Add to Cart
The use of mixer
1. Before use, an empty test machine shall be used. Before the test
machine, the firmness of all the connecting parts of the machine
table shall be checked first, especially if the bearing part is
loose during transportation, the main switch is closed, and the
power supply is conducted.
2. Empty test machine test. The mixer was put into production only
when abnormal sounds, high temperature of bearing gears, and other
undesirable phenomena were not found.
3. If abnormal vibrations or strange sounds are detected during
use, stop the mixer and perform a thorough inspection.
4. The load should not be too large. It is generally measured by
the load of the motor. The load current of the 380V motor when
stirring the material should not exceed 6 amps. If it exceeds the
load, the stirring capacity should be reduced immediately.
5. The management personnel must be familiar with the technical
performance, internal structure, control structure, and use
principle of the mixer. Do not leave the workplace during operation
to prevent malfunctions and damage to mechanical parts, so as to
ensure safe production.
Principle of Motion: Mixing with no hidden corners in the mixing
pan by installing mixing tools and scraper tools on a specially
designed drive system. The mixing track as follows.
Ceramic Materials Precast Concrete Mixer Durable Tool PMC4000
Performance Characteristics
1) Low Energy Consumption, 30% to 50% reduced comparing same
capacity mixers!
2) High Homogenization up to 97-99%!
3) Short Mixing Time as 1-3min!
4) Simple Structure, Simple and Convenient Maintenance
5) Flexible Layout, 1-3 unloading doors are optional for different
production lines.
6) Compact Structure and Small Space required
Temperature and moisture sensor
To ensure concrete and prefabricated parts quality, sensors of
temperature and moisture made in Bikotronic of German can be
selected
Hydraulic Coupling
High Pressure Washing System
Control system
The control system can automatically control the process of dosing,
mixing, and discharging.
Spare parts
Spare parts can be supplied at any time.
Technical Specification | ||||||||||||||
ITEM/(PMC) | PMC | PMC | PMC | PMC | PMC | PMC | PMC | PMC | PMC | PMC | PMC | PMC | PMC | PMC 4000 |
Feeding Capacity (L) | 75 | 150 | 225 | 375 | 500 | 750 | 1125 | 1500 | 1875 | 2250 | 3000 | 3750 | 4500 | 6000 |
Output Capacity (L) | 50 | 100 | 150 | 250 | 330 | 500 | 750 | 1000 | 1250 | 1500 | 2000 | 2500 | 3000 | 4000 |
Feeding Weight (kg) | 120 | 240 | 360 | 600 | 800 | 1200 | 1800 | 2400 | 3000 | 3600 | 4800 | 6000 | 7200 | 9600 |
Mixing Power (kw) | 3 | 5.5 | 7.5 | 11 | 15 | 18.5 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 |
Discharging Power (kw) | Pneumatic Discharge(Hydraulic Discharge Optional) | 3 | 3 | 3 | 4 | 4 | 4 | 4 | ||||||
Mixing Star*Blade | 1*2 | 1*2 | 1*2 | 1*2 | 1*2 | 1*2 | 1*3 | 2*2 | 2*2 | 2*2 | 3*2 | 3*3 | 3*3 | 3*3 |
Side Scraper | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Discharge Scraper | - | - | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 |
Weight (kg) | 750 | 1000 | 1300 | 1500 | 2000 | 2400 | 3900 | 5500 | 6000 | 6500 | 9200 | 11000 | 12000 | 17500 |
Lifting Power (kw) | - | - | - | 3 | 4 | 4 | 7.5 | 11 | 11 | 15 | 18.5 | 22 | 30 | - |
Dimension (L*W*H) mm | 950* | 1664* | 1670* | 1860* | 1870* | 2230* | 2580* | 2891* | 3058* | 3223* | 3625* | 3893* | 3893* | 4594* |