts unilateral suspension centering hydraulic
automatic clamping mechanism, the concentric deviation is less than
± 3mm, which greatly reduces the clamping work intensity.
7. Human-computer interaction: The integrated design is adopted.
The device is embedded with a full-color capacitive touch display
and a wireless keyboard and mouse. It can easily and intuitively
perform related operations on the flow rate, volume, and seal
detection of the system, and edit and print the related detection
report at the same time. Data can be saved for reading and printing
at any time.
Technical Indicators
1. Measuring range
(1) Detection of heavy gas flow rate
Flow velocity range of φ25mm pipe diameter: 0.6 ~ 4.2m / s;
Flow velocity range of φ50 mm pipe diameter: 0.6 ~ 3.2m / s;
The flow velocity range of φ80mm pipe diameter: 0.6 ~ 2.2m / s.
(2) Light gas volume detection
Detection range: 0 ~ 950mL.
(3) Seal detection pressure and time range
Seal detection pressure range: 0 ~ 250kPa;
Seal detection time range: 1 ~ 60min.
(4) QJ-40 relay detection
Detection range: 1mm-150mm.
2. Precision
(1) Flow rate detection accuracy: 1.5 grades, flowmeter accuracy:
0.5 grades, heavy gas flow velocity display digits: 0.00m / s;
(2) Digits of light gas volume display: 0.0mL, accuracy: 1.0%;
(3) Sealed display digits: 0.0kPa, accuracy: 0.5%;
(4) QJ-40 display digits: 0.0mm, accuracy: 1.0 level.