5000hrs Insulators Reliability Testing Machine IEC62217-2012

Brand Name:DAXIAN
Certification:IEC62730-2024、IECIEC62217-2012
Model Number:DX8428
Minimum Order Quantity:1 set
Delivery Time:8-10 work days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No.168 Zhen'an West Road Changlian Industry Mansion Xiabian Community Dongguan China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

IEC62730-2024,IEC62217-2012 Polymeric Insulators 5000hrs Multiple Stress Test Machine



1. Test sample: Two test insulators of the same design with a creepage distance between 500mm and 800mm,

2. Procedure: Conduct the test in a sealed, damp, and corrosion-resistant test chamber, with a volume not exceeding 20M3. Figure B1 is a schematic diagram of this test chamber

3. Separate observation holes for wipers and movable ultraviolet filters to observe the equipment in the experiment.

4. Test conditions: As shown in Figure B2, various stress cycles are applied to the insulator, which are repeated for about 5000 hours. During the equipment cycle test, the test sample should be subjected to temperature changes and condensation.

5. As shown in Figure B3, the test is installed vertically in the middle of the test, with a minimum distance of 400mm between the adjacent umbrella edges of the test specimen and the top, as well as between the test specimen and the wall and ground Before the experiment begins, the test sample should be cleaned with deionized water,

7. Up to three pairs of samples with similar creepage distances can be tested simultaneously

8. Voltage: The value obtained by dividing the creepage distance of the test sample (in mm) by 34.6 (equivalent to a creepage distance of 20mm/KV, calculated based on the phase to phase voltage)

9. For the power circuit, when the continuous negative current load is 250mA (r.m.s), the maximum voltage drop on the high voltage side during 1 second should not exceed 5%, and the protection level should be adjusted to 1A (r.m.s)

10. Sunlight simulation: The simulated solar radiation is provided by a xenon arc lamp with a nominal output of 6500W and equipped with two borosilicate glass filters (see example B.4), with a distance of approximately 480mm between the xenon arc lamp and the test sample

11. At the beginning of each experiment, a new lamp and filter should be used. During the experiment, when replacing the filter (and if the lamp is also necessary), it should be done according to the recommendation of the lamp manufacturer.

DX8428 Insulator Multi Stress Testing Machine.pdf




Welcome to visit our factory for sightseeing!


Supplier Company NameDaxian Instrument Equipment CO.,Limited
Company AddressChanglian Industrial Building, 168 Zhenan West Road, Xiabian Community, Chang'an Town, Dongguan, Guang Dong, China
Contact PersonSophia Su
Mobile Number86-13266221899
Telephone Number86-0769-82759287
China 5000hrs Insulators Reliability Testing Machine IEC62217-2012 supplier

5000hrs Insulators Reliability Testing Machine IEC62217-2012

Inquiry Cart 0