Monitoring Phase Over Under 48 Volt Dc Voltage Regulator Relay Low Voltage Protection

Brand Name:GINRI
Certification:CE
Model Number:DVRD
Minimum Order Quantity:10Pcs
Delivery Time:5-8 working days
Payment Terms:L/C, T/T, Western Union,paypal
Contact Now

Add to Cart

Active Member
Address: No.337,Kaichuang Road,Baitawang Industrial Distrit, Beibaixiang Town,Yueqing City,Zhejiang Province,China
Supplier`s last login times: within 47 hours
Product Details Company Profile
Product Details

GINRI Voltage Monitoring Relay DC Over/Under Voltage Relay DVRD


Features:

  • Compact modular size
  • DC circuit monitoring of over-and undervoltage
  • Adjustable over-and undervoltage threshold
  • Adjustable trip delay time
  • Powered by the measuring circuit
  • 2C/O contacts
  • 2 LEDs for status indication

Protective Functions

  • DC overvoltage
  • DC undervoltage

Applications

  • DC cabinet
  • Battery
  • Electric control system

ModelDVRD
Input circiut =measuring circuitDC supply
Rated voltageDC12V.DC24V.DC36V,DC48V
Monitoring functionsOvervoltage,undervoltage
Voltage setting range
Rated voltageundervoltageovervolatge
DC12V10-14V13-17V
DC24V20-28V26-34V
DC36V30-42V39-51V
DC48V40-56V52-68V

Tripping delay time0.1~15s adjustable
Voltage hysteresis3-5% fixed
Reset delay time100ms
indicatorsnormal,trip
Output contacts2C/O
Contact capacity6A,250VAC/30VDC(resistive load)
Degree of protectionIP20
Working conditions-25℃~65℃,≤85%RH,non-condensing

Mechanical

durability

1000000 cycles
Dielectric strength>2KVAC 1min
Weight130g
Dimension(HXWXD)79X23X79mm
MountingDin rail

Low voltage protection
Also known as loss of voltage protection and undervoltage protection. A protection measure that automatically disconnects the circuit when the supply voltage disappears or falls below a certain value. Its function is to avoid accidents caused by the sudden start of the device when the voltage is restored; and to avoid damage due to the bare operation at low voltage. At low voltage, the equipment can only maintain its operation when the current is increased. The current increases, and the heating temperature is naturally intensified. If it is light, it will damage the equipment and cause fire. For important protection objects, the device consists of voltage relays, time relays and circuit breakers, and the protection performance is relatively accurate. For general low-voltage equipment, common fuses, contactors and loss-of-voltage (undervoltage) trip units are used as protection devices. [1]
Low voltage protection means that the low voltage protection relay is connected in parallel at both ends of the power supply. When the voltage is low, it will automatically trip to separate the circuit breaker switch. Low-voltage internship installation: low-voltage equipment such as thermal relays, fuses, and intermediate relays.
When the voltage of the power supply bus of the motor is reduced or interrupted and restored, the low voltage protection is usually installed on the secondary motor to prevent the motor from being automatically started at the same time. When the power supply bus voltage is low to a certain value, the low voltage protection action removes the secondary motor and restores the power supply bus voltage to a sufficient voltage to ensure the self-starting of the important motor.